Accurate frequency measurement of the ν3 band of methane from sub-Doppler resolution comb-referenced spectroscopy

M. Abe, S. Okubo, K. Iwakuni, H. Nakayama, H. Inaba, Hiroyuki Sasada

Research output: Chapter in Book/Report/Conference proceedingConference contribution

1 Citation (Scopus)

Abstract

We have determined 183 sub-Doppler resolution spectral frequencies of 12CH4 using a difference-frequency-generation source, an enhanced-cavity absorption cell, and an optical frequency comb from 86.7 to 93.1 THz with a typical uncertainty of 3 kHz.

Original languageEnglish
Title of host publicationPacific Rim Conference on Lasers and Electro-Optics, CLEO - Technical Digest
DOIs
Publication statusPublished - 2013
Event10th Conference on Lasers and Electro-Optics Pacific Rim, CLEO-PR 2013 - Kyoto, Japan
Duration: 2013 Jun 302013 Jul 4

Other

Other10th Conference on Lasers and Electro-Optics Pacific Rim, CLEO-PR 2013
CountryJapan
CityKyoto
Period13/6/3013/7/4

Fingerprint

Spectral resolution
Methane
frequency measurement
methane
Spectroscopy
spectroscopy
spectral resolution
cavities
cells
Uncertainty

ASJC Scopus subject areas

  • Condensed Matter Physics
  • Atomic and Molecular Physics, and Optics
  • Electronic, Optical and Magnetic Materials
  • Electrical and Electronic Engineering

Cite this

Abe, M., Okubo, S., Iwakuni, K., Nakayama, H., Inaba, H., & Sasada, H. (2013). Accurate frequency measurement of the ν3 band of methane from sub-Doppler resolution comb-referenced spectroscopy. In Pacific Rim Conference on Lasers and Electro-Optics, CLEO - Technical Digest [6600047] https://doi.org/10.1109/CLEOPR.2013.6600047

Accurate frequency measurement of the ν3 band of methane from sub-Doppler resolution comb-referenced spectroscopy. / Abe, M.; Okubo, S.; Iwakuni, K.; Nakayama, H.; Inaba, H.; Sasada, Hiroyuki.

Pacific Rim Conference on Lasers and Electro-Optics, CLEO - Technical Digest. 2013. 6600047.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abe, M, Okubo, S, Iwakuni, K, Nakayama, H, Inaba, H & Sasada, H 2013, Accurate frequency measurement of the ν3 band of methane from sub-Doppler resolution comb-referenced spectroscopy. in Pacific Rim Conference on Lasers and Electro-Optics, CLEO - Technical Digest., 6600047, 10th Conference on Lasers and Electro-Optics Pacific Rim, CLEO-PR 2013, Kyoto, Japan, 13/6/30. https://doi.org/10.1109/CLEOPR.2013.6600047
Abe M, Okubo S, Iwakuni K, Nakayama H, Inaba H, Sasada H. Accurate frequency measurement of the ν3 band of methane from sub-Doppler resolution comb-referenced spectroscopy. In Pacific Rim Conference on Lasers and Electro-Optics, CLEO - Technical Digest. 2013. 6600047 https://doi.org/10.1109/CLEOPR.2013.6600047
Abe, M. ; Okubo, S. ; Iwakuni, K. ; Nakayama, H. ; Inaba, H. ; Sasada, Hiroyuki. / Accurate frequency measurement of the ν3 band of methane from sub-Doppler resolution comb-referenced spectroscopy. Pacific Rim Conference on Lasers and Electro-Optics, CLEO - Technical Digest. 2013.
@inproceedings{04061dcf814241d199b866438b9248c8,
title = "Accurate frequency measurement of the ν3 band of methane from sub-Doppler resolution comb-referenced spectroscopy",
abstract = "We have determined 183 sub-Doppler resolution spectral frequencies of 12CH4 using a difference-frequency-generation source, an enhanced-cavity absorption cell, and an optical frequency comb from 86.7 to 93.1 THz with a typical uncertainty of 3 kHz.",
author = "M. Abe and S. Okubo and K. Iwakuni and H. Nakayama and H. Inaba and Hiroyuki Sasada",
year = "2013",
doi = "10.1109/CLEOPR.2013.6600047",
language = "English",
isbn = "9781467364751",
booktitle = "Pacific Rim Conference on Lasers and Electro-Optics, CLEO - Technical Digest",

}

TY - GEN

T1 - Accurate frequency measurement of the ν3 band of methane from sub-Doppler resolution comb-referenced spectroscopy

AU - Abe, M.

AU - Okubo, S.

AU - Iwakuni, K.

AU - Nakayama, H.

AU - Inaba, H.

AU - Sasada, Hiroyuki

PY - 2013

Y1 - 2013

N2 - We have determined 183 sub-Doppler resolution spectral frequencies of 12CH4 using a difference-frequency-generation source, an enhanced-cavity absorption cell, and an optical frequency comb from 86.7 to 93.1 THz with a typical uncertainty of 3 kHz.

AB - We have determined 183 sub-Doppler resolution spectral frequencies of 12CH4 using a difference-frequency-generation source, an enhanced-cavity absorption cell, and an optical frequency comb from 86.7 to 93.1 THz with a typical uncertainty of 3 kHz.

UR - http://www.scopus.com/inward/record.url?scp=84885461496&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84885461496&partnerID=8YFLogxK

U2 - 10.1109/CLEOPR.2013.6600047

DO - 10.1109/CLEOPR.2013.6600047

M3 - Conference contribution

SN - 9781467364751

BT - Pacific Rim Conference on Lasers and Electro-Optics, CLEO - Technical Digest

ER -