A bone fixation system which uses a bioabsorbable material has been developed for the craniomaxillofacial area and is at present commercially available. We organized a study team to confirm the utility of and identify any problems with this bone fixation system. The team comprised six facilities and a study population of 57 cases undergoing craniomaxillofacial surgical procedures. The operative technique with the absorbable plates is complex compared with previous metallic bone fixation systems. The fixation strength is adequate and relatively problem free. However, the plates need to be combined with other fixing methods in areas subjected to heavy loading. The following advantages were noted when compared with metallic fixation systems: The plates do not require subsequent extraction because they are designed to be absorbed; therefore, areas where extraction would be difficult or even impossible become good indications. Allergic reactions to metal are eliminated. Problems caused by corrosion and motion of the implant resulting from leaving it in place for a long time do not occur. The plates cannot be seen on X-rays. Some disadvantages were found compared with metallic fixation systems, but we believe that the advantage of being absorbed in the living body is paramount and out weighs any disadvantages. As always, correct selection according to patient" indication leads to a high level of usefulness. In our opinion, this application will develop even further in the future.

Original languageEnglish
Pages (from-to)1079-1088
Number of pages10
JournalJapanese Journal of Plastic and Reconstructive Surgery
Volume47
Issue number10
Publication statusPublished - 2004 Oct

Fingerprint

Bone and Bones
Corrosion
Hypersensitivity
Metals
X-Rays
Population

ASJC Scopus subject areas

  • Surgery

Cite this

Kobayashi, M., Nakajima, T., Nakanishi, Y., Nakakita, N., Kamiishi, H., Hirano, A., & Yoshimura, Y. (2004). Clinical cases using absorbable plates in cranio-maxillo-facial surgery. Japanese Journal of Plastic and Reconstructive Surgery, 47(10), 1079-1088.

Clinical cases using absorbable plates in cranio-maxillo-facial surgery. / Kobayashi, Masahiro; Nakajima, Tatsuo; Nakanishi, Yuuji; Nakakita, Nobuaki; Kamiishi, Hiroshi; Hirano, Akiyoshi; Yoshimura, Yoko.

In: Japanese Journal of Plastic and Reconstructive Surgery, Vol. 47, No. 10, 10.2004, p. 1079-1088.

Research output: Contribution to journalArticle

Kobayashi, M, Nakajima, T, Nakanishi, Y, Nakakita, N, Kamiishi, H, Hirano, A & Yoshimura, Y 2004, 'Clinical cases using absorbable plates in cranio-maxillo-facial surgery', Japanese Journal of Plastic and Reconstructive Surgery, vol. 47, no. 10, pp. 1079-1088.
Kobayashi M, Nakajima T, Nakanishi Y, Nakakita N, Kamiishi H, Hirano A et al. Clinical cases using absorbable plates in cranio-maxillo-facial surgery. Japanese Journal of Plastic and Reconstructive Surgery. 2004 Oct;47(10):1079-1088.
Kobayashi, Masahiro ; Nakajima, Tatsuo ; Nakanishi, Yuuji ; Nakakita, Nobuaki ; Kamiishi, Hiroshi ; Hirano, Akiyoshi ; Yoshimura, Yoko. / Clinical cases using absorbable plates in cranio-maxillo-facial surgery. In: Japanese Journal of Plastic and Reconstructive Surgery. 2004 ; Vol. 47, No. 10. pp. 1079-1088.
@article{e551a3e25244444a80d1bee24f89bf76,
title = "Clinical cases using absorbable plates in cranio-maxillo-facial surgery",
abstract = "A bone fixation system which uses a bioabsorbable material has been developed for the craniomaxillofacial area and is at present commercially available. We organized a study team to confirm the utility of and identify any problems with this bone fixation system. The team comprised six facilities and a study population of 57 cases undergoing craniomaxillofacial surgical procedures. The operative technique with the absorbable plates is complex compared with previous metallic bone fixation systems. The fixation strength is adequate and relatively problem free. However, the plates need to be combined with other fixing methods in areas subjected to heavy loading. The following advantages were noted when compared with metallic fixation systems: The plates do not require subsequent extraction because they are designed to be absorbed; therefore, areas where extraction would be difficult or even impossible become good indications. Allergic reactions to metal are eliminated. Problems caused by corrosion and motion of the implant resulting from leaving it in place for a long time do not occur. The plates cannot be seen on X-rays. Some disadvantages were found compared with metallic fixation systems, but we believe that the advantage of being absorbed in the living body is paramount and out weighs any disadvantages. As always, correct selection according to patient{"} indication leads to a high level of usefulness. In our opinion, this application will develop even further in the future.",
author = "Masahiro Kobayashi and Tatsuo Nakajima and Yuuji Nakanishi and Nobuaki Nakakita and Hiroshi Kamiishi and Akiyoshi Hirano and Yoko Yoshimura",
year = "2004",
month = "10",
language = "English",
volume = "47",
pages = "1079--1088",
journal = "Japanese Journal of Plastic Surgery",
issn = "0021-5228",
publisher = "Kokuseido Publishing Co. Ltd",
number = "10",

