A micro planar coil for local high resolution magnetic resonance imaging

Hidetoshi Takahashi, Tetsuji Dohi, Kiyoshi Matsumoto, Isao Shimoyama

Research output: Chapter in Book/Report/Conference proceedingConference contribution

14 Citations (Scopus)

Abstract

This paper reports on a flexible micro planar coil for an MR (Magnetic Resonance) catheter. High resolution images can be obtained by using the MR catheter. Two types of coils of 5 mm and 20 mm in diameter were fabricated. Both of the coils were designed to have inductance of 1.0 μH at 8.5 MHz. The proto-type MR catheters were made by attaching the micro coils to the tip of acrylic pipes. In order to evaluate the MR catheters, the sensitive area and SNR (Signal to Noise Ratio) were measured. SNRs of the MR catheters were about three to eight times higher than that of a standard medical coil. Furthermore, we demonstrated that high resolution MR images can be achieved by using the MR catheters. MR images of a gumbo (Abelmoschus esculentus) were acquired with 0.5 × 0.5 × 1.0 mm3 resolution. While clear MR images were not able to be taken by the standard medical coil due to its low SNR, we were able to observe the gumbo and distinguished its seeds one by one in the MR images taken by the MR catheters.

Original languageEnglish
Title of host publicationProceedings - CIS Workshops 2007, 2007 International Conference on Computational Intelligence and Security Workshops, CISW 2007
Pages549-552
Number of pages4
Publication statusPublished - 2007 Dec 1
Externally publishedYes
Event20th IEEE International Conference on Micro Electro Mechanical Systems, MEMS 2007 - Kobe, Japan
Duration: 2007 Jan 212007 Jan 25

Publication series

NameProceedings of the IEEE International Conference on Micro Electro Mechanical Systems (MEMS)
ISSN (Print)1084-6999

Other

Other20th IEEE International Conference on Micro Electro Mechanical Systems, MEMS 2007
CountryJapan
CityKobe
Period07/1/2107/1/25

Fingerprint

Magnetic resonance
magnetic resonance
coils
Catheters
Imaging techniques
high resolution
Signal to noise ratio
signal to noise ratios
Image resolution
inductance
Inductance
Acrylics
Seed
seeds
Pipe

ASJC Scopus subject areas

  • Electronic, Optical and Magnetic Materials
  • Condensed Matter Physics
  • Mechanical Engineering
  • Electrical and Electronic Engineering

Cite this

Takahashi, H., Dohi, T., Matsumoto, K., & Shimoyama, I. (2007). A micro planar coil for local high resolution magnetic resonance imaging. In Proceedings - CIS Workshops 2007, 2007 International Conference on Computational Intelligence and Security Workshops, CISW 2007 (pp. 549-552). [4433156] (Proceedings of the IEEE International Conference on Micro Electro Mechanical Systems (MEMS)).

A micro planar coil for local high resolution magnetic resonance imaging. / Takahashi, Hidetoshi; Dohi, Tetsuji; Matsumoto, Kiyoshi; Shimoyama, Isao.

