Dose–volume histogram analysis of brainstem necrosis in head and neck tumors treated using carbon-ion radiotherapy

Katsuyuki Shirai, Kyohei Fukata, Akiko Adachi, Jun ichi Saitoh, Atsushi Musha, Takanori Abe, Tatsuaki Kanai, Daijiro Kobayashi, Yuka Shigeta, Satoshi Yokoo, Kazuaki Chikamatsu, Tatsuya Ohno, Takashi Nakano

Research output: Contribution to journalArticle

4 Citations (Scopus)

Abstract

Background and purpose: We aimed to evaluate the relationship between brainstem necrosis and dose–volume histograms in patients with head and neck tumors after carbon-ion radiotherapy. Material and methods: We evaluated 85 patients with head and neck tumors who underwent carbon-ion radiotherapy and were followed-up for ≥12 months. Brainstem necrosis was evaluated using the Common Terminology Criteria for Adverse Events (version 4.0). Results: The median follow-up was 24 months, and four patients developed grade 1 brainstem necrosis, with 2-year and 3-year cumulative rates of 2.8% and 6.5%, respectively. Receiver operating characteristic curve analysis revealed the following significant cut-off values: a maximum brainstem dose of 48 Gy (relative biological effectiveness [RBE]), D1 cm3 of 27 Gy (RBE), V40 Gy (RBE) of 0.1 cm3, V30 Gy (RBE) of 0.7 cm3, and V20 Gy (RBE) of 1.4 cm3. Multivariate analysis revealed that V30 Gy (RBE) was most significantly associated with brainstem necrosis. The 2-year cumulative rates were 33% and 0% for V30 Gy (RBE) of ≥0.7 cm3 and <0.7 cm3, respectively (p < 0.001). Conclusions: The present study indicated that the dose constraints might help minimize brainstem necrosis after carbon-ion radiotherapy.

Original languageEnglish
Pages (from-to)36-40
Number of pages5
JournalRadiotherapy and Oncology
Volume125
Issue number1
DOIs
Publication statusPublished - 2017 Oct 1
Externally publishedYes

Fingerprint

Heavy Ion Radiotherapy
Relative Biological Effectiveness
Brain Stem
Necrosis
Neck
Head
Neoplasms
Terminology
ROC Curve
Multivariate Analysis

Keywords

  • Brainstem necrosis
  • Carbon-ion radiotherapy
  • Dose–volume histogram
  • Head and neck tumors
  • Non-squamous cell carcinoma

ASJC Scopus subject areas

  • Hematology
  • Oncology
  • Radiology Nuclear Medicine and imaging

Cite this

Dose–volume histogram analysis of brainstem necrosis in head and neck tumors treated using carbon-ion radiotherapy. / Shirai, Katsuyuki; Fukata, Kyohei; Adachi, Akiko; Saitoh, Jun ichi; Musha, Atsushi; Abe, Takanori; Kanai, Tatsuaki; Kobayashi, Daijiro; Shigeta, Yuka; Yokoo, Satoshi; Chikamatsu, Kazuaki; Ohno, Tatsuya; Nakano, Takashi.

In: Radiotherapy and Oncology, Vol. 125, No. 1, 01.10.2017, p. 36-40.

Research output: Contribution to journalArticle

Shirai, K, Fukata, K, Adachi, A, Saitoh, JI, Musha, A, Abe, T, Kanai, T, Kobayashi, D, Shigeta, Y, Yokoo, S, Chikamatsu, K, Ohno, T & Nakano, T 2017, 'Dose–volume histogram analysis of brainstem necrosis in head and neck tumors treated using carbon-ion radiotherapy', Radiotherapy and Oncology, vol. 125, no. 1, pp. 36-40. https://doi.org/10.1016/j.radonc.2017.08.014
Shirai, Katsuyuki ; Fukata, Kyohei ; Adachi, Akiko ; Saitoh, Jun ichi ; Musha, Atsushi ; Abe, Takanori ; Kanai, Tatsuaki ; Kobayashi, Daijiro ; Shigeta, Yuka ; Yokoo, Satoshi ; Chikamatsu, Kazuaki ; Ohno, Tatsuya ; Nakano, Takashi. / Dose–volume histogram analysis of brainstem necrosis in head and neck tumors treated using carbon-ion radiotherapy. In: Radiotherapy and Oncology. 2017 ; Vol. 125, No. 1. pp. 36-40.
@article{6a9320b3c6904a03ac8ec0aca118b878,
title = "Dose–volume histogram analysis of brainstem necrosis in head and neck tumors treated using carbon-ion radiotherapy",
abstract = "Background and purpose: We aimed to evaluate the relationship between brainstem necrosis and dose–volume histograms in patients with head and neck tumors after carbon-ion radiotherapy. Material and methods: We evaluated 85 patients with head and neck tumors who underwent carbon-ion radiotherapy and were followed-up for ≥12 months. Brainstem necrosis was evaluated using the Common Terminology Criteria for Adverse Events (version 4.0). Results: The median follow-up was 24 months, and four patients developed grade 1 brainstem necrosis, with 2-year and 3-year cumulative rates of 2.8{\%} and 6.5{\%}, respectively. Receiver operating characteristic curve analysis revealed the following significant cut-off values: a maximum brainstem dose of 48 Gy (relative biological effectiveness [RBE]), D1 cm3 of 27 Gy (RBE), V40 Gy (RBE) of 0.1 cm3, V30 Gy (RBE) of 0.7 cm3, and V20 Gy (RBE) of 1.4 cm3. Multivariate analysis revealed that V30 Gy (RBE) was most significantly associated with brainstem necrosis. The 2-year cumulative rates were 33{\%} and 0{\%} for V30 Gy (RBE) of ≥0.7 cm3 and <0.7 cm3, respectively (p < 0.001). Conclusions: The present study indicated that the dose constraints might help minimize brainstem necrosis after carbon-ion radiotherapy.",
keywords = "Brainstem necrosis, Carbon-ion radiotherapy, Dose–volume histogram, Head and neck tumors, Non-squamous cell carcinoma",
author = "Katsuyuki Shirai and Kyohei Fukata and Akiko Adachi and Saitoh, {Jun ichi} and Atsushi Musha and Takanori Abe and Tatsuaki Kanai and Daijiro Kobayashi and Yuka Shigeta and Satoshi Yokoo and Kazuaki Chikamatsu and Tatsuya Ohno and Takashi Nakano",
year = "2017",
month = "10",
day = "1",
doi = "10.1016/j.radonc.2017.08.014",
language = "English",
volume = "125",
pages = "36--40",
journal = "Radiotherapy and Oncology",
issn = "0167-8140",
publisher = "Elsevier Ireland Ltd",
number = "1",

