Comparison of serum 25-hydroxyvitamin D levels between radioimmunoassay and liquid chromatography-tandem mass spectrometry in infants and postpartum women

Kaori Hara, Kazushige Ikeda, Yuhei Koyama, Yasuhiro Wada, Tomonobu Hasegawa

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

Liquid chromatography-tandem mass spectrometry (LC-MS/MS) has become the gold standard for the measurement of serum 25-hydroxyvitamin D (25(OH)D) levels instead of the conventional method, radioimmunoassay (RIA). However, there was no study that compared RIA and LC-MS/MS for measuring serum 25(OH)D levels in infants and their mothers. The aim of this study was to assess the agreement of RIA and LC-MS/MS for measuring the serum levels in infants and postpartum women. This study enrolled 70 preterm infants, 113 term infants (134 samples), and 120 postpartum women. Serum concentration of 25(OH)D was measured by RIA and LC-MS/MS. We evaluated the correlation between RIA and LC-MS/MS. Also, we evaluated the bias between RIA and LC-MS/MS using Bland-Altman analysis. Sixty percent of preterm infants had serum 25(OH)D levels below the lower limit of quantification (LOQ) (4 ng/mL) and 90% of them were classified as vitamin D deficient. The serum 25(OH)D levels measured by RIA were significantly correlated with those measured by LC-MS/MS in all groups. According to the Bland-Altman plot, the serum 25(OH)D levels of infants measured by RIA had constant positive bias (mean±standard deviation [SD] [95% confidence interval, CI], preterm: +4.8± 2.4 ng/mL [4.2-5.4], term: +5.8±4.0 [5.1-6.5]) and proportional bias (preterm: r=0.44, p<0.01, term: r=0.50, p<0.01) compared with LC-MS/MS. The serum 25(OH)D levels of postpartum women measured by RIA had constant positive bias compared with LC-MS/MS, but no proportional bias was found. RIA demonstrated falsely high 25(OH)D levels when used for infants and postpartum women.

Original languageEnglish
Pages (from-to)1105-1111
Number of pages7
JournalJournal of Pediatric Endocrinology and Metabolism
Volume31
Issue number10
DOIs
Publication statusPublished - 2018 Oct 1

Fingerprint

Tandem Mass Spectrometry
Liquid Chromatography
Postpartum Period
Radioimmunoassay
Serum
Premature Infants
25-hydroxyvitamin D
Vitamin D
Mothers
Confidence Intervals

Keywords

  • 25-hydroxyvitamin D
  • infants
  • liquid chromatography tandem mass spectrometry
  • radioimmunoassay

ASJC Scopus subject areas

  • Pediatrics, Perinatology, and Child Health
  • Endocrinology, Diabetes and Metabolism
  • Endocrinology

Cite this

Comparison of serum 25-hydroxyvitamin D levels between radioimmunoassay and liquid chromatography-tandem mass spectrometry in infants and postpartum women. / Hara, Kaori; Ikeda, Kazushige; Koyama, Yuhei; Wada, Yasuhiro; Hasegawa, Tomonobu.

In: Journal of Pediatric Endocrinology and Metabolism, Vol. 31, No. 10, 01.10.2018, p. 1105-1111.

Research output: Contribution to journalArticle

@article{ebc5547b53644277b12bffe44f305a0b,
title = "Comparison of serum 25-hydroxyvitamin D levels between radioimmunoassay and liquid chromatography-tandem mass spectrometry in infants and postpartum women",
abstract = "Liquid chromatography-tandem mass spectrometry (LC-MS/MS) has become the gold standard for the measurement of serum 25-hydroxyvitamin D (25(OH)D) levels instead of the conventional method, radioimmunoassay (RIA). However, there was no study that compared RIA and LC-MS/MS for measuring serum 25(OH)D levels in infants and their mothers. The aim of this study was to assess the agreement of RIA and LC-MS/MS for measuring the serum levels in infants and postpartum women. This study enrolled 70 preterm infants, 113 term infants (134 samples), and 120 postpartum women. Serum concentration of 25(OH)D was measured by RIA and LC-MS/MS. We evaluated the correlation between RIA and LC-MS/MS. Also, we evaluated the bias between RIA and LC-MS/MS using Bland-Altman analysis. Sixty percent of preterm infants had serum 25(OH)D levels below the lower limit of quantification (LOQ) (4 ng/mL) and 90{\%} of them were classified as vitamin D deficient. The serum 25(OH)D levels measured by RIA were significantly correlated with those measured by LC-MS/MS in all groups. According to the Bland-Altman plot, the serum 25(OH)D levels of infants measured by RIA had constant positive bias (mean±standard deviation [SD] [95{\%} confidence interval, CI], preterm: +4.8± 2.4 ng/mL [4.2-5.4], term: +5.8±4.0 [5.1-6.5]) and proportional bias (preterm: r=0.44, p<0.01, term: r=0.50, p<0.01) compared with LC-MS/MS. The serum 25(OH)D levels of postpartum women measured by RIA had constant positive bias compared with LC-MS/MS, but no proportional bias was found. RIA demonstrated falsely high 25(OH)D levels when used for infants and postpartum women.",
keywords = "25-hydroxyvitamin D, infants, liquid chromatography tandem mass spectrometry, radioimmunoassay",
author = "Kaori Hara and Kazushige Ikeda and Yuhei Koyama and Yasuhiro Wada and Tomonobu Hasegawa",
year = "2018",
month = "10",
day = "1",
doi = "10.1515/jpem-2018-0275",
language = "English",
volume = "31",
pages = "1105--1111",
journal = "Journal of Pediatric Endocrinology and Metabolism",
issn = "0334-018X",
publisher = "Walter de Gruyter GmbH & Co. KG",
number = "10",