Proceedings - CIS Workshops 2007, 2007 International Conference on Computational Intelligence and Security Workshops, CISW 2007. 2007. p. 549-552 4433156 (Proceedings of the IEEE International Conference on Micro Electro Mechanical Systems (MEMS)).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Takahashi, H, Dohi, T, Matsumoto, K & Shimoyama, I 2007, A micro planar coil for local high resolution magnetic resonance imaging. in Proceedings - CIS Workshops 2007, 2007 International Conference on Computational Intelligence and Security Workshops, CISW 2007., 4433156, Proceedings of the IEEE International Conference on Micro Electro Mechanical Systems (MEMS), pp. 549-552, 20th IEEE International Conference on Micro Electro Mechanical Systems, MEMS 2007, Kobe, Japan, 07/1/21.
Takahashi H, Dohi T, Matsumoto K, Shimoyama I. A micro planar coil for local high resolution magnetic resonance imaging. In Proceedings - CIS Workshops 2007, 2007 International Conference on Computational Intelligence and Security Workshops, CISW 2007. 2007. p. 549-552. 4433156. (Proceedings of the IEEE International Conference on Micro Electro Mechanical Systems (MEMS)).
Takahashi, Hidetoshi ; Dohi, Tetsuji ; Matsumoto, Kiyoshi ; Shimoyama, Isao. / A micro planar coil for local high resolution magnetic resonance imaging. Proceedings - CIS Workshops 2007, 2007 International Conference on Computational Intelligence and Security Workshops, CISW 2007. 2007. pp. 549-552 (Proceedings of the IEEE International Conference on Micro Electro Mechanical Systems (MEMS)).
@inproceedings{323ac46ab7ef4b128870784f91c736de,
title = "A micro planar coil for local high resolution magnetic resonance imaging",
abstract = "This paper reports on a flexible micro planar coil for an MR (Magnetic Resonance) catheter. High resolution images can be obtained by using the MR catheter. Two types of coils of 5 mm and 20 mm in diameter were fabricated. Both of the coils were designed to have inductance of 1.0 μH at 8.5 MHz. The proto-type MR catheters were made by attaching the micro coils to the tip of acrylic pipes. In order to evaluate the MR catheters, the sensitive area and SNR (Signal to Noise Ratio) were measured. SNRs of the MR catheters were about three to eight times higher than that of a standard medical coil. Furthermore, we demonstrated that high resolution MR images can be achieved by using the MR catheters. MR images of a gumbo (Abelmoschus esculentus) were acquired with 0.5 × 0.5 × 1.0 mm3 resolution. While clear MR images were not able to be taken by the standard medical coil due to its low SNR, we were able to observe the gumbo and distinguished its seeds one by one in the MR images taken by the MR catheters.",
author = "Hidetoshi Takahashi and Tetsuji Dohi and Kiyoshi Matsumoto and Isao Shimoyama",
year = "2007",
month = "12",
day = "1",
language = "English",
isbn = "1424409519",
series = "Proceedings of the IEEE International Conference on Micro Electro Mechanical Systems (MEMS)",
pages = "549--552",
booktitle = "Proceedings - CIS Workshops 2007, 2007 International Conference on Computational Intelligence and Security Workshops, CISW 2007",

}

TY - GEN

T1 - A micro planar coil for local high resolution magnetic resonance imaging

AU - Takahashi, Hidetoshi

AU - Dohi, Tetsuji

AU - Matsumoto, Kiyoshi

AU - Shimoyama, Isao

PY - 2007/12/1

Y1 - 2007/12/1

N2 - This paper reports on a flexible micro planar coil for an MR (Magnetic Resonance) catheter. High resolution images can be obtained by using the MR catheter. Two types of coils of 5 mm and 20 mm in diameter were fabricated. Both of the coils were designed to have inductance of 1.0 μH at 8.5 MHz. The proto-type MR catheters were made by attaching the micro coils to the tip of acrylic pipes. In order to evaluate the MR catheters, the sensitive area and SNR (Signal to Noise Ratio) were measured. SNRs of the MR catheters were about three to eight times higher than that of a standard medical coil. Furthermore, we demonstrated that high resolution MR images can be achieved by using the MR catheters. MR images of a gumbo (Abelmoschus esculentus) were acquired with 0.5 × 0.5 × 1.0 mm3 resolution. While clear MR images were not able to be taken by the standard medical coil due to its low SNR, we were able to observe the gumbo and distinguished its seeds one by one in the MR images taken by the MR catheters.

AB - This paper reports on a flexible micro planar coil for an MR (Magnetic Resonance) catheter. High resolution images can be obtained by using the MR catheter. Two types of coils of 5 mm and 20 mm in diameter were fabricated. Both of the coils were designed to have inductance of 1.0 μH at 8.5 MHz. The proto-type MR catheters were made by attaching the micro coils to the tip of acrylic pipes. In order to evaluate the MR catheters, the sensitive area and SNR (Signal to Noise Ratio) were measured. SNRs of the MR catheters were about three to eight times higher than that of a standard medical coil. Furthermore, we demonstrated that high resolution MR images can be achieved by using the MR catheters. MR images of a gumbo (Abelmoschus esculentus) were acquired with 0.5 × 0.5 × 1.0 mm3 resolution. While clear MR images were not able to be taken by the standard medical coil due to its low SNR, we were able to observe the gumbo and distinguished its seeds one by one in the MR images taken by the MR catheters.

UR - http://www.scopus.com/inward/record.url?scp=50049110071&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=50049110071&partnerID=8YFLogxK

M3 - Conference contribution

AN - SCOPUS:50049110071

SN - 1424409519

SN - 9781424409518

T3 - Proceedings of the IEEE International Conference on Micro Electro Mechanical Systems (MEMS)

SP - 549

EP - 552

BT - Proceedings - CIS Workshops 2007, 2007 International Conference on Computational Intelligence and Security Workshops, CISW 2007

ER -