An alternative limb lead system for electrocardiographs in emergency patients

Kiyotsugu Takuma, Shingo Hori, Junichi Sasaki, Yotaro Shinozawa, Tsutomu Yoshikawa, Shunnosuke Handa, Muneyuki Horikawa, Naoki Aikawa

Research output: Contribution to journalArticle

14 Citations (Scopus)

Abstract

It is occasionally difficult to record the standard 12-lead electrocardiograph (ECG) in emergency patients. The aim of this study was to evaluate the influence on electrocardiographic wave form recordings of moving the location of electrodes from the standard limb lead position to the trunk. The participants were 10 normal subjects and 20 patients with heart disease. In the new lead system, the limb electrodes were placed on the anterior acromial region and the anterior superior iliac spine using adhesive electrodes. Conventional 12-lead ECGs were recorded by the standard and the new lead system simultaneously in the supine position. Wave form analysis was done by an automatic analysis program. Motion artifacts in the recordings were less in the new lead system. The R wave amplitude of the new lead system increased in leads II, III and aVF, and decreased in leads I and aVL. However, the amplitudes of each wave obtained by standard electrocardiography and the new lead system correlated well (y = 1.008x + 2.038, r = 0.99, n = 2,880). In 99.6% of all wave forms, the differences in amplitudes were within 5% of the values of standard recordings. The average of differences in the ST-segment was 2.6 ± 11.4 μV. The frontal plane QRS axis obtained by the new lead system showed a vertical shift of 7.8 ± 8.5 degrees (y = 0.94911x + 10.346, r = 0.98, n = 30). The recording errors produced by the new lead system were within the permissible range of variation. The new lead system is a reasonable alternative for recording ECGs if application of the standard lead is difficult in an emergency.

Original languageEnglish
Pages (from-to)514-517
Number of pages4
JournalAmerican Journal of Emergency Medicine
Volume13
Issue number5
DOIs
Publication statusPublished - 1995

Fingerprint

Electrocardiography
Emergencies
Extremities
Electrodes
Lead
Supine Position
Adhesives
Artifacts
Heart Diseases
Spine

Keywords

  • ECG
  • emergency
  • lead system
  • prehospital care

ASJC Scopus subject areas

  • Emergency Medicine

Cite this

An alternative limb lead system for electrocardiographs in emergency patients. / Takuma, Kiyotsugu; Hori, Shingo; Sasaki, Junichi; Shinozawa, Yotaro; Yoshikawa, Tsutomu; Handa, Shunnosuke; Horikawa, Muneyuki; Aikawa, Naoki.

In: American Journal of Emergency Medicine, Vol. 13, No. 5, 1995, p. 514-517.

Research output: Contribution to journalArticle

Takuma, K, Hori, S, Sasaki, J, Shinozawa, Y, Yoshikawa, T, Handa, S, Horikawa, M & Aikawa, N 1995, 'An alternative limb lead system for electrocardiographs in emergency patients', American Journal of Emergency Medicine, vol. 13, no. 5, pp. 514-517. https://doi.org/10.1016/0735-6757(95)90160-4
Takuma, Kiyotsugu ; Hori, Shingo ; Sasaki, Junichi ; Shinozawa, Yotaro ; Yoshikawa, Tsutomu ; Handa, Shunnosuke ; Horikawa, Muneyuki ; Aikawa, Naoki. / An alternative limb lead system for electrocardiographs in emergency patients. In: American Journal of Emergency Medicine. 1995 ; Vol. 13, No. 5. pp. 514-517.
@article{70110e49579d4d279470fb7ac4aa3503,
title = "An alternative limb lead system for electrocardiographs in emergency patients",
abstract = "It is occasionally difficult to record the standard 12-lead electrocardiograph (ECG) in emergency patients. The aim of this study was to evaluate the influence on electrocardiographic wave form recordings of moving the location of electrodes from the standard limb lead position to the trunk. The participants were 10 normal subjects and 20 patients with heart disease. In the new lead system, the limb electrodes were placed on the anterior acromial region and the anterior superior iliac spine using adhesive electrodes. Conventional 12-lead ECGs were recorded by the standard and the new lead system simultaneously in the supine position. Wave form analysis was done by an automatic analysis program. Motion artifacts in the recordings were less in the new lead system. The R wave amplitude of the new lead system increased in leads II, III and aVF, and decreased in leads I and aVL. However, the amplitudes of each wave obtained by standard electrocardiography and the new lead system correlated well (y = 1.008x + 2.038, r = 0.99, n = 2,880). In 99.6{\%} of all wave forms, the differences in amplitudes were within 5{\%} of the values of standard recordings. The average of differences in the ST-segment was 2.6 ± 11.4 μV. The frontal plane QRS axis obtained by the new lead system showed a vertical shift of 7.8 ± 8.5 degrees (y = 0.94911x + 10.346, r = 0.98, n = 30). The recording errors produced by the new lead system were within the permissible range of variation. The new lead system is a reasonable alternative for recording ECGs if application of the standard lead is difficult in an emergency.",
keywords = "ECG, emergency, lead system, prehospital care",
author = "Kiyotsugu Takuma and Shingo Hori and Junichi Sasaki and Yotaro Shinozawa and Tsutomu Yoshikawa and Shunnosuke Handa and Muneyuki Horikawa and Naoki Aikawa",
year = "1995",
doi = "10.1016/0735-6757(95)90160-4",
language = "English",
volume = "13",
pages = "514--517",
journal = "The American journal of emergency medicine",
issn = "0735-6757",
publisher = "W.B. Saunders Ltd",
number = "5",

