DETERMINATION OF THE PVT-SURFACE OF WATER BASED ON THE MEASURED VALUES UP TO 1123 K AND 1 GPa.

Haruki Sato, Masahiko Uematsu, Koichi Watanabe

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

Presents the PVT-surface of water for temperatures from 273 to 1123 K up to a maximum pressure of 1 GPa given as a set of selected values. These selected values are derived from 6780 measured values by applying the method of error analysis previously proposed by the authors. In order to confirm the reliability of the method applied, the confidence intervals of the selected values as well as the results of the error analysis with respect to each set of measured values are closely examined. The validity of the selected values and their confidence intervals obtained as a result of this work are also confirmed both by examining the behavior of the proposed PVT-surface and comparing the selected values with the measured values.

Original languageEnglish
Pages (from-to)691-699
Number of pages9
JournalBulletin of the JSME
Volume24
Issue number190
Publication statusPublished - 1981 Apr
Externally publishedYes

Fingerprint

Error analysis
Water
Temperature

ASJC Scopus subject areas

  • Engineering(all)

Cite this

DETERMINATION OF THE PVT-SURFACE OF WATER BASED ON THE MEASURED VALUES UP TO 1123 K AND 1 GPa. / Sato, Haruki; Uematsu, Masahiko; Watanabe, Koichi.

In: Bulletin of the JSME, Vol. 24, No. 190, 04.1981, p. 691-699.

Research output: Contribution to journalArticle

Sato, H, Uematsu, M & Watanabe, K 1981, 'DETERMINATION OF THE PVT-SURFACE OF WATER BASED ON THE MEASURED VALUES UP TO 1123 K AND 1 GPa.', Bulletin of the JSME, vol. 24, no. 190, pp. 691-699.
Sato, Haruki ; Uematsu, Masahiko ; Watanabe, Koichi. / DETERMINATION OF THE PVT-SURFACE OF WATER BASED ON THE MEASURED VALUES UP TO 1123 K AND 1 GPa. In: Bulletin of the JSME. 1981 ; Vol. 24, No. 190. pp. 691-699.
@article{8f4f067096214aa4bf18302463465b3c,
title = "DETERMINATION OF THE PVT-SURFACE OF WATER BASED ON THE MEASURED VALUES UP TO 1123 K AND 1 GPa.",
abstract = "Presents the PVT-surface of water for temperatures from 273 to 1123 K up to a maximum pressure of 1 GPa given as a set of selected values. These selected values are derived from 6780 measured values by applying the method of error analysis previously proposed by the authors. In order to confirm the reliability of the method applied, the confidence intervals of the selected values as well as the results of the error analysis with respect to each set of measured values are closely examined. The validity of the selected values and their confidence intervals obtained as a result of this work are also confirmed both by examining the behavior of the proposed PVT-surface and comparing the selected values with the measured values.",
author = "Haruki Sato and Masahiko Uematsu and Koichi Watanabe",
year = "1981",
month = "4",
language = "English",
volume = "24",
pages = "691--699",
journal = "Bulletin of the JSME",
issn = "0021-3764",
publisher = "Society of Mechanical Engineers",
number = "190",

}

TY - JOUR

T1 - DETERMINATION OF THE PVT-SURFACE OF WATER BASED ON THE MEASURED VALUES UP TO 1123 K AND 1 GPa.

AU - Sato, Haruki

AU - Uematsu, Masahiko

AU - Watanabe, Koichi

PY - 1981/4

Y1 - 1981/4

N2 - Presents the PVT-surface of water for temperatures from 273 to 1123 K up to a maximum pressure of 1 GPa given as a set of selected values. These selected values are derived from 6780 measured values by applying the method of error analysis previously proposed by the authors. In order to confirm the reliability of the method applied, the confidence intervals of the selected values as well as the results of the error analysis with respect to each set of measured values are closely examined. The validity of the selected values and their confidence intervals obtained as a result of this work are also confirmed both by examining the behavior of the proposed PVT-surface and comparing the selected values with the measured values.

AB - Presents the PVT-surface of water for temperatures from 273 to 1123 K up to a maximum pressure of 1 GPa given as a set of selected values. These selected values are derived from 6780 measured values by applying the method of error analysis previously proposed by the authors. In order to confirm the reliability of the method applied, the confidence intervals of the selected values as well as the results of the error analysis with respect to each set of measured values are closely examined. The validity of the selected values and their confidence intervals obtained as a result of this work are also confirmed both by examining the behavior of the proposed PVT-surface and comparing the selected values with the measured values.

UR - http://www.scopus.com/inward/record.url?scp=0019548881&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0019548881&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:0019548881

VL - 24

SP - 691

EP - 699

JO - Bulletin of the JSME

JF - Bulletin of the JSME

SN - 0021-3764

IS - 190

ER -