Considerations for the manipulating technique and its indications of falloposcopic tuboplasty (FT)

Kou Sueoka, T. Kobayashi, H. Asada, T. Hashiba, N. Kuji, T. Miyazaki, S. Nozawa

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

The new mechanical balloon catheter system has been produced for the observation in the lumen of fallopian tubes and its treatment. Falloposcopic tuboplasty (FT) system was demonstrated and considered on the manipulating technique and its indications of the treatment. The success rate of tuboplasty depicts 70.7% in total 41 obstructive tubes from the patients of bilateral tubal occlusions. The success rates were rarely different depending on the location of occlusion within the distance of 10 cm from ostium through ampulla. This system has been determined useful not only for the treatment of tubal lumen but also for the observation of wide variety of pathological changes in more distal portion beyond the obstruction diagnosed by hysterosalpingography. When the eversion catheter had banched repeatedly at the stiff obstruction, the balloon pressure of everting catheter was inflated 1 a.t.m. up from initially 6 a.t.m. to 9 a.t.m., and the tubal patency was improved in the higher pressure. The manipulating length of each eversion was controlled less than 1 cm to avoid perforation which was the major complication specially on manipulating in higher pressure. Laparoscopy was also determined useful for the assistance to manipulate FT system.

Original languageEnglish
Pages (from-to)98-103
Number of pages6
JournalJapanese Journal of Fertility and Sterility
Volume40
Issue number2
Publication statusPublished - 1995

Fingerprint

Catheters
Pressure
Observation
Hysterosalpingography
Tubal Sterilization
Fallopian Tubes
Laparoscopy
Therapeutics

ASJC Scopus subject areas

  • Obstetrics and Gynaecology

Cite this

Sueoka, K., Kobayashi, T., Asada, H., Hashiba, T., Kuji, N., Miyazaki, T., & Nozawa, S. (1995). Considerations for the manipulating technique and its indications of falloposcopic tuboplasty (FT). Japanese Journal of Fertility and Sterility, 40(2), 98-103.

Considerations for the manipulating technique and its indications of falloposcopic tuboplasty (FT). / Sueoka, Kou; Kobayashi, T.; Asada, H.; Hashiba, T.; Kuji, N.; Miyazaki, T.; Nozawa, S.

In: Japanese Journal of Fertility and Sterility, Vol. 40, No. 2, 1995, p. 98-103.

Research output: Contribution to journalArticle

Sueoka, K, Kobayashi, T, Asada, H, Hashiba, T, Kuji, N, Miyazaki, T & Nozawa, S 1995, 'Considerations for the manipulating technique and its indications of falloposcopic tuboplasty (FT)', Japanese Journal of Fertility and Sterility, vol. 40, no. 2, pp. 98-103.
Sueoka, Kou ; Kobayashi, T. ; Asada, H. ; Hashiba, T. ; Kuji, N. ; Miyazaki, T. ; Nozawa, S. / Considerations for the manipulating technique and its indications of falloposcopic tuboplasty (FT). In: Japanese Journal of Fertility and Sterility. 1995 ; Vol. 40, No. 2. pp. 98-103.
@article{08a20fa3bc3a459aa0fec3e4f0f6da93,
title = "Considerations for the manipulating technique and its indications of falloposcopic tuboplasty (FT)",
abstract = "The new mechanical balloon catheter system has been produced for the observation in the lumen of fallopian tubes and its treatment. Falloposcopic tuboplasty (FT) system was demonstrated and considered on the manipulating technique and its indications of the treatment. The success rate of tuboplasty depicts 70.7{\%} in total 41 obstructive tubes from the patients of bilateral tubal occlusions. The success rates were rarely different depending on the location of occlusion within the distance of 10 cm from ostium through ampulla. This system has been determined useful not only for the treatment of tubal lumen but also for the observation of wide variety of pathological changes in more distal portion beyond the obstruction diagnosed by hysterosalpingography. When the eversion catheter had banched repeatedly at the stiff obstruction, the balloon pressure of everting catheter was inflated 1 a.t.m. up from initially 6 a.t.m. to 9 a.t.m., and the tubal patency was improved in the higher pressure. The manipulating length of each eversion was controlled less than 1 cm to avoid perforation which was the major complication specially on manipulating in higher pressure. Laparoscopy was also determined useful for the assistance to manipulate FT system.",
author = "Kou Sueoka and T. Kobayashi and H. Asada and T. Hashiba and N. Kuji and T. Miyazaki and S. Nozawa",
year = "1995",
language = "English",
volume = "40",
pages = "98--103",
journal = "Japanese Journal of Fertility and Sterility",
issn = "0029-0629",
publisher = "Nihon Funin Gakkai",
number = "2",

}

TY - JOUR

T1 - Considerations for the manipulating technique and its indications of falloposcopic tuboplasty (FT)

AU - Sueoka, Kou

AU - Kobayashi, T.

AU - Asada, H.

AU - Hashiba, T.

AU - Kuji, N.

AU - Miyazaki, T.

AU - Nozawa, S.

PY - 1995

Y1 - 1995

N2 - The new mechanical balloon catheter system has been produced for the observation in the lumen of fallopian tubes and its treatment. Falloposcopic tuboplasty (FT) system was demonstrated and considered on the manipulating technique and its indications of the treatment. The success rate of tuboplasty depicts 70.7% in total 41 obstructive tubes from the patients of bilateral tubal occlusions. The success rates were rarely different depending on the location of occlusion within the distance of 10 cm from ostium through ampulla. This system has been determined useful not only for the treatment of tubal lumen but also for the observation of wide variety of pathological changes in more distal portion beyond the obstruction diagnosed by hysterosalpingography. When the eversion catheter had banched repeatedly at the stiff obstruction, the balloon pressure of everting catheter was inflated 1 a.t.m. up from initially 6 a.t.m. to 9 a.t.m., and the tubal patency was improved in the higher pressure. The manipulating length of each eversion was controlled less than 1 cm to avoid perforation which was the major complication specially on manipulating in higher pressure. Laparoscopy was also determined useful for the assistance to manipulate FT system.

AB - The new mechanical balloon catheter system has been produced for the observation in the lumen of fallopian tubes and its treatment. Falloposcopic tuboplasty (FT) system was demonstrated and considered on the manipulating technique and its indications of the treatment. The success rate of tuboplasty depicts 70.7% in total 41 obstructive tubes from the patients of bilateral tubal occlusions. The success rates were rarely different depending on the location of occlusion within the distance of 10 cm from ostium through ampulla. This system has been determined useful not only for the treatment of tubal lumen but also for the observation of wide variety of pathological changes in more distal portion beyond the obstruction diagnosed by hysterosalpingography. When the eversion catheter had banched repeatedly at the stiff obstruction, the balloon pressure of everting catheter was inflated 1 a.t.m. up from initially 6 a.t.m. to 9 a.t.m., and the tubal patency was improved in the higher pressure. The manipulating length of each eversion was controlled less than 1 cm to avoid perforation which was the major complication specially on manipulating in higher pressure. Laparoscopy was also determined useful for the assistance to manipulate FT system.

UR - http://www.scopus.com/inward/record.url?scp=0028914432&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0028914432&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:0028914432

VL - 40

SP - 98

EP - 103

JO - Japanese Journal of Fertility and Sterility

JF - Japanese Journal of Fertility and Sterility

SN - 0029-0629

IS - 2

ER -