    In this paper, a new readout method for a 2-D cross-point resistive sensor array with an opamp-less interface circuit is proposed. To avoid the readout inaccuracy caused by nonidealities of an opamp in the conventional readout circuit, our proposed circuit does not use any opamps. A switch resistance calibration technique is also proposed to remove effectively the negative effects of switch nonidealities, which bring high readout accuracy and wide scalability of a target resistive array. To evaluate the readout accuracy in the proposed method, simulation is carried out and the readout error less than 0.06% with 16-bit ADCs in 32×32 resistive array is achieved.

    Original languageEnglish
    Title of host publicationProceedings - APCCAS 2019
    Subtitle of host publication2019 IEEE Asia Pacific Conference on Circuits and Systems: Innovative CAS Towards Sustainable Energy and Technology Disruption
    PublisherInstitute of Electrical and Electronics Engineers Inc.
    Pages105-108
    Number of pages4
    ISBN (Electronic)9781728129402
    DOIs
    Publication statusPublished - 2019 Nov
    Event15th Annual IEEE Asia Pacific Conference on Circuits and Systems, APCCAS 2019 - Bangkok, Thailand
    Duration: 2019 Nov 112019 Nov 14

    Publication series

    NameProceedings - APCCAS 2019: 2019 IEEE Asia Pacific Conference on Circuits and Systems: Innovative CAS Towards Sustainable Energy and Technology Disruption

    Conference

    Conference15th Annual IEEE Asia Pacific Conference on Circuits and Systems, APCCAS 2019
    CountryThailand
    CityBangkok
    Period19/11/1119/11/14

    Keywords

    • 2-D resistive array
    • interface circuit
    • olfactory sensing
    • opamp-less
    • sneak current
    • switch resistance calibration

    ASJC Scopus subject areas

    • Energy Engineering and Power Technology
    • Renewable Energy, Sustainability and the Environment
    • Electrical and Electronic Engineering
    • Electronic, Optical and Magnetic Materials
    • Instrumentation

    Fingerprint Dive into the research topics of 'A High Accuracy Opamp-less Interface Circuit for 2-D Cross-Point Resistive Sensor Array with Switch Resistance Calibration'. Together they form a unique fingerprint.

  • Cite this

    Shiiki, Y., & Ishikuro, H. (2019). A High Accuracy Opamp-less Interface Circuit for 2-D Cross-Point Resistive Sensor Array with Switch Resistance Calibration. In Proceedings - APCCAS 2019: 2019 IEEE Asia Pacific Conference on Circuits and Systems: Innovative CAS Towards Sustainable Energy and Technology Disruption (pp. 105-108). [8953148] (Proceedings - APCCAS 2019: 2019 IEEE Asia Pacific Conference on Circuits and Systems: Innovative CAS Towards Sustainable Energy and Technology Disruption). Institute of Electrical and Electronics Engineers Inc.. https://doi.org/10.1109/APCCAS47518.2019.8953148