Analysis of biomechanical changes after removal of instrumentation in lumbar arthrodesis by finite element analysis

Ho Joong Kim, Heoung Jae Chun, Seong Hwan Moon, Kyoung Tak Kang, Hak Sun Kim, Jin Oh Park, Eun Su Moon, Joon Seok Sohn, Hwan Mo Lee

Research output: Contribution to journalArticle

21 Citations (Scopus)

Abstract

The purpose of this study is to investigate the change in biomechanical milieu following removal of pedicle screws in instrumented single level lumbar arthrodesis. Using a validated finite element (FE) model of the intact lumbar spine (L2-5), two scenarios of L3-4 lumbar fusion were simulated: posterolateral fusion (PLF) at L3-4 using pedicle screws (PLF with pedicle screws; WiP) and L3-4 lumbar posterolateral fusion state after removal of pedicle screws (PLF without pedicle screws; WoP). The WiP model had greater range of motion (ROM) at each adjacent segment than the WoP model. This phenomenon became pronounced at the proximal adjacent segment under flexion moment. Similarly, removal of pedicle screws (the WoP model) relieved the maximal von Mises stress at adjacent segments under 4 moments compared to the WiP model. This study demonstrated that removal of pedicle screws could decrease stiffness of fusion segments, which would reduce the disk stress of adjacent segments.

Original languageEnglish
Pages (from-to)703-709
Number of pages7
JournalMedical and Biological Engineering and Computing
Volume48
Issue number7
DOIs
Publication statusPublished - 2010 Jul 1
Externally publishedYes

Fingerprint

Fusion reactions
Finite element method
Stiffness

Keywords

  • Adjacent segment degeneration
  • Finite element method
  • Pedicle screws
  • Posterolateral fusion

ASJC Scopus subject areas

  • Biomedical Engineering
  • Computer Science Applications

Cite this

Analysis of biomechanical changes after removal of instrumentation in lumbar arthrodesis by finite element analysis. / Kim, Ho Joong; Chun, Heoung Jae; Moon, Seong Hwan; Kang, Kyoung Tak; Kim, Hak Sun; Park, Jin Oh; Moon, Eun Su; Sohn, Joon Seok; Lee, Hwan Mo.

In: Medical and Biological Engineering and Computing, Vol. 48, No. 7, 01.07.2010, p. 703-709.

Research output: Contribution to journalArticle

Kim, Ho Joong ; Chun, Heoung Jae ; Moon, Seong Hwan ; Kang, Kyoung Tak ; Kim, Hak Sun ; Park, Jin Oh ; Moon, Eun Su ; Sohn, Joon Seok ; Lee, Hwan Mo. / Analysis of biomechanical changes after removal of instrumentation in lumbar arthrodesis by finite element analysis. In: Medical and Biological Engineering and Computing. 2010 ; Vol. 48, No. 7. pp. 703-709.
@article{a7602e9e4cf04d18a38b5d73ce7ab9ce,
title = "Analysis of biomechanical changes after removal of instrumentation in lumbar arthrodesis by finite element analysis",
abstract = "The purpose of this study is to investigate the change in biomechanical milieu following removal of pedicle screws in instrumented single level lumbar arthrodesis. Using a validated finite element (FE) model of the intact lumbar spine (L2-5), two scenarios of L3-4 lumbar fusion were simulated: posterolateral fusion (PLF) at L3-4 using pedicle screws (PLF with pedicle screws; WiP) and L3-4 lumbar posterolateral fusion state after removal of pedicle screws (PLF without pedicle screws; WoP). The WiP model had greater range of motion (ROM) at each adjacent segment than the WoP model. This phenomenon became pronounced at the proximal adjacent segment under flexion moment. Similarly, removal of pedicle screws (the WoP model) relieved the maximal von Mises stress at adjacent segments under 4 moments compared to the WiP model. This study demonstrated that removal of pedicle screws could decrease stiffness of fusion segments, which would reduce the disk stress of adjacent segments.",
keywords = "Adjacent segment degeneration, Finite element method, Pedicle screws, Posterolateral fusion",
author = "Kim, {Ho Joong} and Chun, {Heoung Jae} and Moon, {Seong Hwan} and Kang, {Kyoung Tak} and Kim, {Hak Sun} and Park, {Jin Oh} and Moon, {Eun Su} and Sohn, {Joon Seok} and Lee, {Hwan Mo}",
year = "2010",
month = "7",
day = "1",
doi = "10.1007/s11517-010-0621-2",
language = "English",
volume = "48",
pages = "703--709",
journal = "Medical and Biological Engineering and Computing",
issn = "0140-0118",
publisher = "Springer Verlag",
number = "7",

}

TY - JOUR

T1 - Analysis of biomechanical changes after removal of instrumentation in lumbar arthrodesis by finite element analysis

AU - Kim, Ho Joong

AU - Chun, Heoung Jae

AU - Moon, Seong Hwan

AU - Kang, Kyoung Tak

AU - Kim, Hak Sun

AU - Park, Jin Oh

AU - Moon, Eun Su

AU - Sohn, Joon Seok

AU - Lee, Hwan Mo

PY - 2010/7/1

Y1 - 2010/7/1

N2 - The purpose of this study is to investigate the change in biomechanical milieu following removal of pedicle screws in instrumented single level lumbar arthrodesis. Using a validated finite element (FE) model of the intact lumbar spine (L2-5), two scenarios of L3-4 lumbar fusion were simulated: posterolateral fusion (PLF) at L3-4 using pedicle screws (PLF with pedicle screws; WiP) and L3-4 lumbar posterolateral fusion state after removal of pedicle screws (PLF without pedicle screws; WoP). The WiP model had greater range of motion (ROM) at each adjacent segment than the WoP model. This phenomenon became pronounced at the proximal adjacent segment under flexion moment. Similarly, removal of pedicle screws (the WoP model) relieved the maximal von Mises stress at adjacent segments under 4 moments compared to the WiP model. This study demonstrated that removal of pedicle screws could decrease stiffness of fusion segments, which would reduce the disk stress of adjacent segments.

AB - The purpose of this study is to investigate the change in biomechanical milieu following removal of pedicle screws in instrumented single level lumbar arthrodesis. Using a validated finite element (FE) model of the intact lumbar spine (L2-5), two scenarios of L3-4 lumbar fusion were simulated: posterolateral fusion (PLF) at L3-4 using pedicle screws (PLF with pedicle screws; WiP) and L3-4 lumbar posterolateral fusion state after removal of pedicle screws (PLF without pedicle screws; WoP). The WiP model had greater range of motion (ROM) at each adjacent segment than the WoP model. This phenomenon became pronounced at the proximal adjacent segment under flexion moment. Similarly, removal of pedicle screws (the WoP model) relieved the maximal von Mises stress at adjacent segments under 4 moments compared to the WiP model. This study demonstrated that removal of pedicle screws could decrease stiffness of fusion segments, which would reduce the disk stress of adjacent segments.

KW - Adjacent segment degeneration

KW - Finite element method

KW - Pedicle screws

KW - Posterolateral fusion

UR - http://www.scopus.com/inward/record.url?scp=77954424628&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77954424628&partnerID=8YFLogxK

U2 - 10.1007/s11517-010-0621-2

DO - 10.1007/s11517-010-0621-2

M3 - Article

VL - 48

SP - 703

EP - 709

JO - Medical and Biological Engineering and Computing

JF - Medical and Biological Engineering and Computing

SN - 0140-0118

IS - 7

ER -