The energy of interface adhesion between two elastic-plastic materials was directly evaluated as the mechanical work supplied exclusively to separate the interface. Interface crack extension was simulated by elastic plastic finite element models, where the nodes along the interface in the vicinity of crack tip were divided into two nodes and the nodal forces were gradually decreased to zero. While further plastic deformation takes place in the volume of materials during crack extension, the work done by these nodal forces against mutual displacement of crack surfaces should be consumed on the surfaces and thus equals to the interface adhesion energy. This technique was applied to a copper/polyimide system for flexible printed circuits in accordance with the new experimental results. In comparison to the results obtained by the conventional peel test, this technique yielded far smaller amount of interface energy successfully excluding the energy dissipated with bulk plastic deformation without any insertion of cohesive strip along the interface in the model.

Original languageEnglish
Pages (from-to)5007-5017
Number of pages11
JournalEngineering Fracture Mechanics
Volume75
Issue number18
DOIs
Publication statusPublished - 2008 Dec

Fingerprint

Dissimilar materials
Bond strength (materials)
Cracks
Plastic deformation
Adhesion
Plastics
Printed circuits
Polyimides
Crack tips
Copper

Keywords

  • Adhesion
  • Energy
  • Flexible printed circuit
  • Interface
  • Strength

ASJC Scopus subject areas

  • Mechanical Engineering
  • Mechanics of Materials
  • Materials Science(all)

Cite this

A novel evaluation method for interfacial adhesion strength in ductile dissimilar materials. / Kamiya, Shoji; Furuta, Harunori; Omiya, Masaki; Shimomura, Hiroshi.

In: Engineering Fracture Mechanics, Vol. 75, No. 18, 12.2008, p. 5007-5017.

Research output: Contribution to journalArticle

Kamiya, Shoji ; Furuta, Harunori ; Omiya, Masaki ; Shimomura, Hiroshi. / A novel evaluation method for interfacial adhesion strength in ductile dissimilar materials. In: Engineering Fracture Mechanics. 2008 ; Vol. 75, No. 18. pp. 5007-5017.
@article{04523d62a5154170806b3bd078ee337e,
title = "A novel evaluation method for interfacial adhesion strength in ductile dissimilar materials",
abstract = "The energy of interface adhesion between two elastic-plastic materials was directly evaluated as the mechanical work supplied exclusively to separate the interface. Interface crack extension was simulated by elastic plastic finite element models, where the nodes along the interface in the vicinity of crack tip were divided into two nodes and the nodal forces were gradually decreased to zero. While further plastic deformation takes place in the volume of materials during crack extension, the work done by these nodal forces against mutual displacement of crack surfaces should be consumed on the surfaces and thus equals to the interface adhesion energy. This technique was applied to a copper/polyimide system for flexible printed circuits in accordance with the new experimental results. In comparison to the results obtained by the conventional peel test, this technique yielded far smaller amount of interface energy successfully excluding the energy dissipated with bulk plastic deformation without any insertion of cohesive strip along the interface in the model.",
keywords = "Adhesion, Energy, Flexible printed circuit, Interface, Strength",
author = "Shoji Kamiya and Harunori Furuta and Masaki Omiya and Hiroshi Shimomura",
year = "2008",
month = "12",
doi = "10.1016/j.engfracmech.2008.06.011",
language = "English",
volume = "75",
pages = "5007--5017",
journal = "Engineering Fracture Mechanics",
issn = "0013-7944",
publisher = "Elsevier BV",
number = "18",

}

TY - JOUR

T1 - A novel evaluation method for interfacial adhesion strength in ductile dissimilar materials

AU - Kamiya, Shoji

AU - Furuta, Harunori

AU - Omiya, Masaki

AU - Shimomura, Hiroshi

PY - 2008/12

Y1 - 2008/12

N2 - The energy of interface adhesion between two elastic-plastic materials was directly evaluated as the mechanical work supplied exclusively to separate the interface. Interface crack extension was simulated by elastic plastic finite element models, where the nodes along the interface in the vicinity of crack tip were divided into two nodes and the nodal forces were gradually decreased to zero. While further plastic deformation takes place in the volume of materials during crack extension, the work done by these nodal forces against mutual displacement of crack surfaces should be consumed on the surfaces and thus equals to the interface adhesion energy. This technique was applied to a copper/polyimide system for flexible printed circuits in accordance with the new experimental results. In comparison to the results obtained by the conventional peel test, this technique yielded far smaller amount of interface energy successfully excluding the energy dissipated with bulk plastic deformation without any insertion of cohesive strip along the interface in the model.

AB - The energy of interface adhesion between two elastic-plastic materials was directly evaluated as the mechanical work supplied exclusively to separate the interface. Interface crack extension was simulated by elastic plastic finite element models, where the nodes along the interface in the vicinity of crack tip were divided into two nodes and the nodal forces were gradually decreased to zero. While further plastic deformation takes place in the volume of materials during crack extension, the work done by these nodal forces against mutual displacement of crack surfaces should be consumed on the surfaces and thus equals to the interface adhesion energy. This technique was applied to a copper/polyimide system for flexible printed circuits in accordance with the new experimental results. In comparison to the results obtained by the conventional peel test, this technique yielded far smaller amount of interface energy successfully excluding the energy dissipated with bulk plastic deformation without any insertion of cohesive strip along the interface in the model.

KW - Adhesion

KW - Energy

KW - Flexible printed circuit

KW - Interface

KW - Strength

UR - http://www.scopus.com/inward/record.url?scp=54949125287&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=54949125287&partnerID=8YFLogxK

U2 - 10.1016/j.engfracmech.2008.06.011

DO - 10.1016/j.engfracmech.2008.06.011

M3 - Article

AN - SCOPUS:54949125287

VL - 75

SP - 5007

EP - 5017

JO - Engineering Fracture Mechanics

JF - Engineering Fracture Mechanics

SN - 0013-7944

IS - 18

ER -