Determination and quantitation of sulfonylurea and urea herbicides in water samples using liquid chromatography with electrospray ionization mass spectrometric detection

Eri Ayano, Hideko Kanazawa, Masanori Ando, Tetsuji Nishimura

Research output: Contribution to journalArticle

70 Citations (Scopus)

Abstract

A multianalyte method has been developed for the confirmation and quantitation of five sulfonylureas, bensulfuron-methyl, imazosulfuron, pyrazosulfuron-ethyl, flazasulfuron and halosulfuron-methyl, and for three ureas, siduron, dymron (daimuron) and diuron (DCMU) in water. Samples were extracted from water by off-line solid-phase extraction (SPE) with a polystyrene polymer cartridge (PS2), an ODS C18-bonded silica cartridge (C18) and an N-vinylpyrrolidone polymer cartridge (Oasis). Analyte determination and quantitation were performed by liquid chromatography with mass spectrometry (LC-MS). Extraction efficiency experiments demonstrated the ability of this method to extract sulfonylureas and ureas from water samples. Confirmatory analysis was carried out by LC-electrospray mass spectrometry (LC-ESI-MS) instrumentation equipped with a single-quadrupole mass filter. MS data acquisition was performed by a single or two-ion selected ion monitoring (SIM) program. It is required for confirmation that LC-MS retention times of the analytes are within 1% of the retention times of the standards, and that the molecular ion or characteristic fragment ion is present for each analyte. Fragment ions from distinctive structures must be obtained to identify and characterize specific herbicide molecules. These were obtained by controlled decomposition of sulfonylurea and urea adduct ions after suitably adjusting the electrical field in the desolvation chamber. The eight herbicides were also measured in fortified pure water (water purified by a milli-Q system), tap water and river water. Average recoveries of the eight analytes from water samples were in the range of 70-120% with relative standard deviations (R.S.D.s) of <20%. The limit of quantitation (LOQ) for each of the eight herbicides was between 10 and 100ngl-1.

Original languageEnglish
Pages (from-to)211-218
Number of pages8
JournalAnalytica Chimica Acta
Volume507
Issue number2
DOIs
Publication statusPublished - 2004 Apr 8

Fingerprint

Electrospray ionization
Liquid chromatography
Herbicides
Liquid Chromatography
urea
Urea
liquid chromatography
herbicide
ionization
Water
Ions
ion
Diuron
Mass spectrometry
mass spectrometry
water
polymer
Q system
Mass Spectrometry
Polymers

Keywords

  • LC-ESI-MS
  • SPE
  • Sulfonylurea herbicides
  • Urea herbicides
  • Water samples

ASJC Scopus subject areas

  • Biochemistry
  • Analytical Chemistry
  • Spectroscopy
  • Environmental Chemistry

Cite this

Determination and quantitation of sulfonylurea and urea herbicides in water samples using liquid chromatography with electrospray ionization mass spectrometric detection. / Ayano, Eri; Kanazawa, Hideko; Ando, Masanori; Nishimura, Tetsuji.

In: Analytica Chimica Acta, Vol. 507, No. 2, 08.04.2004, p. 211-218.

Research output: Contribution to journalArticle

@article{e9088e40469c48eca703d0ee0d14f343,
title = "Determination and quantitation of sulfonylurea and urea herbicides in water samples using liquid chromatography with electrospray ionization mass spectrometric detection",
abstract = "A multianalyte method has been developed for the confirmation and quantitation of five sulfonylureas, bensulfuron-methyl, imazosulfuron, pyrazosulfuron-ethyl, flazasulfuron and halosulfuron-methyl, and for three ureas, siduron, dymron (daimuron) and diuron (DCMU) in water. Samples were extracted from water by off-line solid-phase extraction (SPE) with a polystyrene polymer cartridge (PS2), an ODS C18-bonded silica cartridge (C18) and an N-vinylpyrrolidone polymer cartridge (Oasis). Analyte determination and quantitation were performed by liquid chromatography with mass spectrometry (LC-MS). Extraction efficiency experiments demonstrated the ability of this method to extract sulfonylureas and ureas from water samples. Confirmatory analysis was carried out by LC-electrospray mass spectrometry (LC-ESI-MS) instrumentation equipped with a single-quadrupole mass filter. MS data acquisition was performed by a single or two-ion selected ion monitoring (SIM) program. It is required for confirmation that LC-MS retention times of the analytes are within 1{\%} of the retention times of the standards, and that the molecular ion or characteristic fragment ion is present for each analyte. Fragment ions from distinctive structures must be obtained to identify and characterize specific herbicide molecules. These were obtained by controlled decomposition of sulfonylurea and urea adduct ions after suitably adjusting the electrical field in the desolvation chamber. The eight herbicides were also measured in fortified pure water (water purified by a milli-Q system), tap water and river water. Average recoveries of the eight analytes from water samples were in the range of 70-120{\%} with relative standard deviations (R.S.D.s) of <20{\%}. The limit of quantitation (LOQ) for each of the eight herbicides was between 10 and 100ngl-1.",
keywords = "LC-ESI-MS, SPE, Sulfonylurea herbicides, Urea herbicides, Water samples",
author = "Eri Ayano and Hideko Kanazawa and Masanori Ando and Tetsuji Nishimura",
year = "2004",
month = "4",
day = "8",
doi = "10.1016/j.aca.2003.11.027",
language = "English",
volume = "507",
pages = "211--218",
journal = "Analytica Chimica Acta",
issn = "0003-2670",
publisher = "Elsevier",
number = "2",

