Development of drift cage for PS-TEPC

Y. Fujita, T. Nagayoshi, J. Kikuchi, T. Doke, Kazuhiro Terasawa, K. Miuchi, T. Tanimori, H. Kubo, A. Takada, H. Nishimura, S. Sasaki, K. Saito, H. Tawara, T. Komiyama, H. Matsumoto, Y. Uchihori, H. Kitamura

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

To establish the new standard LET spectrometer we have developed the -TPC for the detection of cosmic-ray. As a result, through the simulation study the condition in the drift cage was greatly improved and the possibility of tissue equivalent drift cage was proved. Further experiments are needed to examine the specific prosperity of using tissue equivalent material for PS-TEPC. We plan to carry out a beam test of heavy ion irradiation using the heavyion medical accelerator complex (HIMAC) at the National Institute of Radiological Science (NIRS).

Original languageEnglish
Title of host publicationProceedings of the 21st Workshop on Radiation Detectors and Their Uses
Pages213-219
Number of pages7
Publication statusPublished - 2007
Externally publishedYes
Event21st Workshop on Radiation Detectors and Their Uses - Tsukuba, Ibaraki, Japan
Duration: 2007 Jan 312007 Feb 2

Other

Other21st Workshop on Radiation Detectors and Their Uses
CountryJapan
CityTsukuba, Ibaraki
Period07/1/3107/2/2

Fingerprint

Tissue
Cosmic rays
Ion bombardment
ion irradiation
Heavy ions
Particle accelerators
Spectrometers
cosmic rays
heavy ions
accelerators
spectrometers
simulation
Experiments

ASJC Scopus subject areas

  • Instrumentation

Cite this

Fujita, Y., Nagayoshi, T., Kikuchi, J., Doke, T., Terasawa, K., Miuchi, K., ... Kitamura, H. (2007). Development of drift cage for PS-TEPC. In Proceedings of the 21st Workshop on Radiation Detectors and Their Uses (pp. 213-219)

Development of drift cage for PS-TEPC. / Fujita, Y.; Nagayoshi, T.; Kikuchi, J.; Doke, T.; Terasawa, Kazuhiro; Miuchi, K.; Tanimori, T.; Kubo, H.; Takada, A.; Nishimura, H.; Sasaki, S.; Saito, K.; Tawara, H.; Komiyama, T.; Matsumoto, H.; Uchihori, Y.; Kitamura, H.

Proceedings of the 21st Workshop on Radiation Detectors and Their Uses. 2007. p. 213-219.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Fujita, Y, Nagayoshi, T, Kikuchi, J, Doke, T, Terasawa, K, Miuchi, K, Tanimori, T, Kubo, H, Takada, A, Nishimura, H, Sasaki, S, Saito, K, Tawara, H, Komiyama, T, Matsumoto, H, Uchihori, Y & Kitamura, H 2007, Development of drift cage for PS-TEPC. in Proceedings of the 21st Workshop on Radiation Detectors and Their Uses. pp. 213-219, 21st Workshop on Radiation Detectors and Their Uses, Tsukuba, Ibaraki, Japan, 07/1/31.
Fujita Y, Nagayoshi T, Kikuchi J, Doke T, Terasawa K, Miuchi K et al. Development of drift cage for PS-TEPC. In Proceedings of the 21st Workshop on Radiation Detectors and Their Uses. 2007. p. 213-219
Fujita, Y. ; Nagayoshi, T. ; Kikuchi, J. ; Doke, T. ; Terasawa, Kazuhiro ; Miuchi, K. ; Tanimori, T. ; Kubo, H. ; Takada, A. ; Nishimura, H. ; Sasaki, S. ; Saito, K. ; Tawara, H. ; Komiyama, T. ; Matsumoto, H. ; Uchihori, Y. ; Kitamura, H. / Development of drift cage for PS-TEPC. Proceedings of the 21st Workshop on Radiation Detectors and Their Uses. 2007. pp. 213-219
@inproceedings{d1b4e6fcdf654bc6966a2bbc6b412693,
title = "Development of drift cage for PS-TEPC",
abstract = "To establish the new standard LET spectrometer we have developed the -TPC for the detection of cosmic-ray. As a result, through the simulation study the condition in the drift cage was greatly improved and the possibility of tissue equivalent drift cage was proved. Further experiments are needed to examine the specific prosperity of using tissue equivalent material for PS-TEPC. We plan to carry out a beam test of heavy ion irradiation using the heavyion medical accelerator complex (HIMAC) at the National Institute of Radiological Science (NIRS).",
author = "Y. Fujita and T. Nagayoshi and J. Kikuchi and T. Doke and Kazuhiro Terasawa and K. Miuchi and T. Tanimori and H. Kubo and A. Takada and H. Nishimura and S. Sasaki and K. Saito and H. Tawara and T. Komiyama and H. Matsumoto and Y. Uchihori and H. Kitamura",
year = "2007",
language = "English",
pages = "213--219",
booktitle = "Proceedings of the 21st Workshop on Radiation Detectors and Their Uses",

}

TY - GEN

T1 - Development of drift cage for PS-TEPC

AU - Fujita, Y.

AU - Nagayoshi, T.

AU - Kikuchi, J.

AU - Doke, T.

AU - Terasawa, Kazuhiro

AU - Miuchi, K.

AU - Tanimori, T.

AU - Kubo, H.

AU - Takada, A.

AU - Nishimura, H.

AU - Sasaki, S.

AU - Saito, K.

AU - Tawara, H.

AU - Komiyama, T.

AU - Matsumoto, H.

AU - Uchihori, Y.

AU - Kitamura, H.

PY - 2007

Y1 - 2007

N2 - To establish the new standard LET spectrometer we have developed the -TPC for the detection of cosmic-ray. As a result, through the simulation study the condition in the drift cage was greatly improved and the possibility of tissue equivalent drift cage was proved. Further experiments are needed to examine the specific prosperity of using tissue equivalent material for PS-TEPC. We plan to carry out a beam test of heavy ion irradiation using the heavyion medical accelerator complex (HIMAC) at the National Institute of Radiological Science (NIRS).

AB - To establish the new standard LET spectrometer we have developed the -TPC for the detection of cosmic-ray. As a result, through the simulation study the condition in the drift cage was greatly improved and the possibility of tissue equivalent drift cage was proved. Further experiments are needed to examine the specific prosperity of using tissue equivalent material for PS-TEPC. We plan to carry out a beam test of heavy ion irradiation using the heavyion medical accelerator complex (HIMAC) at the National Institute of Radiological Science (NIRS).

UR - http://www.scopus.com/inward/record.url?scp=84881167616&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84881167616&partnerID=8YFLogxK

M3 - Conference contribution

AN - SCOPUS:84881167616

SP - 213

EP - 219

BT - Proceedings of the 21st Workshop on Radiation Detectors and Their Uses

ER -