}

TY - JOUR

T1 - An alternative limb lead system for electrocardiographs in emergency patients

AU - Takuma, Kiyotsugu

AU - Hori, Shingo

AU - Sasaki, Junichi

AU - Shinozawa, Yotaro

AU - Yoshikawa, Tsutomu

AU - Handa, Shunnosuke

AU - Horikawa, Muneyuki

AU - Aikawa, Naoki

PY - 1995

Y1 - 1995

N2 - It is occasionally difficult to record the standard 12-lead electrocardiograph (ECG) in emergency patients. The aim of this study was to evaluate the influence on electrocardiographic wave form recordings of moving the location of electrodes from the standard limb lead position to the trunk. The participants were 10 normal subjects and 20 patients with heart disease. In the new lead system, the limb electrodes were placed on the anterior acromial region and the anterior superior iliac spine using adhesive electrodes. Conventional 12-lead ECGs were recorded by the standard and the new lead system simultaneously in the supine position. Wave form analysis was done by an automatic analysis program. Motion artifacts in the recordings were less in the new lead system. The R wave amplitude of the new lead system increased in leads II, III and aVF, and decreased in leads I and aVL. However, the amplitudes of each wave obtained by standard electrocardiography and the new lead system correlated well (y = 1.008x + 2.038, r = 0.99, n = 2,880). In 99.6% of all wave forms, the differences in amplitudes were within 5% of the values of standard recordings. The average of differences in the ST-segment was 2.6 ± 11.4 μV. The frontal plane QRS axis obtained by the new lead system showed a vertical shift of 7.8 ± 8.5 degrees (y = 0.94911x + 10.346, r = 0.98, n = 30). The recording errors produced by the new lead system were within the permissible range of variation. The new lead system is a reasonable alternative for recording ECGs if application of the standard lead is difficult in an emergency.

AB - It is occasionally difficult to record the standard 12-lead electrocardiograph (ECG) in emergency patients. The aim of this study was to evaluate the influence on electrocardiographic wave form recordings of moving the location of electrodes from the standard limb lead position to the trunk. The participants were 10 normal subjects and 20 patients with heart disease. In the new lead system, the limb electrodes were placed on the anterior acromial region and the anterior superior iliac spine using adhesive electrodes. Conventional 12-lead ECGs were recorded by the standard and the new lead system simultaneously in the supine position. Wave form analysis was done by an automatic analysis program. Motion artifacts in the recordings were less in the new lead system. The R wave amplitude of the new lead system increased in leads II, III and aVF, and decreased in leads I and aVL. However, the amplitudes of each wave obtained by standard electrocardiography and the new lead system correlated well (y = 1.008x + 2.038, r = 0.99, n = 2,880). In 99.6% of all wave forms, the differences in amplitudes were within 5% of the values of standard recordings. The average of differences in the ST-segment was 2.6 ± 11.4 μV. The frontal plane QRS axis obtained by the new lead system showed a vertical shift of 7.8 ± 8.5 degrees (y = 0.94911x + 10.346, r = 0.98, n = 30). The recording errors produced by the new lead system were within the permissible range of variation. The new lead system is a reasonable alternative for recording ECGs if application of the standard lead is difficult in an emergency.

KW - ECG

KW - emergency

KW - lead system

KW - prehospital care

UR - http://www.scopus.com/inward/record.url?scp=0029130320&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0029130320&partnerID=8YFLogxK

U2 - 10.1016/0735-6757(95)90160-4

DO - 10.1016/0735-6757(95)90160-4

M3 - Article

VL - 13

SP - 514

EP - 517

JO - The American journal of emergency medicine

JF - The American journal of emergency medicine

SN - 0735-6757

IS - 5

ER -