Compact 5 × 5 wavelength-selective cross connect using integrated 2-D MEMS mirror arrays

Keisuke Sorimoto, Hisato Uetsuka, Masao Tachikura, Hitoshi Kawashima, Masahiko Mori, Toshifumi Hasama, Hiroshi Ishikawa, Nazirul Afham Idris, Hiroyuki Tsuda

Research output: Chapter in Book/Report/Conference proceedingConference contribution

3 Citations (Scopus)

Abstract

We demonstrate a 5 × 5 wavelength selective cross-connect (WSXC) constituted by two newly developed MEMS devices with 5 × 46 micro-mirrors arranged two-dimensionally and Monk-Gillieson spectroscopic optics system, which is applicable to a 100-GHz channel grid. The introduction of the optics system leads to a WSXC with a small volume of 180 × 170 × 40 mm 3.

Original languageEnglish
Title of host publicationTechnical Digest of the 18th Microoptics Conference, MOC 2013
Publication statusPublished - 2013
Event2013 18th Microoptics Conference, MOC 2013 - Tokyo, Japan
Duration: 2013 Oct 272013 Oct 30

Other

Other2013 18th Microoptics Conference, MOC 2013
CountryJapan
CityTokyo
Period13/10/2713/10/30

Fingerprint

MEMS
Optics
Mirrors
Wavelength

ASJC Scopus subject areas

  • Electronic, Optical and Magnetic Materials

Cite this

Sorimoto, K., Uetsuka, H., Tachikura, M., Kawashima, H., Mori, M., Hasama, T., ... Tsuda, H. (2013). Compact 5 × 5 wavelength-selective cross connect using integrated 2-D MEMS mirror arrays. In Technical Digest of the 18th Microoptics Conference, MOC 2013 [6715075]

Compact 5 × 5 wavelength-selective cross connect using integrated 2-D MEMS mirror arrays. / Sorimoto, Keisuke; Uetsuka, Hisato; Tachikura, Masao; Kawashima, Hitoshi; Mori, Masahiko; Hasama, Toshifumi; Ishikawa, Hiroshi; Idris, Nazirul Afham; Tsuda, Hiroyuki.

Technical Digest of the 18th Microoptics Conference, MOC 2013. 2013. 6715075.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Sorimoto, K, Uetsuka, H, Tachikura, M, Kawashima, H, Mori, M, Hasama, T, Ishikawa, H, Idris, NA & Tsuda, H 2013, Compact 5 × 5 wavelength-selective cross connect using integrated 2-D MEMS mirror arrays. in Technical Digest of the 18th Microoptics Conference, MOC 2013., 6715075, 2013 18th Microoptics Conference, MOC 2013, Tokyo, Japan, 13/10/27.
Sorimoto K, Uetsuka H, Tachikura M, Kawashima H, Mori M, Hasama T et al. Compact 5 × 5 wavelength-selective cross connect using integrated 2-D MEMS mirror arrays. In Technical Digest of the 18th Microoptics Conference, MOC 2013. 2013. 6715075
Sorimoto, Keisuke ; Uetsuka, Hisato ; Tachikura, Masao ; Kawashima, Hitoshi ; Mori, Masahiko ; Hasama, Toshifumi ; Ishikawa, Hiroshi ; Idris, Nazirul Afham ; Tsuda, Hiroyuki. / Compact 5 × 5 wavelength-selective cross connect using integrated 2-D MEMS mirror arrays. Technical Digest of the 18th Microoptics Conference, MOC 2013. 2013.
@inproceedings{0ea00d00232d4fd6a1d5b9286f2b2a11,
title = "Compact 5 × 5 wavelength-selective cross connect using integrated 2-D MEMS mirror arrays",
abstract = "We demonstrate a 5 × 5 wavelength selective cross-connect (WSXC) constituted by two newly developed MEMS devices with 5 × 46 micro-mirrors arranged two-dimensionally and Monk-Gillieson spectroscopic optics system, which is applicable to a 100-GHz channel grid. The introduction of the optics system leads to a WSXC with a small volume of 180 × 170 × 40 mm 3.",
author = "Keisuke Sorimoto and Hisato Uetsuka and Masao Tachikura and Hitoshi Kawashima and Masahiko Mori and Toshifumi Hasama and Hiroshi Ishikawa and Idris, {Nazirul Afham} and Hiroyuki Tsuda",
year = "2013",
language = "English",
isbn = "9784863483453",
booktitle = "Technical Digest of the 18th Microoptics Conference, MOC 2013",

}

TY - GEN

T1 - Compact 5 × 5 wavelength-selective cross connect using integrated 2-D MEMS mirror arrays

AU - Sorimoto, Keisuke

AU - Uetsuka, Hisato

AU - Tachikura, Masao

AU - Kawashima, Hitoshi

AU - Mori, Masahiko

AU - Hasama, Toshifumi

AU - Ishikawa, Hiroshi

AU - Idris, Nazirul Afham

AU - Tsuda, Hiroyuki

PY - 2013

Y1 - 2013

N2 - We demonstrate a 5 × 5 wavelength selective cross-connect (WSXC) constituted by two newly developed MEMS devices with 5 × 46 micro-mirrors arranged two-dimensionally and Monk-Gillieson spectroscopic optics system, which is applicable to a 100-GHz channel grid. The introduction of the optics system leads to a WSXC with a small volume of 180 × 170 × 40 mm 3.

AB - We demonstrate a 5 × 5 wavelength selective cross-connect (WSXC) constituted by two newly developed MEMS devices with 5 × 46 micro-mirrors arranged two-dimensionally and Monk-Gillieson spectroscopic optics system, which is applicable to a 100-GHz channel grid. The introduction of the optics system leads to a WSXC with a small volume of 180 × 170 × 40 mm 3.

UR - http://www.scopus.com/inward/record.url?scp=84894129753&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84894129753&partnerID=8YFLogxK

M3 - Conference contribution

SN - 9784863483453

BT - Technical Digest of the 18th Microoptics Conference, MOC 2013

ER -