}

TY - JOUR

T1 - Clinical cases using absorbable plates in cranio-maxillo-facial surgery

AU - Kobayashi, Masahiro

AU - Nakajima, Tatsuo

AU - Nakanishi, Yuuji

AU - Nakakita, Nobuaki

AU - Kamiishi, Hiroshi

AU - Hirano, Akiyoshi

AU - Yoshimura, Yoko

PY - 2004/10

Y1 - 2004/10

N2 - A bone fixation system which uses a bioabsorbable material has been developed for the craniomaxillofacial area and is at present commercially available. We organized a study team to confirm the utility of and identify any problems with this bone fixation system. The team comprised six facilities and a study population of 57 cases undergoing craniomaxillofacial surgical procedures. The operative technique with the absorbable plates is complex compared with previous metallic bone fixation systems. The fixation strength is adequate and relatively problem free. However, the plates need to be combined with other fixing methods in areas subjected to heavy loading. The following advantages were noted when compared with metallic fixation systems: The plates do not require subsequent extraction because they are designed to be absorbed; therefore, areas where extraction would be difficult or even impossible become good indications. Allergic reactions to metal are eliminated. Problems caused by corrosion and motion of the implant resulting from leaving it in place for a long time do not occur. The plates cannot be seen on X-rays. Some disadvantages were found compared with metallic fixation systems, but we believe that the advantage of being absorbed in the living body is paramount and out weighs any disadvantages. As always, correct selection according to patient" indication leads to a high level of usefulness. In our opinion, this application will develop even further in the future.

AB - A bone fixation system which uses a bioabsorbable material has been developed for the craniomaxillofacial area and is at present commercially available. We organized a study team to confirm the utility of and identify any problems with this bone fixation system. The team comprised six facilities and a study population of 57 cases undergoing craniomaxillofacial surgical procedures. The operative technique with the absorbable plates is complex compared with previous metallic bone fixation systems. The fixation strength is adequate and relatively problem free. However, the plates need to be combined with other fixing methods in areas subjected to heavy loading. The following advantages were noted when compared with metallic fixation systems: The plates do not require subsequent extraction because they are designed to be absorbed; therefore, areas where extraction would be difficult or even impossible become good indications. Allergic reactions to metal are eliminated. Problems caused by corrosion and motion of the implant resulting from leaving it in place for a long time do not occur. The plates cannot be seen on X-rays. Some disadvantages were found compared with metallic fixation systems, but we believe that the advantage of being absorbed in the living body is paramount and out weighs any disadvantages. As always, correct selection according to patient" indication leads to a high level of usefulness. In our opinion, this application will develop even further in the future.

UR - http://www.scopus.com/inward/record.url?scp=8144227328&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=8144227328&partnerID=8YFLogxK

M3 - Article

VL - 47

SP - 1079

EP - 1088

JO - Japanese Journal of Plastic Surgery

JF - Japanese Journal of Plastic Surgery

SN - 0021-5228

IS - 10

ER -