Distributed thermal conductance control for sensing and rendering thermal sensation on the palm

Yukiko Osawa, Seiichiro Katsura

Research output: Chapter in Book/Report/Conference proceedingConference contribution

1 Citation (Scopus)

Abstract

Sensing and rendering thermal sensation is important to the multimedia, communication, and medical field. For example, human health care system for monitoring and treating a body temperature distribution can be estimated by using the technique. In this research, the thermal interface using multiple heat sources for rendering thermal sensation is treated. In order to control a lot of heat sources in the thermal interface, the distributed control method is required to render spatial continuous sensation. The paper defined 'Distributed thermal conductance' that the relationship between heat sources, and heat flow on the palm can be freely changed depending on the connectivity between heat sources. The proposed method can be controlled the desired temperature distribution on the surface of the interface.

Original languageEnglish
Title of host publicationProceedings - 2018 IEEE 15th International Workshop on Advanced Motion Control, AMC 2018
PublisherInstitute of Electrical and Electronics Engineers Inc.
Pages328-333
Number of pages6
ISBN (Electronic)9781538619469
DOIs
Publication statusPublished - 2018 Jun 1
Event15th IEEE International Workshop on Advanced Motion Control, AMC 2018 - Tokyo, Japan
Duration: 2018 Mar 92018 Mar 11

Other

Other15th IEEE International Workshop on Advanced Motion Control, AMC 2018
CountryJapan
CityTokyo
Period18/3/918/3/11

Fingerprint

Conductance
Rendering
Heat Source
Sensing
Temperature Distribution
Multimedia Communication
Distributed Control
Heat Flow
Healthcare
Temperature distribution
Connectivity
Hot Temperature
Monitoring
Health care
Heat transfer
Communication

ASJC Scopus subject areas

  • Artificial Intelligence
  • Computer Science Applications
  • Mechanical Engineering
  • Control and Optimization

Cite this

Osawa, Y., & Katsura, S. (2018). Distributed thermal conductance control for sensing and rendering thermal sensation on the palm. In Proceedings - 2018 IEEE 15th International Workshop on Advanced Motion Control, AMC 2018 (pp. 328-333). Institute of Electrical and Electronics Engineers Inc.. https://doi.org/10.1109/AMC.2019.8371112

Distributed thermal conductance control for sensing and rendering thermal sensation on the palm. / Osawa, Yukiko; Katsura, Seiichiro.

Proceedings - 2018 IEEE 15th International Workshop on Advanced Motion Control, AMC 2018. Institute of Electrical and Electronics Engineers Inc., 2018. p. 328-333.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Osawa, Y & Katsura, S 2018, Distributed thermal conductance control for sensing and rendering thermal sensation on the palm. in Proceedings - 2018 IEEE 15th International Workshop on Advanced Motion Control, AMC 2018. Institute of Electrical and Electronics Engineers Inc., pp. 328-333, 15th IEEE International Workshop on Advanced Motion Control, AMC 2018, Tokyo, Japan, 18/3/9. https://doi.org/10.1109/AMC.2019.8371112
Osawa Y, Katsura S. Distributed thermal conductance control for sensing and rendering thermal sensation on the palm. In Proceedings - 2018 IEEE 15th International Workshop on Advanced Motion Control, AMC 2018. Institute of Electrical and Electronics Engineers Inc. 2018. p. 328-333 https://doi.org/10.1109/AMC.2019.8371112
Osawa, Yukiko ; Katsura, Seiichiro. / Distributed thermal conductance control for sensing and rendering thermal sensation on the palm. Proceedings - 2018 IEEE 15th International Workshop on Advanced Motion Control, AMC 2018. Institute of Electrical and Electronics Engineers Inc., 2018. pp. 328-333
@inproceedings{2babca98ef104a9ab58544faf7b2524c,
title = "Distributed thermal conductance control for sensing and rendering thermal sensation on the palm",
abstract = "Sensing and rendering thermal sensation is important to the multimedia, communication, and medical field. For example, human health care system for monitoring and treating a body temperature distribution can be estimated by using the technique. In this research, the thermal interface using multiple heat sources for rendering thermal sensation is treated. In order to control a lot of heat sources in the thermal interface, the distributed control method is required to render spatial continuous sensation. The paper defined 'Distributed thermal conductance' that the relationship between heat sources, and heat flow on the palm can be freely changed depending on the connectivity between heat sources. The proposed method can be controlled the desired temperature distribution on the surface of the interface.",
author = "Yukiko Osawa and Seiichiro Katsura",
year = "2018",
month = "6",
day = "1",
doi = "10.1109/AMC.2019.8371112",
language = "English",
pages = "328--333",
booktitle = "Proceedings - 2018 IEEE 15th International Workshop on Advanced Motion Control, AMC 2018",
publisher = "Institute of Electrical and Electronics Engineers Inc.",

}

TY - GEN

T1 - Distributed thermal conductance control for sensing and rendering thermal sensation on the palm

AU - Osawa, Yukiko

AU - Katsura, Seiichiro

PY - 2018/6/1

Y1 - 2018/6/1

N2 - Sensing and rendering thermal sensation is important to the multimedia, communication, and medical field. For example, human health care system for monitoring and treating a body temperature distribution can be estimated by using the technique. In this research, the thermal interface using multiple heat sources for rendering thermal sensation is treated. In order to control a lot of heat sources in the thermal interface, the distributed control method is required to render spatial continuous sensation. The paper defined 'Distributed thermal conductance' that the relationship between heat sources, and heat flow on the palm can be freely changed depending on the connectivity between heat sources. The proposed method can be controlled the desired temperature distribution on the surface of the interface.

AB - Sensing and rendering thermal sensation is important to the multimedia, communication, and medical field. For example, human health care system for monitoring and treating a body temperature distribution can be estimated by using the technique. In this research, the thermal interface using multiple heat sources for rendering thermal sensation is treated. In order to control a lot of heat sources in the thermal interface, the distributed control method is required to render spatial continuous sensation. The paper defined 'Distributed thermal conductance' that the relationship between heat sources, and heat flow on the palm can be freely changed depending on the connectivity between heat sources. The proposed method can be controlled the desired temperature distribution on the surface of the interface.

UR - http://www.scopus.com/inward/record.url?scp=85048828553&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85048828553&partnerID=8YFLogxK

U2 - 10.1109/AMC.2019.8371112

DO - 10.1109/AMC.2019.8371112

M3 - Conference contribution

AN - SCOPUS:85048828553

SP - 328

EP - 333

BT - Proceedings - 2018 IEEE 15th International Workshop on Advanced Motion Control, AMC 2018

PB - Institute of Electrical and Electronics Engineers Inc.

ER -