}

TY - JOUR

T1 - Comparison of serum 25-hydroxyvitamin D levels between radioimmunoassay and liquid chromatography-tandem mass spectrometry in infants and postpartum women

AU - Hara, Kaori

AU - Ikeda, Kazushige

AU - Koyama, Yuhei

AU - Wada, Yasuhiro

AU - Hasegawa, Tomonobu

PY - 2018/10/1

Y1 - 2018/10/1

N2 - Liquid chromatography-tandem mass spectrometry (LC-MS/MS) has become the gold standard for the measurement of serum 25-hydroxyvitamin D (25(OH)D) levels instead of the conventional method, radioimmunoassay (RIA). However, there was no study that compared RIA and LC-MS/MS for measuring serum 25(OH)D levels in infants and their mothers. The aim of this study was to assess the agreement of RIA and LC-MS/MS for measuring the serum levels in infants and postpartum women. This study enrolled 70 preterm infants, 113 term infants (134 samples), and 120 postpartum women. Serum concentration of 25(OH)D was measured by RIA and LC-MS/MS. We evaluated the correlation between RIA and LC-MS/MS. Also, we evaluated the bias between RIA and LC-MS/MS using Bland-Altman analysis. Sixty percent of preterm infants had serum 25(OH)D levels below the lower limit of quantification (LOQ) (4 ng/mL) and 90% of them were classified as vitamin D deficient. The serum 25(OH)D levels measured by RIA were significantly correlated with those measured by LC-MS/MS in all groups. According to the Bland-Altman plot, the serum 25(OH)D levels of infants measured by RIA had constant positive bias (mean±standard deviation [SD] [95% confidence interval, CI], preterm: +4.8± 2.4 ng/mL [4.2-5.4], term: +5.8±4.0 [5.1-6.5]) and proportional bias (preterm: r=0.44, p<0.01, term: r=0.50, p<0.01) compared with LC-MS/MS. The serum 25(OH)D levels of postpartum women measured by RIA had constant positive bias compared with LC-MS/MS, but no proportional bias was found. RIA demonstrated falsely high 25(OH)D levels when used for infants and postpartum women.

AB - Liquid chromatography-tandem mass spectrometry (LC-MS/MS) has become the gold standard for the measurement of serum 25-hydroxyvitamin D (25(OH)D) levels instead of the conventional method, radioimmunoassay (RIA). However, there was no study that compared RIA and LC-MS/MS for measuring serum 25(OH)D levels in infants and their mothers. The aim of this study was to assess the agreement of RIA and LC-MS/MS for measuring the serum levels in infants and postpartum women. This study enrolled 70 preterm infants, 113 term infants (134 samples), and 120 postpartum women. Serum concentration of 25(OH)D was measured by RIA and LC-MS/MS. We evaluated the correlation between RIA and LC-MS/MS. Also, we evaluated the bias between RIA and LC-MS/MS using Bland-Altman analysis. Sixty percent of preterm infants had serum 25(OH)D levels below the lower limit of quantification (LOQ) (4 ng/mL) and 90% of them were classified as vitamin D deficient. The serum 25(OH)D levels measured by RIA were significantly correlated with those measured by LC-MS/MS in all groups. According to the Bland-Altman plot, the serum 25(OH)D levels of infants measured by RIA had constant positive bias (mean±standard deviation [SD] [95% confidence interval, CI], preterm: +4.8± 2.4 ng/mL [4.2-5.4], term: +5.8±4.0 [5.1-6.5]) and proportional bias (preterm: r=0.44, p<0.01, term: r=0.50, p<0.01) compared with LC-MS/MS. The serum 25(OH)D levels of postpartum women measured by RIA had constant positive bias compared with LC-MS/MS, but no proportional bias was found. RIA demonstrated falsely high 25(OH)D levels when used for infants and postpartum women.

KW - 25-hydroxyvitamin D

KW - infants

KW - liquid chromatography tandem mass spectrometry

KW - radioimmunoassay

UR - http://www.scopus.com/inward/record.url?scp=85054294041&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85054294041&partnerID=8YFLogxK

U2 - 10.1515/jpem-2018-0275

DO - 10.1515/jpem-2018-0275

M3 - Article

C2 - 30231011

AN - SCOPUS:85054294041

VL - 31

SP - 1105

EP - 1111

JO - Journal of Pediatric Endocrinology and Metabolism

JF - Journal of Pediatric Endocrinology and Metabolism

SN - 0334-018X

IS - 10

ER -