TY - JOUR
T1 - Combined femtosecond laser-assisted intracorneal ring segment implantation and corneal collagen cross-linking for correction of keratoconus
AU - Ibrahim, Osama
AU - Elmassry, Ahmed
AU - Said, Amr
AU - Abdalla, Moones
AU - El Hennawi, Hazem
AU - Osman, Ihab
N1 - Publisher Copyright:
© 2016 Ibrahim et al.
PY - 2016/3/22
Y1 - 2016/3/22
N2 - Purpose: To assess the safety, predictability, and effectiveness of Keraring intrastromal corneal ring segments (ICRS) insertion assisted by femtosecond laser and corneal collagen cross-linking (CXL) for keratoconus correction. Patients and methods: In this prospective, noncomparative, and interventional case series, 160 eyes of 100 adult keratoconus patients with poor best-corrected visual acuity (BCVA) (less than 0.7) and intolerance to contact lens wear were included. Patients underwent femtosecond laser-assisted placement of ICRS and CXL. All patients were examined for a complete ophthalmological test: uncorrected visual acuity (UCVA), BCVA, spherical equivalent, keratometry (K1-flat and K2-steep), pachymetry, and Scheimpflug imaging with the Pentacam at 1 week and at 1, 3, and 6 months postoperatively. Results: At 6 months, a significant difference was observed (P,0.001) in mean UCVA and BCVA from 0.92±0.677 and 0.42±0.600 logMAR preoperatively to 0.20±0.568 and 0.119±0.619 logMAR, respectively. Mean spherical equivalent refractions were significantly lower (P,0.001) at 6 months. Mean keratometry (K) also significantly reduced (P,0.001) from 50.93±5.53 D (K1-flat) and 55.37±5.76 D (K2-steep) to 47.32±4.61 and 51.08±5.38 D, respectively. In terms of pachymetry, no significant difference was observed preoperatively versus postoperatively (P=1.000). Conclusion: Keraring ICRS insertion assisted by femtosecond laser and corneal CXL provided significant improvement in visual acuity, spherical equivalent, and keratometry, which suggests that it may be effective, safe, and predictable for keratoconus correction.
AB - Purpose: To assess the safety, predictability, and effectiveness of Keraring intrastromal corneal ring segments (ICRS) insertion assisted by femtosecond laser and corneal collagen cross-linking (CXL) for keratoconus correction. Patients and methods: In this prospective, noncomparative, and interventional case series, 160 eyes of 100 adult keratoconus patients with poor best-corrected visual acuity (BCVA) (less than 0.7) and intolerance to contact lens wear were included. Patients underwent femtosecond laser-assisted placement of ICRS and CXL. All patients were examined for a complete ophthalmological test: uncorrected visual acuity (UCVA), BCVA, spherical equivalent, keratometry (K1-flat and K2-steep), pachymetry, and Scheimpflug imaging with the Pentacam at 1 week and at 1, 3, and 6 months postoperatively. Results: At 6 months, a significant difference was observed (P,0.001) in mean UCVA and BCVA from 0.92±0.677 and 0.42±0.600 logMAR preoperatively to 0.20±0.568 and 0.119±0.619 logMAR, respectively. Mean spherical equivalent refractions were significantly lower (P,0.001) at 6 months. Mean keratometry (K) also significantly reduced (P,0.001) from 50.93±5.53 D (K1-flat) and 55.37±5.76 D (K2-steep) to 47.32±4.61 and 51.08±5.38 D, respectively. In terms of pachymetry, no significant difference was observed preoperatively versus postoperatively (P=1.000). Conclusion: Keraring ICRS insertion assisted by femtosecond laser and corneal CXL provided significant improvement in visual acuity, spherical equivalent, and keratometry, which suggests that it may be effective, safe, and predictable for keratoconus correction.
KW - Irregular astigmatism
KW - Keratectesia
KW - Keratometry
KW - Pachymetry
KW - Pentacam
UR - http://www.scopus.com/inward/record.url?scp=84961753634&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84961753634&partnerID=8YFLogxK
U2 - 10.2147/OPTH.S97158
DO - 10.2147/OPTH.S97158
M3 - Article
AN - SCOPUS:84961753634
SN - 1177-5467
VL - 10
SP - 521
EP - 526
JO - Clinical Ophthalmology
JF - Clinical Ophthalmology
ER -