A new hydrodynamic oscillator type flowmeter.

S. Honda, H. Yamasaki

Research output: Chapter in Book/Report/Conference proceedingChapter

1 Citation (Scopus)

Abstract

Both vortex flowmeters and fluidic flowmeters form a family of the hydrodynamic oscillator type which have geometrical and hydrodynamic complementarity. The objectives of this study were to propose a new hydrodynamic oscillator type flowmeter and to promote a unified approach to these flowmeters. Proposed flowmeters consist of a main nozzle and a bluff cylinder, so called target, which was derived from feedback oscillator type fluidic flowmeters by eliminating both side walls based on a topological isomorphism between fluidic flowmeters and vortex flowmeters. The rangeability of the proposed flowmeter appeared comparable to the original fluidic flowmeter. (A)

Original languageEnglish
Title of host publicationIN: FLUID CONTROL AND MEASUREMENT, (TOKYO, JAPAN: SEP. 2-6, 1985), M. HARADA (ED.)
PublisherPergamon Press
Volume2 , Oxford, U.K., Pergamon Press, 1986, p.623-628.
ISBN (Print)0 08 031681 6
Publication statusPublished - 1986
Externally publishedYes

Fingerprint

Flowmeters
Hydrodynamics
Fluidics
Vortex flow
Nozzles
Feedback

ASJC Scopus subject areas

  • Engineering(all)

Cite this

Honda, S., & Yamasaki, H. (1986). A new hydrodynamic oscillator type flowmeter. In IN: FLUID CONTROL AND MEASUREMENT, (TOKYO, JAPAN: SEP. 2-6, 1985), M. HARADA (ED.) (Vol. 2 , Oxford, U.K., Pergamon Press, 1986, p.623-628.). Pergamon Press.

A new hydrodynamic oscillator type flowmeter. / Honda, S.; Yamasaki, H.

IN: FLUID CONTROL AND MEASUREMENT, (TOKYO, JAPAN: SEP. 2-6, 1985), M. HARADA (ED.). Vol. 2 , Oxford, U.K., Pergamon Press, 1986, p.623-628. Pergamon Press, 1986.

Research output: Chapter in Book/Report/Conference proceedingChapter

Honda, S & Yamasaki, H 1986, A new hydrodynamic oscillator type flowmeter. in IN: FLUID CONTROL AND MEASUREMENT, (TOKYO, JAPAN: SEP. 2-6, 1985), M. HARADA (ED.). vol. 2 , Oxford, U.K., Pergamon Press, 1986, p.623-628., Pergamon Press.
Honda S, Yamasaki H. A new hydrodynamic oscillator type flowmeter. In IN: FLUID CONTROL AND MEASUREMENT, (TOKYO, JAPAN: SEP. 2-6, 1985), M. HARADA (ED.). Vol. 2 , Oxford, U.K., Pergamon Press, 1986, p.623-628. Pergamon Press. 1986
Honda, S. ; Yamasaki, H. / A new hydrodynamic oscillator type flowmeter. IN: FLUID CONTROL AND MEASUREMENT, (TOKYO, JAPAN: SEP. 2-6, 1985), M. HARADA (ED.). Vol. 2 , Oxford, U.K., Pergamon Press, 1986, p.623-628. Pergamon Press, 1986.
@inbook{7e11fd40b0844cd98138d83a0d12bc58,
title = "A new hydrodynamic oscillator type flowmeter.",
abstract = "Both vortex flowmeters and fluidic flowmeters form a family of the hydrodynamic oscillator type which have geometrical and hydrodynamic complementarity. The objectives of this study were to propose a new hydrodynamic oscillator type flowmeter and to promote a unified approach to these flowmeters. Proposed flowmeters consist of a main nozzle and a bluff cylinder, so called target, which was derived from feedback oscillator type fluidic flowmeters by eliminating both side walls based on a topological isomorphism between fluidic flowmeters and vortex flowmeters. The rangeability of the proposed flowmeter appeared comparable to the original fluidic flowmeter. (A)",
author = "S. Honda and H. Yamasaki",
year = "1986",
language = "English",
isbn = "0 08 031681 6",
volume = "2 , Oxford, U.K., Pergamon Press, 1986, p.623-628.",
booktitle = "IN: FLUID CONTROL AND MEASUREMENT, (TOKYO, JAPAN: SEP. 2-6, 1985), M. HARADA (ED.)",
publisher = "Pergamon Press",

}

TY - CHAP

T1 - A new hydrodynamic oscillator type flowmeter.

AU - Honda, S.

AU - Yamasaki, H.

PY - 1986

Y1 - 1986

N2 - Both vortex flowmeters and fluidic flowmeters form a family of the hydrodynamic oscillator type which have geometrical and hydrodynamic complementarity. The objectives of this study were to propose a new hydrodynamic oscillator type flowmeter and to promote a unified approach to these flowmeters. Proposed flowmeters consist of a main nozzle and a bluff cylinder, so called target, which was derived from feedback oscillator type fluidic flowmeters by eliminating both side walls based on a topological isomorphism between fluidic flowmeters and vortex flowmeters. The rangeability of the proposed flowmeter appeared comparable to the original fluidic flowmeter. (A)

AB - Both vortex flowmeters and fluidic flowmeters form a family of the hydrodynamic oscillator type which have geometrical and hydrodynamic complementarity. The objectives of this study were to propose a new hydrodynamic oscillator type flowmeter and to promote a unified approach to these flowmeters. Proposed flowmeters consist of a main nozzle and a bluff cylinder, so called target, which was derived from feedback oscillator type fluidic flowmeters by eliminating both side walls based on a topological isomorphism between fluidic flowmeters and vortex flowmeters. The rangeability of the proposed flowmeter appeared comparable to the original fluidic flowmeter. (A)

UR - http://www.scopus.com/inward/record.url?scp=0022528276&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0022528276&partnerID=8YFLogxK

M3 - Chapter

AN - SCOPUS:0022528276

SN - 0 08 031681 6

VL - 2 , Oxford, U.K., Pergamon Press, 1986, p.623-628.

BT - IN: FLUID CONTROL AND MEASUREMENT, (TOKYO, JAPAN: SEP. 2-6, 1985), M. HARADA (ED.)

PB - Pergamon Press

ER -