Double-concave deformity of the polyethylene tibial post in posterior stabilized total knee arthroplasty

Yasuo Niki, Hideo Matsumoto, Fumihiro Yoshimine, Yoshiaki Toyama, Yasunori Suda, Scott A. Banks

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

This report describes a unique case of bilateral total knee arthroplasty necessitating revision of the polyethylene insert, which showed prominent marks on the tibial post resulting from repeated seiza-style sitting. The patient presented 7 years postoperatively with knee pain and flexion disturbance due to continuous joint effusion persisting for more than 4 months. Proliferating synovia throughout the joint revealed reactive synovitis to polyethylene particles. The retrieved polyethylene inserts displayed double-concave deformity of the tibial post with burnishing and creep in tibiofemoral articulation. The damage pattern of retrieved polyethylene inserts reflected the data from tibiofemoral contact location obtained using a shape-matching technique in the early postoperative phase. This case provides an example of damage to the polyethylene tibial post caused by a floor-sitting lifestyle and the potential clinical sequelae.

Original languageEnglish
JournalJournal of Arthroplasty
Volume25
Issue number3
DOIs
Publication statusPublished - 2010 Apr

Fingerprint

Knee Replacement Arthroplasties
Polyethylene
Joints
Synovitis
Synovial Fluid
Life Style
Knee
Pain

Keywords

  • Deep flexion
  • Floor-sitting lifestyle
  • Polyethylene insert
  • Shape matching
  • Tibial post
  • Total knee arthroplasty

ASJC Scopus subject areas

  • Orthopedics and Sports Medicine

Cite this

Double-concave deformity of the polyethylene tibial post in posterior stabilized total knee arthroplasty. / Niki, Yasuo; Matsumoto, Hideo; Yoshimine, Fumihiro; Toyama, Yoshiaki; Suda, Yasunori; Banks, Scott A.

In: Journal of Arthroplasty, Vol. 25, No. 3, 04.2010.

Research output: Contribution to journalArticle

Niki, Yasuo ; Matsumoto, Hideo ; Yoshimine, Fumihiro ; Toyama, Yoshiaki ; Suda, Yasunori ; Banks, Scott A. / Double-concave deformity of the polyethylene tibial post in posterior stabilized total knee arthroplasty. In: Journal of Arthroplasty. 2010 ; Vol. 25, No. 3.
@article{4b9c801ab0a247cbbc7d56a44f05e1c4,
title = "Double-concave deformity of the polyethylene tibial post in posterior stabilized total knee arthroplasty",
abstract = "This report describes a unique case of bilateral total knee arthroplasty necessitating revision of the polyethylene insert, which showed prominent marks on the tibial post resulting from repeated seiza-style sitting. The patient presented 7 years postoperatively with knee pain and flexion disturbance due to continuous joint effusion persisting for more than 4 months. Proliferating synovia throughout the joint revealed reactive synovitis to polyethylene particles. The retrieved polyethylene inserts displayed double-concave deformity of the tibial post with burnishing and creep in tibiofemoral articulation. The damage pattern of retrieved polyethylene inserts reflected the data from tibiofemoral contact location obtained using a shape-matching technique in the early postoperative phase. This case provides an example of damage to the polyethylene tibial post caused by a floor-sitting lifestyle and the potential clinical sequelae.",
keywords = "Deep flexion, Floor-sitting lifestyle, Polyethylene insert, Shape matching, Tibial post, Total knee arthroplasty",
author = "Yasuo Niki and Hideo Matsumoto and Fumihiro Yoshimine and Yoshiaki Toyama and Yasunori Suda and Banks, {Scott A.}",
year = "2010",
month = "4",
doi = "10.1016/j.arth.2009.02.012",
language = "English",
volume = "25",
journal = "Journal of Arthroplasty",
issn = "0883-5403",
publisher = "Churchill Livingstone",
number = "3",

}

TY - JOUR

T1 - Double-concave deformity of the polyethylene tibial post in posterior stabilized total knee arthroplasty

AU - Niki, Yasuo

AU - Matsumoto, Hideo

AU - Yoshimine, Fumihiro

AU - Toyama, Yoshiaki

AU - Suda, Yasunori

AU - Banks, Scott A.

PY - 2010/4

Y1 - 2010/4

N2 - This report describes a unique case of bilateral total knee arthroplasty necessitating revision of the polyethylene insert, which showed prominent marks on the tibial post resulting from repeated seiza-style sitting. The patient presented 7 years postoperatively with knee pain and flexion disturbance due to continuous joint effusion persisting for more than 4 months. Proliferating synovia throughout the joint revealed reactive synovitis to polyethylene particles. The retrieved polyethylene inserts displayed double-concave deformity of the tibial post with burnishing and creep in tibiofemoral articulation. The damage pattern of retrieved polyethylene inserts reflected the data from tibiofemoral contact location obtained using a shape-matching technique in the early postoperative phase. This case provides an example of damage to the polyethylene tibial post caused by a floor-sitting lifestyle and the potential clinical sequelae.

AB - This report describes a unique case of bilateral total knee arthroplasty necessitating revision of the polyethylene insert, which showed prominent marks on the tibial post resulting from repeated seiza-style sitting. The patient presented 7 years postoperatively with knee pain and flexion disturbance due to continuous joint effusion persisting for more than 4 months. Proliferating synovia throughout the joint revealed reactive synovitis to polyethylene particles. The retrieved polyethylene inserts displayed double-concave deformity of the tibial post with burnishing and creep in tibiofemoral articulation. The damage pattern of retrieved polyethylene inserts reflected the data from tibiofemoral contact location obtained using a shape-matching technique in the early postoperative phase. This case provides an example of damage to the polyethylene tibial post caused by a floor-sitting lifestyle and the potential clinical sequelae.

KW - Deep flexion

KW - Floor-sitting lifestyle

KW - Polyethylene insert

KW - Shape matching

KW - Tibial post

KW - Total knee arthroplasty

UR - http://www.scopus.com/inward/record.url?scp=77950521318&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77950521318&partnerID=8YFLogxK

U2 - 10.1016/j.arth.2009.02.012

DO - 10.1016/j.arth.2009.02.012

M3 - Article

VL - 25

JO - Journal of Arthroplasty

JF - Journal of Arthroplasty

SN - 0883-5403

IS - 3

ER -