}

TY - JOUR

T1 - Dose–volume histogram analysis of brainstem necrosis in head and neck tumors treated using carbon-ion radiotherapy

AU - Shirai, Katsuyuki

AU - Fukata, Kyohei

AU - Adachi, Akiko

AU - Saitoh, Jun ichi

AU - Musha, Atsushi

AU - Abe, Takanori

AU - Kanai, Tatsuaki

AU - Kobayashi, Daijiro

AU - Shigeta, Yuka

AU - Yokoo, Satoshi

AU - Chikamatsu, Kazuaki

AU - Ohno, Tatsuya

AU - Nakano, Takashi

PY - 2017/10/1

Y1 - 2017/10/1

N2 - Background and purpose: We aimed to evaluate the relationship between brainstem necrosis and dose–volume histograms in patients with head and neck tumors after carbon-ion radiotherapy. Material and methods: We evaluated 85 patients with head and neck tumors who underwent carbon-ion radiotherapy and were followed-up for ≥12 months. Brainstem necrosis was evaluated using the Common Terminology Criteria for Adverse Events (version 4.0). Results: The median follow-up was 24 months, and four patients developed grade 1 brainstem necrosis, with 2-year and 3-year cumulative rates of 2.8% and 6.5%, respectively. Receiver operating characteristic curve analysis revealed the following significant cut-off values: a maximum brainstem dose of 48 Gy (relative biological effectiveness [RBE]), D1 cm3 of 27 Gy (RBE), V40 Gy (RBE) of 0.1 cm3, V30 Gy (RBE) of 0.7 cm3, and V20 Gy (RBE) of 1.4 cm3. Multivariate analysis revealed that V30 Gy (RBE) was most significantly associated with brainstem necrosis. The 2-year cumulative rates were 33% and 0% for V30 Gy (RBE) of ≥0.7 cm3 and <0.7 cm3, respectively (p < 0.001). Conclusions: The present study indicated that the dose constraints might help minimize brainstem necrosis after carbon-ion radiotherapy.

AB - Background and purpose: We aimed to evaluate the relationship between brainstem necrosis and dose–volume histograms in patients with head and neck tumors after carbon-ion radiotherapy. Material and methods: We evaluated 85 patients with head and neck tumors who underwent carbon-ion radiotherapy and were followed-up for ≥12 months. Brainstem necrosis was evaluated using the Common Terminology Criteria for Adverse Events (version 4.0). Results: The median follow-up was 24 months, and four patients developed grade 1 brainstem necrosis, with 2-year and 3-year cumulative rates of 2.8% and 6.5%, respectively. Receiver operating characteristic curve analysis revealed the following significant cut-off values: a maximum brainstem dose of 48 Gy (relative biological effectiveness [RBE]), D1 cm3 of 27 Gy (RBE), V40 Gy (RBE) of 0.1 cm3, V30 Gy (RBE) of 0.7 cm3, and V20 Gy (RBE) of 1.4 cm3. Multivariate analysis revealed that V30 Gy (RBE) was most significantly associated with brainstem necrosis. The 2-year cumulative rates were 33% and 0% for V30 Gy (RBE) of ≥0.7 cm3 and <0.7 cm3, respectively (p < 0.001). Conclusions: The present study indicated that the dose constraints might help minimize brainstem necrosis after carbon-ion radiotherapy.

KW - Brainstem necrosis

KW - Carbon-ion radiotherapy

KW - Dose–volume histogram

KW - Head and neck tumors

KW - Non-squamous cell carcinoma

UR - http://www.scopus.com/inward/record.url?scp=85028510442&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85028510442&partnerID=8YFLogxK

U2 - 10.1016/j.radonc.2017.08.014

DO - 10.1016/j.radonc.2017.08.014

M3 - Article

C2 - 28867558

AN - SCOPUS:85028510442

VL - 125

SP - 36

EP - 40

JO - Radiotherapy and Oncology

JF - Radiotherapy and Oncology

SN - 0167-8140

IS - 1

ER -