An intravoxel incoherent motion diffusion-weighted imaging study of prostate cancer

Hiroshi Shinmoto, Chiharu Tamura, Shigeyoshi Soga, Eisuke Shiomi, Nobuyuki Yoshihara, Tatsumi Kaji, Robert V. Mulkern

Research output: Contribution to journalArticle

67 Citations (Scopus)

Abstract

OBJECTIVE. The purpose of this study is to investigate whether the intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) parameters are different between prostate cancer, benign prostatic hyperplasia (BPH), and healthy peripheral zone (PZ). MATERIALS AND METHODS. Detailed diffusion measurements of 26 patients with histologically proven prostate cancer have been made in this retrospective study. Trace IVIM DWI was performed using 10 b values (0, 10, 20, 30, 50, 80, 100, 200, 400, and 1000 s/ mm 2). Biexponential fits were applied to diffusion decay curves to calculate molecular diffusion coefficient, perfusion-related diffusion coefficient, and perfusion fraction on the basis of the IVIM model. Decay curves were also fit with monoexponential decay functions, and a statistical comparison between mono- and biexponential fits was performed. Paired t tests were performed to evaluate the statistical significance of the parameters of IVIM DWI and apparent diffusion coefficient (ADC) between prostate cancer, BPH, and PZ. RESULTS. The chi-square values of biexponential fits were smaller than those from monoexponential fits in all cases. Biexponential functions provided statistically improved fits over monoexponential functions in 81% of cases. The ADC, molecular diffusion coefficient, and perfusion fraction in prostate cancer were significantly lower than those found in the PZ; however, perfusion fractions in prostate cancer and BPH were not significantly different. There were no significant differences in the prostate cancer, BPH, and PZ for the perfusionrelated diffusion coefficient, which had large SDs. CONCLUSION. IVIM DWI parameters are significantly different between prostate cancer and PZ. IVIM DWI may offer additional information for tissue characterization in the prostate gland.

Original languageEnglish
JournalAmerican Journal of Roentgenology
Volume199
Issue number4
DOIs
Publication statusPublished - 2012 Oct
Externally publishedYes

Fingerprint

Prostatic Neoplasms
Prostatic Hyperplasia
Perfusion
Prostate
Retrospective Studies

Keywords

  • Biexponential fitting
  • Diffusion
  • Intravoxel incoherent motion
  • MRI
  • Prostate cancer

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Shinmoto, H., Tamura, C., Soga, S., Shiomi, E., Yoshihara, N., Kaji, T., & Mulkern, R. V. (2012). An intravoxel incoherent motion diffusion-weighted imaging study of prostate cancer. American Journal of Roentgenology, 199(4). https://doi.org/10.2214/AJR.11.8347

An intravoxel incoherent motion diffusion-weighted imaging study of prostate cancer. / Shinmoto, Hiroshi; Tamura, Chiharu; Soga, Shigeyoshi; Shiomi, Eisuke; Yoshihara, Nobuyuki; Kaji, Tatsumi; Mulkern, Robert V.

In: American Journal of Roentgenology, Vol. 199, No. 4, 10.2012.

Research output: Contribution to journalArticle

Shinmoto, H, Tamura, C, Soga, S, Shiomi, E, Yoshihara, N, Kaji, T & Mulkern, RV 2012, 'An intravoxel incoherent motion diffusion-weighted imaging study of prostate cancer', American Journal of Roentgenology, vol. 199, no. 4. https://doi.org/10.2214/AJR.11.8347
Shinmoto, Hiroshi ; Tamura, Chiharu ; Soga, Shigeyoshi ; Shiomi, Eisuke ; Yoshihara, Nobuyuki ; Kaji, Tatsumi ; Mulkern, Robert V. / An intravoxel incoherent motion diffusion-weighted imaging study of prostate cancer. In: American Journal of Roentgenology. 2012 ; Vol. 199, No. 4.
@article{b5fdb65ebea74d4bb7393ab13737a68b,
title = "An intravoxel incoherent motion diffusion-weighted imaging study of prostate cancer",
abstract = "OBJECTIVE. The purpose of this study is to investigate whether the intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) parameters are different between prostate cancer, benign prostatic hyperplasia (BPH), and healthy peripheral zone (PZ). MATERIALS AND METHODS. Detailed diffusion measurements of 26 patients with histologically proven prostate cancer have been made in this retrospective study. Trace IVIM DWI was performed using 10 b values (0, 10, 20, 30, 50, 80, 100, 200, 400, and 1000 s/ mm 2). Biexponential fits were applied to diffusion decay curves to calculate molecular diffusion coefficient, perfusion-related diffusion coefficient, and perfusion fraction on the basis of the IVIM model. Decay curves were also fit with monoexponential decay functions, and a statistical comparison between mono- and biexponential fits was performed. Paired t tests were performed to evaluate the statistical significance of the parameters of IVIM DWI and apparent diffusion coefficient (ADC) between prostate cancer, BPH, and PZ. RESULTS. The chi-square values of biexponential fits were smaller than those from monoexponential fits in all cases. Biexponential functions provided statistically improved fits over monoexponential functions in 81{\%} of cases. The ADC, molecular diffusion coefficient, and perfusion fraction in prostate cancer were significantly lower than those found in the PZ; however, perfusion fractions in prostate cancer and BPH were not significantly different. There were no significant differences in the prostate cancer, BPH, and PZ for the perfusionrelated diffusion coefficient, which had large SDs. CONCLUSION. IVIM DWI parameters are significantly different between prostate cancer and PZ. IVIM DWI may offer additional information for tissue characterization in the prostate gland.",
keywords = "Biexponential fitting, Diffusion, Intravoxel incoherent motion, MRI, Prostate cancer",
author = "Hiroshi Shinmoto and Chiharu Tamura and Shigeyoshi Soga and Eisuke Shiomi and Nobuyuki Yoshihara and Tatsumi Kaji and Mulkern, {Robert V.}",
year = "2012",
month = "10",
doi = "10.2214/AJR.11.8347",
language = "English",
volume = "199",
journal = "American Journal of Roentgenology",
issn = "0361-803X",
publisher = "American Roentgen Ray Society",
number = "4",

