Corneal transplantation with donor corneas stored in moist chamber and chondroitin sulfate-containing medium

J. Shimazaki, M. Yamada, Kazuo Tsubota

Research output: Contribution to journalArticle

5 Citations (Scopus)

Abstract

Two donor cornea preservation methods, moist chamber and chondroitin sulfate-containing medium, were prospectively compared clinically. Paired corneas from 11 donors were divided into two groups: moist chamber group {mean preservation time 9.1 h) and Optisol group (mean preservation time 70.8 h). They were compared in terms of their clinical course, corneal thickness, and endothelial density. Recipient age, sex, and diseases were matched between the groups. Nine of 11 corneas in the moist chamber group, and 10 in the Optisol group remained clear at 6 months after surgery. Decreases of the endothelial density were 28.4% in the moist chamber group, and 30.1% in the Optisol group at 6 months after surgery. No differences were found in either endothelial density or corneal thickness throughout the observation period. It was shown that the corneoscleral preservation using chondroitin sulfate-containing medium was as useful as the conventional moist chamber preservation. Considering the requirement for longer donor preservation time, corneoscleral preservation should be adopted in areas other than the United States.

Original languageEnglish
Pages (from-to)104-108
Number of pages5
JournalCornea
Volume12
Issue number2
Publication statusPublished - 1993
Externally publishedYes

Fingerprint

Corneal Transplantation
Chondroitin Sulfates
Cornea
Research Design
Observation
Optisol

ASJC Scopus subject areas

  • Ophthalmology

Cite this

Corneal transplantation with donor corneas stored in moist chamber and chondroitin sulfate-containing medium. / Shimazaki, J.; Yamada, M.; Tsubota, Kazuo.

In: Cornea, Vol. 12, No. 2, 1993, p. 104-108.

Research output: Contribution to journalArticle

@article{0e839488a9cc46fdad63577bf4b489ec,
title = "Corneal transplantation with donor corneas stored in moist chamber and chondroitin sulfate-containing medium",
abstract = "Two donor cornea preservation methods, moist chamber and chondroitin sulfate-containing medium, were prospectively compared clinically. Paired corneas from 11 donors were divided into two groups: moist chamber group {mean preservation time 9.1 h) and Optisol group (mean preservation time 70.8 h). They were compared in terms of their clinical course, corneal thickness, and endothelial density. Recipient age, sex, and diseases were matched between the groups. Nine of 11 corneas in the moist chamber group, and 10 in the Optisol group remained clear at 6 months after surgery. Decreases of the endothelial density were 28.4{\%} in the moist chamber group, and 30.1{\%} in the Optisol group at 6 months after surgery. No differences were found in either endothelial density or corneal thickness throughout the observation period. It was shown that the corneoscleral preservation using chondroitin sulfate-containing medium was as useful as the conventional moist chamber preservation. Considering the requirement for longer donor preservation time, corneoscleral preservation should be adopted in areas other than the United States.",
author = "J. Shimazaki and M. Yamada and Kazuo Tsubota",
year = "1993",
language = "English",
volume = "12",
pages = "104--108",
journal = "Cornea",
issn = "0277-3740",
publisher = "Lippincott Williams and Wilkins",
number = "2",

}

TY - JOUR

T1 - Corneal transplantation with donor corneas stored in moist chamber and chondroitin sulfate-containing medium

AU - Shimazaki, J.

AU - Yamada, M.

AU - Tsubota, Kazuo

PY - 1993

Y1 - 1993

N2 - Two donor cornea preservation methods, moist chamber and chondroitin sulfate-containing medium, were prospectively compared clinically. Paired corneas from 11 donors were divided into two groups: moist chamber group {mean preservation time 9.1 h) and Optisol group (mean preservation time 70.8 h). They were compared in terms of their clinical course, corneal thickness, and endothelial density. Recipient age, sex, and diseases were matched between the groups. Nine of 11 corneas in the moist chamber group, and 10 in the Optisol group remained clear at 6 months after surgery. Decreases of the endothelial density were 28.4% in the moist chamber group, and 30.1% in the Optisol group at 6 months after surgery. No differences were found in either endothelial density or corneal thickness throughout the observation period. It was shown that the corneoscleral preservation using chondroitin sulfate-containing medium was as useful as the conventional moist chamber preservation. Considering the requirement for longer donor preservation time, corneoscleral preservation should be adopted in areas other than the United States.

AB - Two donor cornea preservation methods, moist chamber and chondroitin sulfate-containing medium, were prospectively compared clinically. Paired corneas from 11 donors were divided into two groups: moist chamber group {mean preservation time 9.1 h) and Optisol group (mean preservation time 70.8 h). They were compared in terms of their clinical course, corneal thickness, and endothelial density. Recipient age, sex, and diseases were matched between the groups. Nine of 11 corneas in the moist chamber group, and 10 in the Optisol group remained clear at 6 months after surgery. Decreases of the endothelial density were 28.4% in the moist chamber group, and 30.1% in the Optisol group at 6 months after surgery. No differences were found in either endothelial density or corneal thickness throughout the observation period. It was shown that the corneoscleral preservation using chondroitin sulfate-containing medium was as useful as the conventional moist chamber preservation. Considering the requirement for longer donor preservation time, corneoscleral preservation should be adopted in areas other than the United States.

UR - http://www.scopus.com/inward/record.url?scp=0027418006&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0027418006&partnerID=8YFLogxK

M3 - Article

C2 - 8500315

AN - SCOPUS:0027418006

VL - 12

SP - 104

EP - 108

JO - Cornea

JF - Cornea

SN - 0277-3740

IS - 2

ER -