Cranioplasty using custom-made hydroxyapatite (HAP) ceramic implants is a common procedure to repair skull defects. However, commercially available titanium screws are only minimally stabilized due to characteristic brittleness. We developed the RIVET technique which involves fixing a bioabsorbable plate atop a HAP block using bioabsorbable screws extending beyond both layers, and evaluated fixation strength using the pull-out test and microtomography. Three experimental conditions were compared: a non-RIVET group, RIVET group, and dry skull control group. Pull-out strength significantly differed across groups (non-RIVET group, 1.33 ± 1.21 kgf; RIVET group, 4.46 ± 0.84 kgf; and control group, 6.99 ± 1.14 kgf, P < 0.01). Microtomography of the dry skull control group revealed thread grooves fitted to the screws. The non-RIVET and RIVET groups presented fewer thread grooves than the control group, and the screws did not fit perfectly to the HAP block. However, fixation in the RIVET group was more stable, as the rivet was firmly lodged into the implant. In conclusion, by melting and creating the rivet, pull-out strength can be increased and rigid stabilization of HAP can be obtained. This technique uses commercially available absorbable plate and screws, and thus can be used widely in clinical applications involving HAP blocks with different porosities and thicknesses.

Original languageEnglish
Pages (from-to)281-284
Number of pages4
JournalJournal of Cranio-Maxillofacial Surgery
Volume43
Issue number2
DOIs
Publication statusPublished - 2015 Mar 1

Fingerprint

Durapatite
Skull
Control Groups
Porosity
Ceramics
Titanium
Freezing

Keywords

  • Bioabsorbable fixation
  • Cranial defect
  • Cranioplasty
  • Hydroxyapatite
  • Physical strength
  • Skull defect

ASJC Scopus subject areas

  • Oral Surgery
  • Otorhinolaryngology
  • Surgery

Cite this

Assessment of the RIVET fixation system for cranioplasty using the pull-out technique. / Sakamoto, Yoshiaki; Minabe, Toshiharu; Kato, Tatsuya; Kishi, Kazuo.

In: Journal of Cranio-Maxillofacial Surgery, Vol. 43, No. 2, 01.03.2015, p. 281-284.

Research output: Contribution to journalArticle

@article{9aeaf9abf22f414eba9cf8a43d62c494,
title = "Assessment of the RIVET fixation system for cranioplasty using the pull-out technique",
abstract = "Cranioplasty using custom-made hydroxyapatite (HAP) ceramic implants is a common procedure to repair skull defects. However, commercially available titanium screws are only minimally stabilized due to characteristic brittleness. We developed the RIVET technique which involves fixing a bioabsorbable plate atop a HAP block using bioabsorbable screws extending beyond both layers, and evaluated fixation strength using the pull-out test and microtomography. Three experimental conditions were compared: a non-RIVET group, RIVET group, and dry skull control group. Pull-out strength significantly differed across groups (non-RIVET group, 1.33 ± 1.21 kgf; RIVET group, 4.46 ± 0.84 kgf; and control group, 6.99 ± 1.14 kgf, P < 0.01). Microtomography of the dry skull control group revealed thread grooves fitted to the screws. The non-RIVET and RIVET groups presented fewer thread grooves than the control group, and the screws did not fit perfectly to the HAP block. However, fixation in the RIVET group was more stable, as the rivet was firmly lodged into the implant. In conclusion, by melting and creating the rivet, pull-out strength can be increased and rigid stabilization of HAP can be obtained. This technique uses commercially available absorbable plate and screws, and thus can be used widely in clinical applications involving HAP blocks with different porosities and thicknesses.",
keywords = "Bioabsorbable fixation, Cranial defect, Cranioplasty, Hydroxyapatite, Physical strength, Skull defect",
author = "Yoshiaki Sakamoto and Toshiharu Minabe and Tatsuya Kato and Kazuo Kishi",
year = "2015",
month = "3",
day = "1",
doi = "10.1016/j.jcms.2014.12.001",
language = "English",
volume = "43",
pages = "281--284",
journal = "Journal of Cranio-Maxillofacial Surgery",
issn = "1010-5182",
publisher = "Churchill Livingstone",
number = "2",

}

TY - JOUR

T1 - Assessment of the RIVET fixation system for cranioplasty using the pull-out technique

AU - Sakamoto, Yoshiaki

AU - Minabe, Toshiharu

AU - Kato, Tatsuya

AU - Kishi, Kazuo

PY - 2015/3/1

Y1 - 2015/3/1

N2 - Cranioplasty using custom-made hydroxyapatite (HAP) ceramic implants is a common procedure to repair skull defects. However, commercially available titanium screws are only minimally stabilized due to characteristic brittleness. We developed the RIVET technique which involves fixing a bioabsorbable plate atop a HAP block using bioabsorbable screws extending beyond both layers, and evaluated fixation strength using the pull-out test and microtomography. Three experimental conditions were compared: a non-RIVET group, RIVET group, and dry skull control group. Pull-out strength significantly differed across groups (non-RIVET group, 1.33 ± 1.21 kgf; RIVET group, 4.46 ± 0.84 kgf; and control group, 6.99 ± 1.14 kgf, P < 0.01). Microtomography of the dry skull control group revealed thread grooves fitted to the screws. The non-RIVET and RIVET groups presented fewer thread grooves than the control group, and the screws did not fit perfectly to the HAP block. However, fixation in the RIVET group was more stable, as the rivet was firmly lodged into the implant. In conclusion, by melting and creating the rivet, pull-out strength can be increased and rigid stabilization of HAP can be obtained. This technique uses commercially available absorbable plate and screws, and thus can be used widely in clinical applications involving HAP blocks with different porosities and thicknesses.

AB - Cranioplasty using custom-made hydroxyapatite (HAP) ceramic implants is a common procedure to repair skull defects. However, commercially available titanium screws are only minimally stabilized due to characteristic brittleness. We developed the RIVET technique which involves fixing a bioabsorbable plate atop a HAP block using bioabsorbable screws extending beyond both layers, and evaluated fixation strength using the pull-out test and microtomography. Three experimental conditions were compared: a non-RIVET group, RIVET group, and dry skull control group. Pull-out strength significantly differed across groups (non-RIVET group, 1.33 ± 1.21 kgf; RIVET group, 4.46 ± 0.84 kgf; and control group, 6.99 ± 1.14 kgf, P < 0.01). Microtomography of the dry skull control group revealed thread grooves fitted to the screws. The non-RIVET and RIVET groups presented fewer thread grooves than the control group, and the screws did not fit perfectly to the HAP block. However, fixation in the RIVET group was more stable, as the rivet was firmly lodged into the implant. In conclusion, by melting and creating the rivet, pull-out strength can be increased and rigid stabilization of HAP can be obtained. This technique uses commercially available absorbable plate and screws, and thus can be used widely in clinical applications involving HAP blocks with different porosities and thicknesses.

KW - Bioabsorbable fixation

KW - Cranial defect

KW - Cranioplasty

KW - Hydroxyapatite

KW - Physical strength

KW - Skull defect

UR - http://www.scopus.com/inward/record.url?scp=84921354835&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84921354835&partnerID=8YFLogxK

U2 - 10.1016/j.jcms.2014.12.001

DO - 10.1016/j.jcms.2014.12.001

M3 - Article

C2 - 25555895

AN - SCOPUS:84921354835

VL - 43

SP - 281

EP - 284

JO - Journal of Cranio-Maxillofacial Surgery

JF - Journal of Cranio-Maxillofacial Surgery

SN - 1010-5182

IS - 2

ER -