Direct Instantaneous Distortion Minimization Control for Three Phase Converter

Yi Feng Chen, Kiyoshi Fujikawa, Hirokazu Kobayashi, Kouhei Ohnishi, A. Šabanović

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

In this paper, a novel instantaneous control strategy for the AC control loop of voltage-type converter is proposed in which two switching vectors are selected sequentially in one sampling period. Vector selection is based on control error minimization theorem to bring both fast response and low ripple. Switching timing is determined in real time according to the THD(Total Harmonic Distortion) minimization theorem with instantaneous THD definition as a direct evaluation function. With this algorithm, instantaneous control can be realized in almost constant switching frequency. For DC output voltage control, voltage square feedback with load power compensated algorithm is introduced to obtain global stability with fixed gain. Experimental investigation confirmed the validity of proposed control algorithms.

Original languageEnglish
Pages (from-to)823-830
Number of pages8
JournalIEEJ Transactions on Industry Applications
Volume117
Issue number7
DOIs
Publication statusPublished - 1997

Fingerprint

Harmonic distortion
Function evaluation
Electric potential
Switching frequency
Voltage control
Sampling
Feedback

ASJC Scopus subject areas

  • Industrial and Manufacturing Engineering
  • Electrical and Electronic Engineering

Cite this

Direct Instantaneous Distortion Minimization Control for Three Phase Converter. / Chen, Yi Feng; Fujikawa, Kiyoshi; Kobayashi, Hirokazu; Ohnishi, Kouhei; Šabanović, A.

In: IEEJ Transactions on Industry Applications, Vol. 117, No. 7, 1997, p. 823-830.

Research output: Contribution to journalArticle

Chen, YF, Fujikawa, K, Kobayashi, H, Ohnishi, K & Šabanović, A 1997, 'Direct Instantaneous Distortion Minimization Control for Three Phase Converter', IEEJ Transactions on Industry Applications, vol. 117, no. 7, pp. 823-830. https://doi.org/10.1541/ieejias.117.823
Chen, Yi Feng ; Fujikawa, Kiyoshi ; Kobayashi, Hirokazu ; Ohnishi, Kouhei ; Šabanović, A. / Direct Instantaneous Distortion Minimization Control for Three Phase Converter. In: IEEJ Transactions on Industry Applications. 1997 ; Vol. 117, No. 7. pp. 823-830.
@article{808909d2c4dd4203acc4919d6942b843,
title = "Direct Instantaneous Distortion Minimization Control for Three Phase Converter",
abstract = "In this paper, a novel instantaneous control strategy for the AC control loop of voltage-type converter is proposed in which two switching vectors are selected sequentially in one sampling period. Vector selection is based on control error minimization theorem to bring both fast response and low ripple. Switching timing is determined in real time according to the THD(Total Harmonic Distortion) minimization theorem with instantaneous THD definition as a direct evaluation function. With this algorithm, instantaneous control can be realized in almost constant switching frequency. For DC output voltage control, voltage square feedback with load power compensated algorithm is introduced to obtain global stability with fixed gain. Experimental investigation confirmed the validity of proposed control algorithms.",
author = "Chen, {Yi Feng} and Kiyoshi Fujikawa and Hirokazu Kobayashi and Kouhei Ohnishi and A. Šabanović",
year = "1997",
doi = "10.1541/ieejias.117.823",
language = "English",
volume = "117",
pages = "823--830",
journal = "IEEJ Transactions on Industry Applications",
issn = "0913-6339",
publisher = "The Institute of Electrical Engineers of Japan",
number = "7",

}

TY - JOUR

T1 - Direct Instantaneous Distortion Minimization Control for Three Phase Converter

AU - Chen, Yi Feng

AU - Fujikawa, Kiyoshi

AU - Kobayashi, Hirokazu

AU - Ohnishi, Kouhei

AU - Šabanović, A.

PY - 1997

Y1 - 1997

N2 - In this paper, a novel instantaneous control strategy for the AC control loop of voltage-type converter is proposed in which two switching vectors are selected sequentially in one sampling period. Vector selection is based on control error minimization theorem to bring both fast response and low ripple. Switching timing is determined in real time according to the THD(Total Harmonic Distortion) minimization theorem with instantaneous THD definition as a direct evaluation function. With this algorithm, instantaneous control can be realized in almost constant switching frequency. For DC output voltage control, voltage square feedback with load power compensated algorithm is introduced to obtain global stability with fixed gain. Experimental investigation confirmed the validity of proposed control algorithms.

AB - In this paper, a novel instantaneous control strategy for the AC control loop of voltage-type converter is proposed in which two switching vectors are selected sequentially in one sampling period. Vector selection is based on control error minimization theorem to bring both fast response and low ripple. Switching timing is determined in real time according to the THD(Total Harmonic Distortion) minimization theorem with instantaneous THD definition as a direct evaluation function. With this algorithm, instantaneous control can be realized in almost constant switching frequency. For DC output voltage control, voltage square feedback with load power compensated algorithm is introduced to obtain global stability with fixed gain. Experimental investigation confirmed the validity of proposed control algorithms.

UR - http://www.scopus.com/inward/record.url?scp=84880117359&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84880117359&partnerID=8YFLogxK

U2 - 10.1541/ieejias.117.823

DO - 10.1541/ieejias.117.823

M3 - Article

VL - 117

SP - 823

EP - 830

JO - IEEJ Transactions on Industry Applications

JF - IEEJ Transactions on Industry Applications

SN - 0913-6339

IS - 7