}

TY - JOUR

T1 - Determination and quantitation of sulfonylurea and urea herbicides in water samples using liquid chromatography with electrospray ionization mass spectrometric detection

AU - Ayano, Eri

AU - Kanazawa, Hideko

AU - Ando, Masanori

AU - Nishimura, Tetsuji

PY - 2004/4/8

Y1 - 2004/4/8

N2 - A multianalyte method has been developed for the confirmation and quantitation of five sulfonylureas, bensulfuron-methyl, imazosulfuron, pyrazosulfuron-ethyl, flazasulfuron and halosulfuron-methyl, and for three ureas, siduron, dymron (daimuron) and diuron (DCMU) in water. Samples were extracted from water by off-line solid-phase extraction (SPE) with a polystyrene polymer cartridge (PS2), an ODS C18-bonded silica cartridge (C18) and an N-vinylpyrrolidone polymer cartridge (Oasis). Analyte determination and quantitation were performed by liquid chromatography with mass spectrometry (LC-MS). Extraction efficiency experiments demonstrated the ability of this method to extract sulfonylureas and ureas from water samples. Confirmatory analysis was carried out by LC-electrospray mass spectrometry (LC-ESI-MS) instrumentation equipped with a single-quadrupole mass filter. MS data acquisition was performed by a single or two-ion selected ion monitoring (SIM) program. It is required for confirmation that LC-MS retention times of the analytes are within 1% of the retention times of the standards, and that the molecular ion or characteristic fragment ion is present for each analyte. Fragment ions from distinctive structures must be obtained to identify and characterize specific herbicide molecules. These were obtained by controlled decomposition of sulfonylurea and urea adduct ions after suitably adjusting the electrical field in the desolvation chamber. The eight herbicides were also measured in fortified pure water (water purified by a milli-Q system), tap water and river water. Average recoveries of the eight analytes from water samples were in the range of 70-120% with relative standard deviations (R.S.D.s) of <20%. The limit of quantitation (LOQ) for each of the eight herbicides was between 10 and 100ngl-1.

AB - A multianalyte method has been developed for the confirmation and quantitation of five sulfonylureas, bensulfuron-methyl, imazosulfuron, pyrazosulfuron-ethyl, flazasulfuron and halosulfuron-methyl, and for three ureas, siduron, dymron (daimuron) and diuron (DCMU) in water. Samples were extracted from water by off-line solid-phase extraction (SPE) with a polystyrene polymer cartridge (PS2), an ODS C18-bonded silica cartridge (C18) and an N-vinylpyrrolidone polymer cartridge (Oasis). Analyte determination and quantitation were performed by liquid chromatography with mass spectrometry (LC-MS). Extraction efficiency experiments demonstrated the ability of this method to extract sulfonylureas and ureas from water samples. Confirmatory analysis was carried out by LC-electrospray mass spectrometry (LC-ESI-MS) instrumentation equipped with a single-quadrupole mass filter. MS data acquisition was performed by a single or two-ion selected ion monitoring (SIM) program. It is required for confirmation that LC-MS retention times of the analytes are within 1% of the retention times of the standards, and that the molecular ion or characteristic fragment ion is present for each analyte. Fragment ions from distinctive structures must be obtained to identify and characterize specific herbicide molecules. These were obtained by controlled decomposition of sulfonylurea and urea adduct ions after suitably adjusting the electrical field in the desolvation chamber. The eight herbicides were also measured in fortified pure water (water purified by a milli-Q system), tap water and river water. Average recoveries of the eight analytes from water samples were in the range of 70-120% with relative standard deviations (R.S.D.s) of <20%. The limit of quantitation (LOQ) for each of the eight herbicides was between 10 and 100ngl-1.

KW - LC-ESI-MS

KW - SPE

KW - Sulfonylurea herbicides

KW - Urea herbicides

KW - Water samples

UR - http://www.scopus.com/inward/record.url?scp=1242328690&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=1242328690&partnerID=8YFLogxK

U2 - 10.1016/j.aca.2003.11.027

DO - 10.1016/j.aca.2003.11.027

M3 - Article

AN - SCOPUS:1242328690

VL - 507

SP - 211

EP - 218

JO - Analytica Chimica Acta

JF - Analytica Chimica Acta

SN - 0003-2670

IS - 2

ER -