An active valve incorporated into a microchip using a high strain electroactive polymer

Yo Tanaka, Tomohiro Fujikawa, Yutaka Kazoe, Takehiko Kitamori

Research output: Contribution to journalArticle

18 Citations (Scopus)

Abstract

Recently, various kinds of microvalves have been developed in the field of micro total analysis systems. Most are pneumatic or piezo electric valves, which require significant space on a microchip and hence make the system complicated. This study reports the use of an electroactive polymer-based microvalve that occupies only a small space on a microchip. An electroactive polymer membrane sandwiched between soft electrode sheets was placed on a dome-shaped diaphragm. The polymer actuator was installed in a glass microchip and the valve function was demonstrated. First, the displacement of the diaphragm was measured without fluid, and sufficient displacement (over 50 μm) was obtained for valve closing. Second, flow in a linear microchannel was stopped and then restarted by the valve. The flow in the microchannel produced by the constant pressure from a microfluidic controller (1.0 kPa) was completely stopped by applying a 50 V/μm electric field. This valve functioned well at pressures up to 4.0 kPa. The response time was about 0.7 s, similar to the time required for piezo electric actuator valves in channels of this size. This type of valve is very suitable for portable devices filed because of its compactness.

Original languageEnglish
Pages (from-to)163-169
Number of pages7
JournalSensors and Actuators, B: Chemical
Volume184
DOIs
Publication statusPublished - 2013 May 27

Fingerprint

electroactive polymers
Polymers
Diaphragms
Microchannels
Piezoelectric actuators
Domes
Microfluidics
Pneumatics
diaphragms
microchannels
Actuators
Electric fields
Membranes
Glass
Controllers
Electrodes
Fluids
piezoelectric actuators
pneumatics
systems analysis

Keywords

  • Dome shape structure
  • Electroactive polymer
  • Microfluidic device
  • Microvalve
  • Portable device

ASJC Scopus subject areas

  • Electronic, Optical and Magnetic Materials
  • Instrumentation
  • Condensed Matter Physics
  • Surfaces, Coatings and Films
  • Metals and Alloys
  • Materials Chemistry
  • Electrical and Electronic Engineering

Cite this

An active valve incorporated into a microchip using a high strain electroactive polymer. / Tanaka, Yo; Fujikawa, Tomohiro; Kazoe, Yutaka; Kitamori, Takehiko.

In: Sensors and Actuators, B: Chemical, Vol. 184, 27.05.2013, p. 163-169.

Research output: Contribution to journalArticle

Tanaka, Yo ; Fujikawa, Tomohiro ; Kazoe, Yutaka ; Kitamori, Takehiko. / An active valve incorporated into a microchip using a high strain electroactive polymer. In: Sensors and Actuators, B: Chemical. 2013 ; Vol. 184. pp. 163-169.
@article{5ef3c73f06594355b877da4609f1f8d1,
title = "An active valve incorporated into a microchip using a high strain electroactive polymer",
abstract = "Recently, various kinds of microvalves have been developed in the field of micro total analysis systems. Most are pneumatic or piezo electric valves, which require significant space on a microchip and hence make the system complicated. This study reports the use of an electroactive polymer-based microvalve that occupies only a small space on a microchip. An electroactive polymer membrane sandwiched between soft electrode sheets was placed on a dome-shaped diaphragm. The polymer actuator was installed in a glass microchip and the valve function was demonstrated. First, the displacement of the diaphragm was measured without fluid, and sufficient displacement (over 50 μm) was obtained for valve closing. Second, flow in a linear microchannel was stopped and then restarted by the valve. The flow in the microchannel produced by the constant pressure from a microfluidic controller (1.0 kPa) was completely stopped by applying a 50 V/μm electric field. This valve functioned well at pressures up to 4.0 kPa. The response time was about 0.7 s, similar to the time required for piezo electric actuator valves in channels of this size. This type of valve is very suitable for portable devices filed because of its compactness.",
keywords = "Dome shape structure, Electroactive polymer, Microfluidic device, Microvalve, Portable device",
author = "Yo Tanaka and Tomohiro Fujikawa and Yutaka Kazoe and Takehiko Kitamori",
year = "2013",
month = "5",
day = "27",
doi = "10.1016/j.snb.2013.04.025",
language = "English",
volume = "184",
pages = "163--169",
journal = "Sensors and Actuators, B: Chemical",
issn = "0925-4005",
publisher = "Elsevier",

}

TY - JOUR

T1 - An active valve incorporated into a microchip using a high strain electroactive polymer

AU - Tanaka, Yo

AU - Fujikawa, Tomohiro

AU - Kazoe, Yutaka

AU - Kitamori, Takehiko

PY - 2013/5/27

Y1 - 2013/5/27

N2 - Recently, various kinds of microvalves have been developed in the field of micro total analysis systems. Most are pneumatic or piezo electric valves, which require significant space on a microchip and hence make the system complicated. This study reports the use of an electroactive polymer-based microvalve that occupies only a small space on a microchip. An electroactive polymer membrane sandwiched between soft electrode sheets was placed on a dome-shaped diaphragm. The polymer actuator was installed in a glass microchip and the valve function was demonstrated. First, the displacement of the diaphragm was measured without fluid, and sufficient displacement (over 50 μm) was obtained for valve closing. Second, flow in a linear microchannel was stopped and then restarted by the valve. The flow in the microchannel produced by the constant pressure from a microfluidic controller (1.0 kPa) was completely stopped by applying a 50 V/μm electric field. This valve functioned well at pressures up to 4.0 kPa. The response time was about 0.7 s, similar to the time required for piezo electric actuator valves in channels of this size. This type of valve is very suitable for portable devices filed because of its compactness.

AB - Recently, various kinds of microvalves have been developed in the field of micro total analysis systems. Most are pneumatic or piezo electric valves, which require significant space on a microchip and hence make the system complicated. This study reports the use of an electroactive polymer-based microvalve that occupies only a small space on a microchip. An electroactive polymer membrane sandwiched between soft electrode sheets was placed on a dome-shaped diaphragm. The polymer actuator was installed in a glass microchip and the valve function was demonstrated. First, the displacement of the diaphragm was measured without fluid, and sufficient displacement (over 50 μm) was obtained for valve closing. Second, flow in a linear microchannel was stopped and then restarted by the valve. The flow in the microchannel produced by the constant pressure from a microfluidic controller (1.0 kPa) was completely stopped by applying a 50 V/μm electric field. This valve functioned well at pressures up to 4.0 kPa. The response time was about 0.7 s, similar to the time required for piezo electric actuator valves in channels of this size. This type of valve is very suitable for portable devices filed because of its compactness.

KW - Dome shape structure

KW - Electroactive polymer

KW - Microfluidic device

KW - Microvalve

KW - Portable device

UR - http://www.scopus.com/inward/record.url?scp=84877996880&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84877996880&partnerID=8YFLogxK

U2 - 10.1016/j.snb.2013.04.025

DO - 10.1016/j.snb.2013.04.025

M3 - Article

AN - SCOPUS:84877996880

VL - 184

SP - 163

EP - 169

JO - Sensors and Actuators, B: Chemical

JF - Sensors and Actuators, B: Chemical

SN - 0925-4005

ER -