Determination of selenium in the atmosphere by fluorescence HPLC with selenium-2, 3-diaminonaphthalene complex

Nakamura Masaru, Taka Suna Naohiko, Akagi Yasutaka, Tanaka Shigeru, Hashimoto Yoshikazu

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

A highly sensitive method was investigated for the determination of selenium in the atmosphere at trace levels using HPLC and a fluorescence detection system. The sample was decomposed with nitric acid and hydrogen peroxide. After the wet digestion, selenium exists predominantly in the form of selenium(VI). Therefore, it is necessary to reduce selenium(VI) to selenium(IV) before the 2, 3-diaminonaphthalene (DAN)-selenium(IV) reaction. However, nitric acid remaining in the sample solution interferes with the reduction of selenium(VI). In order to eliminate the interference by nitric acid, it was evaporated to near dryness after adding 1 ml of perchloric acid. After adding 5 ml of 6 M hydrochloric acid to the sample solution and the mixture was heated in a boiling water bath for 30 min to reduce selenium(VI) to selenium(IV), then warmed with 5 ml of 0.1% DAN and 1 ml of 0.1 M EDTA-NaF at 50°C for 20 min to form a piazselenol. The complex was extracted with 1 ml of cyclohexane. A 100 µl aliquot of the cyclohexane layer was analyzed by HPLC on a column (UNISIL ODS) with a mixture of cyclohexane and tetrahydrofuran (90/10, v/v) as the mobile phase. Se-DAN complex was fluorometrically detected with excitation at 375 nm and fluorescence at 520 nm. This method was applied to the standard sample of Vehicle Exhaust Particulates (NIES No. 8). The analytical result was in good agreement with the certified value. The detection limit of this method was 10pg/m3 for a 30 m3 air sampling volume. Therefore, this method can be satisfactorily applied to the determination of selenium in the atmosphere at trace levels.

Original languageEnglish
Pages (from-to)T49-T54
JournalBunseki Kagaku
Volume39
Issue number4
DOIs
Publication statusPublished - 1990

Fingerprint

Selenium
Fluorescence
Nitric Acid
2,3-diaminonaphthalene
Hydrochloric Acid
Edetic Acid
Boiling liquids
Hydrogen Peroxide
Sampling
Water

Keywords

  • elimination of nitric acid interference
  • highly sensitive determinationof selenium in the atmosphere
  • HPLC with fluorescence detector
  • selenium-2, 3-diaminonaphthalene complex

ASJC Scopus subject areas

  • Analytical Chemistry

Cite this

Determination of selenium in the atmosphere by fluorescence HPLC with selenium-2, 3-diaminonaphthalene complex. / Masaru, Nakamura; Naohiko, Taka Suna; Yasutaka, Akagi; Shigeru, Tanaka; Yoshikazu, Hashimoto.

In: Bunseki Kagaku, Vol. 39, No. 4, 1990, p. T49-T54.

Research output: Contribution to journalArticle

Masaru, Nakamura ; Naohiko, Taka Suna ; Yasutaka, Akagi ; Shigeru, Tanaka ; Yoshikazu, Hashimoto. / Determination of selenium in the atmosphere by fluorescence HPLC with selenium-2, 3-diaminonaphthalene complex. In: Bunseki Kagaku. 1990 ; Vol. 39, No. 4. pp. T49-T54.
@article{4cbd84c4b41b470d91f85f98446fc30a,
title = "Determination of selenium in the atmosphere by fluorescence HPLC with selenium-2, 3-diaminonaphthalene complex",
abstract = "A highly sensitive method was investigated for the determination of selenium in the atmosphere at trace levels using HPLC and a fluorescence detection system. The sample was decomposed with nitric acid and hydrogen peroxide. After the wet digestion, selenium exists predominantly in the form of selenium(VI). Therefore, it is necessary to reduce selenium(VI) to selenium(IV) before the 2, 3-diaminonaphthalene (DAN)-selenium(IV) reaction. However, nitric acid remaining in the sample solution interferes with the reduction of selenium(VI). In order to eliminate the interference by nitric acid, it was evaporated to near dryness after adding 1 ml of perchloric acid. After adding 5 ml of 6 M hydrochloric acid to the sample solution and the mixture was heated in a boiling water bath for 30 min to reduce selenium(VI) to selenium(IV), then warmed with 5 ml of 0.1{\%} DAN and 1 ml of 0.1 M EDTA-NaF at 50°C for 20 min to form a piazselenol. The complex was extracted with 1 ml of cyclohexane. A 100 µl aliquot of the cyclohexane layer was analyzed by HPLC on a column (UNISIL ODS) with a mixture of cyclohexane and tetrahydrofuran (90/10, v/v) as the mobile phase. Se-DAN complex was fluorometrically detected with excitation at 375 nm and fluorescence at 520 nm. This method was applied to the standard sample of Vehicle Exhaust Particulates (NIES No. 8). The analytical result was in good agreement with the certified value. The detection limit of this method was 10pg/m3 for a 30 m3 air sampling volume. Therefore, this method can be satisfactorily applied to the determination of selenium in the atmosphere at trace levels.",
keywords = "elimination of nitric acid interference, highly sensitive determinationof selenium in the atmosphere, HPLC with fluorescence detector, selenium-2, 3-diaminonaphthalene complex",
author = "Nakamura Masaru and Naohiko, {Taka Suna} and Akagi Yasutaka and Tanaka Shigeru and Hashimoto Yoshikazu",
year = "1990",
doi = "10.2116/bunsekikagaku.39.4_T49",
language = "English",
volume = "39",
pages = "T49--T54",
journal = "Bunseki Kagaku",
issn = "0525-1931",
publisher = "Japan Society for Analytical Chemistry",
number = "4",