}

TY - JOUR

T1 - An intravoxel incoherent motion diffusion-weighted imaging study of prostate cancer

AU - Shinmoto, Hiroshi

AU - Tamura, Chiharu

AU - Soga, Shigeyoshi

AU - Shiomi, Eisuke

AU - Yoshihara, Nobuyuki

AU - Kaji, Tatsumi

AU - Mulkern, Robert V.

PY - 2012/10

Y1 - 2012/10

N2 - OBJECTIVE. The purpose of this study is to investigate whether the intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) parameters are different between prostate cancer, benign prostatic hyperplasia (BPH), and healthy peripheral zone (PZ). MATERIALS AND METHODS. Detailed diffusion measurements of 26 patients with histologically proven prostate cancer have been made in this retrospective study. Trace IVIM DWI was performed using 10 b values (0, 10, 20, 30, 50, 80, 100, 200, 400, and 1000 s/ mm 2). Biexponential fits were applied to diffusion decay curves to calculate molecular diffusion coefficient, perfusion-related diffusion coefficient, and perfusion fraction on the basis of the IVIM model. Decay curves were also fit with monoexponential decay functions, and a statistical comparison between mono- and biexponential fits was performed. Paired t tests were performed to evaluate the statistical significance of the parameters of IVIM DWI and apparent diffusion coefficient (ADC) between prostate cancer, BPH, and PZ. RESULTS. The chi-square values of biexponential fits were smaller than those from monoexponential fits in all cases. Biexponential functions provided statistically improved fits over monoexponential functions in 81% of cases. The ADC, molecular diffusion coefficient, and perfusion fraction in prostate cancer were significantly lower than those found in the PZ; however, perfusion fractions in prostate cancer and BPH were not significantly different. There were no significant differences in the prostate cancer, BPH, and PZ for the perfusionrelated diffusion coefficient, which had large SDs. CONCLUSION. IVIM DWI parameters are significantly different between prostate cancer and PZ. IVIM DWI may offer additional information for tissue characterization in the prostate gland.

AB - OBJECTIVE. The purpose of this study is to investigate whether the intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) parameters are different between prostate cancer, benign prostatic hyperplasia (BPH), and healthy peripheral zone (PZ). MATERIALS AND METHODS. Detailed diffusion measurements of 26 patients with histologically proven prostate cancer have been made in this retrospective study. Trace IVIM DWI was performed using 10 b values (0, 10, 20, 30, 50, 80, 100, 200, 400, and 1000 s/ mm 2). Biexponential fits were applied to diffusion decay curves to calculate molecular diffusion coefficient, perfusion-related diffusion coefficient, and perfusion fraction on the basis of the IVIM model. Decay curves were also fit with monoexponential decay functions, and a statistical comparison between mono- and biexponential fits was performed. Paired t tests were performed to evaluate the statistical significance of the parameters of IVIM DWI and apparent diffusion coefficient (ADC) between prostate cancer, BPH, and PZ. RESULTS. The chi-square values of biexponential fits were smaller than those from monoexponential fits in all cases. Biexponential functions provided statistically improved fits over monoexponential functions in 81% of cases. The ADC, molecular diffusion coefficient, and perfusion fraction in prostate cancer were significantly lower than those found in the PZ; however, perfusion fractions in prostate cancer and BPH were not significantly different. There were no significant differences in the prostate cancer, BPH, and PZ for the perfusionrelated diffusion coefficient, which had large SDs. CONCLUSION. IVIM DWI parameters are significantly different between prostate cancer and PZ. IVIM DWI may offer additional information for tissue characterization in the prostate gland.

KW - Biexponential fitting

KW - Diffusion

KW - Intravoxel incoherent motion

KW - MRI

KW - Prostate cancer

UR - http://www.scopus.com/inward/record.url?scp=84866865468&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84866865468&partnerID=8YFLogxK

U2 - 10.2214/AJR.11.8347

DO - 10.2214/AJR.11.8347

M3 - Article

C2 - 22997399

AN - SCOPUS:84866865468

VL - 199

JO - American Journal of Roentgenology

JF - American Journal of Roentgenology

SN - 0361-803X

IS - 4

ER -