A novel infrared laser device that measures multilateral parameters of stepping performance for assessment of all risk in elderly individuals

Shu Nishiguchi, Minoru Yamada, Kazuki Uemura, Tetsuya Matsumura, Masaki Takahashi, Toshiki Moriguchi, Tomoki Aoyama

Research output: Contribution to journalArticle

13 Citations (Scopus)

Abstract

Background and aims: Avoiding falls requires fast and appropriate step responses in real-life situations. We developed a step-tracking device that uses an infrared laser sensor for convenient assessment of stepping performance, including concurrent assessment of temporal and spatial parameters. In the present study, we created a new index for assessment of fall risk that uses step speed and accuracy measurements. The purpose of this study was to determine whether the new index could discriminate between elderly individuals with different risks of falling. Methods: One hundred and fifty-two community-dwelling elderly individuals (73.9 ± 4.6 years) participated and performed stepping tasks as quickly as possible on a plus-shaped mat in response to optical cues. The step-tracking device with the infrared sensor detected the motion and position of both legs in the step field. The device recorded temporal and spatial parameters, foot-off and foot-contact time, step length, and the percentage of correctly executed steps. We used the coefficients of a logistic regression model to develop "stepping-response score" based on the weighted sum of these temporal and spatial parameters. Results: The faller group had significantly worse stepping-response score than the non-faller group (p < 0.001). A stepwise logistic regression analysis demonstrated that stepping-response score was independently associated with falling (odds ratio = 0.15; p < 0.001). The ROC curve had a moderate AUC (0.73) for stepping-response score (sensitivity 73.0 %; specificity 69.7 %). Conclusions: This study indicates that the stepping-response score calculated from measurements obtained using the new step-tracking device can identify elderly individuals who are at a risk of falling.

Original languageEnglish
Pages (from-to)311-316
Number of pages6
JournalAging clinical and experimental research
Volume25
Issue number3
DOIs
Publication statusPublished - 2013

Fingerprint

Accidental Falls
Lasers
Equipment and Supplies
Logistic Models
Foot
Independent Living
ROC Curve
Area Under Curve
Cues
Leg
Odds Ratio
Regression Analysis

Keywords

  • Elderly
  • Falls
  • Laser range finder
  • Step-tracking device
  • Stepping performance

ASJC Scopus subject areas

  • Ageing
  • Geriatrics and Gerontology
  • Medicine(all)

Cite this

A novel infrared laser device that measures multilateral parameters of stepping performance for assessment of all risk in elderly individuals. / Nishiguchi, Shu; Yamada, Minoru; Uemura, Kazuki; Matsumura, Tetsuya; Takahashi, Masaki; Moriguchi, Toshiki; Aoyama, Tomoki.

In: Aging clinical and experimental research, Vol. 25, No. 3, 2013, p. 311-316.

Research output: Contribution to journalArticle

Nishiguchi, Shu ; Yamada, Minoru ; Uemura, Kazuki ; Matsumura, Tetsuya ; Takahashi, Masaki ; Moriguchi, Toshiki ; Aoyama, Tomoki. / A novel infrared laser device that measures multilateral parameters of stepping performance for assessment of all risk in elderly individuals. In: Aging clinical and experimental research. 2013 ; Vol. 25, No. 3. pp. 311-316.
@article{d637ac2bb4344fa2a126659f047b10bb,
title = "A novel infrared laser device that measures multilateral parameters of stepping performance for assessment of all risk in elderly individuals",
abstract = "Background and aims: Avoiding falls requires fast and appropriate step responses in real-life situations. We developed a step-tracking device that uses an infrared laser sensor for convenient assessment of stepping performance, including concurrent assessment of temporal and spatial parameters. In the present study, we created a new index for assessment of fall risk that uses step speed and accuracy measurements. The purpose of this study was to determine whether the new index could discriminate between elderly individuals with different risks of falling. Methods: One hundred and fifty-two community-dwelling elderly individuals (73.9 ± 4.6 years) participated and performed stepping tasks as quickly as possible on a plus-shaped mat in response to optical cues. The step-tracking device with the infrared sensor detected the motion and position of both legs in the step field. The device recorded temporal and spatial parameters, foot-off and foot-contact time, step length, and the percentage of correctly executed steps. We used the coefficients of a logistic regression model to develop {"}stepping-response score{"} based on the weighted sum of these temporal and spatial parameters. Results: The faller group had significantly worse stepping-response score than the non-faller group (p < 0.001). A stepwise logistic regression analysis demonstrated that stepping-response score was independently associated with falling (odds ratio = 0.15; p < 0.001). The ROC curve had a moderate AUC (0.73) for stepping-response score (sensitivity 73.0 {\%}; specificity 69.7 {\%}). Conclusions: This study indicates that the stepping-response score calculated from measurements obtained using the new step-tracking device can identify elderly individuals who are at a risk of falling.",
keywords = "Elderly, Falls, Laser range finder, Step-tracking device, Stepping performance",
author = "Shu Nishiguchi and Minoru Yamada and Kazuki Uemura and Tetsuya Matsumura and Masaki Takahashi and Toshiki Moriguchi and Tomoki Aoyama",
year = "2013",
doi = "10.1007/s40520-013-0042-9",
language = "English",
volume = "25",
pages = "311--316",
journal = "Aging clinical and experimental research",
issn = "1594-0667",
publisher = "Springer Verlag",
number = "3",

