Abstract

In this study, fatigue tests were performed for NiCo alloy which is commonly used in probe tips of test machines of semiconductors. The smooth specimens were fabricated by MEMS process including electro-plating process on a single-side polished 6 inches (100) silicon wafer. The NiCo thin film consists of about 66.2 % Ni and 33.8 % Co. The specimen is 2000 μm long, 9 μm thick and 100 μm wide. The tests were performed using a novel test procedure, a structure of the specimen is easy to manipulate, align and grip a thin-film and a test machine proposed by the authors. The closed-loop feedback control of the magnetic-electric actuator allowed load-controlled and high cycle fatigue tests with 5 Hz frequency, in ambient environment and with a stress ratio of R = 0.1. The fatigue strength coefficient and exponent were 1324 MPa and -0.0558, respectively. In a fatigue test of thin film, it is difficult to perform the fatigue test at R = -1. However, the result of the fatigue test at R = -1 should be required when fatigue life prediction is performed under variable loading. Therefore, in this study, the modified Goodman method, Gerber method and Soderberg method were considered to investigate which method is most reasonable when mean stress is considered.

Original languageEnglish
Pages (from-to)187-191
Number of pages5
JournalMaterialwissenschaft und Werkstofftechnik
Volume40
Issue number3
DOIs
Publication statusPublished - 2009 Mar 1
Externally publishedYes

Fingerprint

fatigue tests
Fatigue of materials
Thin films
probes
thin films
stress ratio
Electric actuators
Magnetic actuators
fatigue life
feedback control
plating
microelectromechanical systems
Silicon wafers
Plating
actuators
Feedback control
MEMS
exponents
wafers
cycles

Keywords

  • High cycle fatigue test
  • MEMS
  • NiCo alloy
  • Probe
  • Thin film

ASJC Scopus subject areas

  • Materials Science(all)
  • Condensed Matter Physics
  • Mechanics of Materials
  • Mechanical Engineering

Cite this

A study on the fatigue behaviour of electro-plated NiCo thin film for probe tip applications. / Park, J. H.; Chun, Y. B.; Kim, Yun Jae; Huh, Y. H.; Lee, H. J.

In: Materialwissenschaft und Werkstofftechnik, Vol. 40, No. 3, 01.03.2009, p. 187-191.

Research output: Contribution to journalArticle

@article{f9a42d0396ee466188f682bed907dc5f,
title = "A study on the fatigue behaviour of electro-plated NiCo thin film for probe tip applications",
abstract = "In this study, fatigue tests were performed for NiCo alloy which is commonly used in probe tips of test machines of semiconductors. The smooth specimens were fabricated by MEMS process including electro-plating process on a single-side polished 6 inches (100) silicon wafer. The NiCo thin film consists of about 66.2 {\%} Ni and 33.8 {\%} Co. The specimen is 2000 μm long, 9 μm thick and 100 μm wide. The tests were performed using a novel test procedure, a structure of the specimen is easy to manipulate, align and grip a thin-film and a test machine proposed by the authors. The closed-loop feedback control of the magnetic-electric actuator allowed load-controlled and high cycle fatigue tests with 5 Hz frequency, in ambient environment and with a stress ratio of R = 0.1. The fatigue strength coefficient and exponent were 1324 MPa and -0.0558, respectively. In a fatigue test of thin film, it is difficult to perform the fatigue test at R = -1. However, the result of the fatigue test at R = -1 should be required when fatigue life prediction is performed under variable loading. Therefore, in this study, the modified Goodman method, Gerber method and Soderberg method were considered to investigate which method is most reasonable when mean stress is considered.",
keywords = "High cycle fatigue test, MEMS, NiCo alloy, Probe, Thin film",
author = "Park, {J. H.} and Chun, {Y. B.} and Kim, {Yun Jae} and Huh, {Y. H.} and Lee, {H. J.}",
year = "2009",
month = "3",
day = "1",
doi = "10.1002/mawe.200900425",
language = "English",
volume = "40",
pages = "187--191",
journal = "Materialwissenschaft und Werkstofftechnik",
issn = "0933-5137",
publisher = "Wiley-VCH Verlag",
number = "3",

}

TY - JOUR

T1 - A study on the fatigue behaviour of electro-plated NiCo thin film for probe tip applications

AU - Park, J. H.

AU - Chun, Y. B.

AU - Kim, Yun Jae

AU - Huh, Y. H.

AU - Lee, H. J.

PY - 2009/3/1

Y1 - 2009/3/1

N2 - In this study, fatigue tests were performed for NiCo alloy which is commonly used in probe tips of test machines of semiconductors. The smooth specimens were fabricated by MEMS process including electro-plating process on a single-side polished 6 inches (100) silicon wafer. The NiCo thin film consists of about 66.2 % Ni and 33.8 % Co. The specimen is 2000 μm long, 9 μm thick and 100 μm wide. The tests were performed using a novel test procedure, a structure of the specimen is easy to manipulate, align and grip a thin-film and a test machine proposed by the authors. The closed-loop feedback control of the magnetic-electric actuator allowed load-controlled and high cycle fatigue tests with 5 Hz frequency, in ambient environment and with a stress ratio of R = 0.1. The fatigue strength coefficient and exponent were 1324 MPa and -0.0558, respectively. In a fatigue test of thin film, it is difficult to perform the fatigue test at R = -1. However, the result of the fatigue test at R = -1 should be required when fatigue life prediction is performed under variable loading. Therefore, in this study, the modified Goodman method, Gerber method and Soderberg method were considered to investigate which method is most reasonable when mean stress is considered.

AB - In this study, fatigue tests were performed for NiCo alloy which is commonly used in probe tips of test machines of semiconductors. The smooth specimens were fabricated by MEMS process including electro-plating process on a single-side polished 6 inches (100) silicon wafer. The NiCo thin film consists of about 66.2 % Ni and 33.8 % Co. The specimen is 2000 μm long, 9 μm thick and 100 μm wide. The tests were performed using a novel test procedure, a structure of the specimen is easy to manipulate, align and grip a thin-film and a test machine proposed by the authors. The closed-loop feedback control of the magnetic-electric actuator allowed load-controlled and high cycle fatigue tests with 5 Hz frequency, in ambient environment and with a stress ratio of R = 0.1. The fatigue strength coefficient and exponent were 1324 MPa and -0.0558, respectively. In a fatigue test of thin film, it is difficult to perform the fatigue test at R = -1. However, the result of the fatigue test at R = -1 should be required when fatigue life prediction is performed under variable loading. Therefore, in this study, the modified Goodman method, Gerber method and Soderberg method were considered to investigate which method is most reasonable when mean stress is considered.

KW - High cycle fatigue test

KW - MEMS

KW - NiCo alloy

KW - Probe

KW - Thin film

UR - http://www.scopus.com/inward/record.url?scp=67649194712&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=67649194712&partnerID=8YFLogxK

U2 - 10.1002/mawe.200900425

DO - 10.1002/mawe.200900425

M3 - Article

VL - 40

SP - 187

EP - 191

JO - Materialwissenschaft und Werkstofftechnik

JF - Materialwissenschaft und Werkstofftechnik

SN - 0933-5137

IS - 3

ER -