}

TY - JOUR

T1 - Determination of selenium in the atmosphere by fluorescence HPLC with selenium-2, 3-diaminonaphthalene complex

AU - Masaru, Nakamura

AU - Naohiko, Taka Suna

AU - Yasutaka, Akagi

AU - Shigeru, Tanaka

AU - Yoshikazu, Hashimoto

PY - 1990

Y1 - 1990

N2 - A highly sensitive method was investigated for the determination of selenium in the atmosphere at trace levels using HPLC and a fluorescence detection system. The sample was decomposed with nitric acid and hydrogen peroxide. After the wet digestion, selenium exists predominantly in the form of selenium(VI). Therefore, it is necessary to reduce selenium(VI) to selenium(IV) before the 2, 3-diaminonaphthalene (DAN)-selenium(IV) reaction. However, nitric acid remaining in the sample solution interferes with the reduction of selenium(VI). In order to eliminate the interference by nitric acid, it was evaporated to near dryness after adding 1 ml of perchloric acid. After adding 5 ml of 6 M hydrochloric acid to the sample solution and the mixture was heated in a boiling water bath for 30 min to reduce selenium(VI) to selenium(IV), then warmed with 5 ml of 0.1% DAN and 1 ml of 0.1 M EDTA-NaF at 50°C for 20 min to form a piazselenol. The complex was extracted with 1 ml of cyclohexane. A 100 µl aliquot of the cyclohexane layer was analyzed by HPLC on a column (UNISIL ODS) with a mixture of cyclohexane and tetrahydrofuran (90/10, v/v) as the mobile phase. Se-DAN complex was fluorometrically detected with excitation at 375 nm and fluorescence at 520 nm. This method was applied to the standard sample of Vehicle Exhaust Particulates (NIES No. 8). The analytical result was in good agreement with the certified value. The detection limit of this method was 10pg/m3 for a 30 m3 air sampling volume. Therefore, this method can be satisfactorily applied to the determination of selenium in the atmosphere at trace levels.

AB - A highly sensitive method was investigated for the determination of selenium in the atmosphere at trace levels using HPLC and a fluorescence detection system. The sample was decomposed with nitric acid and hydrogen peroxide. After the wet digestion, selenium exists predominantly in the form of selenium(VI). Therefore, it is necessary to reduce selenium(VI) to selenium(IV) before the 2, 3-diaminonaphthalene (DAN)-selenium(IV) reaction. However, nitric acid remaining in the sample solution interferes with the reduction of selenium(VI). In order to eliminate the interference by nitric acid, it was evaporated to near dryness after adding 1 ml of perchloric acid. After adding 5 ml of 6 M hydrochloric acid to the sample solution and the mixture was heated in a boiling water bath for 30 min to reduce selenium(VI) to selenium(IV), then warmed with 5 ml of 0.1% DAN and 1 ml of 0.1 M EDTA-NaF at 50°C for 20 min to form a piazselenol. The complex was extracted with 1 ml of cyclohexane. A 100 µl aliquot of the cyclohexane layer was analyzed by HPLC on a column (UNISIL ODS) with a mixture of cyclohexane and tetrahydrofuran (90/10, v/v) as the mobile phase. Se-DAN complex was fluorometrically detected with excitation at 375 nm and fluorescence at 520 nm. This method was applied to the standard sample of Vehicle Exhaust Particulates (NIES No. 8). The analytical result was in good agreement with the certified value. The detection limit of this method was 10pg/m3 for a 30 m3 air sampling volume. Therefore, this method can be satisfactorily applied to the determination of selenium in the atmosphere at trace levels.

KW - elimination of nitric acid interference

KW - highly sensitive determinationof selenium in the atmosphere

KW - HPLC with fluorescence detector

KW - selenium-2, 3-diaminonaphthalene complex

UR - http://www.scopus.com/inward/record.url?scp=85008280397&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85008280397&partnerID=8YFLogxK

U2 - 10.2116/bunsekikagaku.39.4_T49

DO - 10.2116/bunsekikagaku.39.4_T49

M3 - Article

VL - 39

SP - T49-T54

JO - Bunseki Kagaku

JF - Bunseki Kagaku

SN - 0525-1931

IS - 4

ER -