}

TY - JOUR

T1 - A novel infrared laser device that measures multilateral parameters of stepping performance for assessment of all risk in elderly individuals

AU - Nishiguchi, Shu

AU - Yamada, Minoru

AU - Uemura, Kazuki

AU - Matsumura, Tetsuya

AU - Takahashi, Masaki

AU - Moriguchi, Toshiki

AU - Aoyama, Tomoki

PY - 2013

Y1 - 2013

N2 - Background and aims: Avoiding falls requires fast and appropriate step responses in real-life situations. We developed a step-tracking device that uses an infrared laser sensor for convenient assessment of stepping performance, including concurrent assessment of temporal and spatial parameters. In the present study, we created a new index for assessment of fall risk that uses step speed and accuracy measurements. The purpose of this study was to determine whether the new index could discriminate between elderly individuals with different risks of falling. Methods: One hundred and fifty-two community-dwelling elderly individuals (73.9 ± 4.6 years) participated and performed stepping tasks as quickly as possible on a plus-shaped mat in response to optical cues. The step-tracking device with the infrared sensor detected the motion and position of both legs in the step field. The device recorded temporal and spatial parameters, foot-off and foot-contact time, step length, and the percentage of correctly executed steps. We used the coefficients of a logistic regression model to develop "stepping-response score" based on the weighted sum of these temporal and spatial parameters. Results: The faller group had significantly worse stepping-response score than the non-faller group (p < 0.001). A stepwise logistic regression analysis demonstrated that stepping-response score was independently associated with falling (odds ratio = 0.15; p < 0.001). The ROC curve had a moderate AUC (0.73) for stepping-response score (sensitivity 73.0 %; specificity 69.7 %). Conclusions: This study indicates that the stepping-response score calculated from measurements obtained using the new step-tracking device can identify elderly individuals who are at a risk of falling.

AB - Background and aims: Avoiding falls requires fast and appropriate step responses in real-life situations. We developed a step-tracking device that uses an infrared laser sensor for convenient assessment of stepping performance, including concurrent assessment of temporal and spatial parameters. In the present study, we created a new index for assessment of fall risk that uses step speed and accuracy measurements. The purpose of this study was to determine whether the new index could discriminate between elderly individuals with different risks of falling. Methods: One hundred and fifty-two community-dwelling elderly individuals (73.9 ± 4.6 years) participated and performed stepping tasks as quickly as possible on a plus-shaped mat in response to optical cues. The step-tracking device with the infrared sensor detected the motion and position of both legs in the step field. The device recorded temporal and spatial parameters, foot-off and foot-contact time, step length, and the percentage of correctly executed steps. We used the coefficients of a logistic regression model to develop "stepping-response score" based on the weighted sum of these temporal and spatial parameters. Results: The faller group had significantly worse stepping-response score than the non-faller group (p < 0.001). A stepwise logistic regression analysis demonstrated that stepping-response score was independently associated with falling (odds ratio = 0.15; p < 0.001). The ROC curve had a moderate AUC (0.73) for stepping-response score (sensitivity 73.0 %; specificity 69.7 %). Conclusions: This study indicates that the stepping-response score calculated from measurements obtained using the new step-tracking device can identify elderly individuals who are at a risk of falling.

KW - Elderly

KW - Falls

KW - Laser range finder

KW - Step-tracking device

KW - Stepping performance

UR - http://www.scopus.com/inward/record.url?scp=84886682677&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84886682677&partnerID=8YFLogxK

U2 - 10.1007/s40520-013-0042-9

DO - 10.1007/s40520-013-0042-9

M3 - Article

VL - 25

SP - 311

EP - 316

JO - Aging clinical and experimental research

JF - Aging clinical and experimental research

SN - 1594-0667

IS - 3

ER -