Coronary angiography on multi detector-row CT; optimization for imaging method

Kozo Sato, Masahiro Jinzaki, Y. Tanami, S. Kuribayashi

Research output: Contribution to journalArticle

Abstract

The scanning technique used in our institute is as follows: The amount of contrast media is 3ml/s (flow rate) x scan time, and pre-scan delay is determined by test bolus. Retrospective reconstruction is given at diastolic phases on 70%, 75% and 80% of R-R interval at first, using multi-sector reconstruction method in the patients whose heart rate is higher than 65 and half reconstruction method in those who under 65.

Original languageEnglish
Pages (from-to)1627-1638
Number of pages12
JournalJapanese Journal of Clinical Radiology
Volume48
Issue number13
Publication statusPublished - 2003

Fingerprint

Coronary Angiography
Contrast Media
Heart Rate

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Coronary angiography on multi detector-row CT; optimization for imaging method. / Sato, Kozo; Jinzaki, Masahiro; Tanami, Y.; Kuribayashi, S.

In: Japanese Journal of Clinical Radiology, Vol. 48, No. 13, 2003, p. 1627-1638.

Research output: Contribution to journalArticle

@article{c6561cb06f37481ebd55ca5be6671993,
title = "Coronary angiography on multi detector-row CT; optimization for imaging method",
abstract = "The scanning technique used in our institute is as follows: The amount of contrast media is 3ml/s (flow rate) x scan time, and pre-scan delay is determined by test bolus. Retrospective reconstruction is given at diastolic phases on 70{\%}, 75{\%} and 80{\%} of R-R interval at first, using multi-sector reconstruction method in the patients whose heart rate is higher than 65 and half reconstruction method in those who under 65.",
author = "Kozo Sato and Masahiro Jinzaki and Y. Tanami and S. Kuribayashi",
year = "2003",
language = "English",
volume = "48",
pages = "1627--1638",
journal = "Japanese Journal of Clinical Radiology",
issn = "0009-9252",
publisher = "Kanehara Shuppan Co. Ltd",
number = "13",

}

TY - JOUR

T1 - Coronary angiography on multi detector-row CT; optimization for imaging method

AU - Sato, Kozo

AU - Jinzaki, Masahiro

AU - Tanami, Y.

AU - Kuribayashi, S.

PY - 2003

Y1 - 2003

N2 - The scanning technique used in our institute is as follows: The amount of contrast media is 3ml/s (flow rate) x scan time, and pre-scan delay is determined by test bolus. Retrospective reconstruction is given at diastolic phases on 70%, 75% and 80% of R-R interval at first, using multi-sector reconstruction method in the patients whose heart rate is higher than 65 and half reconstruction method in those who under 65.

AB - The scanning technique used in our institute is as follows: The amount of contrast media is 3ml/s (flow rate) x scan time, and pre-scan delay is determined by test bolus. Retrospective reconstruction is given at diastolic phases on 70%, 75% and 80% of R-R interval at first, using multi-sector reconstruction method in the patients whose heart rate is higher than 65 and half reconstruction method in those who under 65.

UR - http://www.scopus.com/inward/record.url?scp=0346249882&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0346249882&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:0346249882

VL - 48

SP - 1627

EP - 1638

JO - Japanese Journal of Clinical Radiology

JF - Japanese Journal of Clinical Radiology

SN - 0009-9252

IS - 13

ER -