Easy fabrication of microfluidic device using photosensitive sheet

Takeshi Ito, Kenichi Maruyama, Seishiro Ohya, Koji Suzuki

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

We studied characteristics of a microfluidic device fabricated by using a photosensitive sheet intercalated with substrates. Chemical resistance, electrical resistance and dissolution of ions dependent on process were evaluated. Considering the results, the microfluidic device was suitable for a disposable device. For such a device, we fabricated a micro bio-reactor integrated with an electrochemical detector. As the result of measuring the concentration of glucose by using the device, analytical curve of that was linear in range from 0.1 to 10 mM. copyright The Electrochemical Society.

Original languageEnglish
Title of host publicationECS Transactions
Pages417-425
Number of pages9
Volume3
Edition10
DOIs
Publication statusPublished - 2006
EventChemical Sensors 7 -and- MEMS/NEMS 7 - 210th Electrochemical Society Meeting - Cancun, Mexico
Duration: 2006 Oct 292006 Nov 3

Other

OtherChemical Sensors 7 -and- MEMS/NEMS 7 - 210th Electrochemical Society Meeting
CountryMexico
CityCancun
Period06/10/2906/11/3

Fingerprint

Microfluidics
Fabrication
Acoustic impedance
Chemical resistance
Glucose
Dissolution
Detectors
Ions
Substrates

ASJC Scopus subject areas

  • Engineering(all)

Cite this

Ito, T., Maruyama, K., Ohya, S., & Suzuki, K. (2006). Easy fabrication of microfluidic device using photosensitive sheet. In ECS Transactions (10 ed., Vol. 3, pp. 417-425) https://doi.org/10.1149/1.2357281

Easy fabrication of microfluidic device using photosensitive sheet. / Ito, Takeshi; Maruyama, Kenichi; Ohya, Seishiro; Suzuki, Koji.

ECS Transactions. Vol. 3 10. ed. 2006. p. 417-425.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Ito, T, Maruyama, K, Ohya, S & Suzuki, K 2006, Easy fabrication of microfluidic device using photosensitive sheet. in ECS Transactions. 10 edn, vol. 3, pp. 417-425, Chemical Sensors 7 -and- MEMS/NEMS 7 - 210th Electrochemical Society Meeting, Cancun, Mexico, 06/10/29. https://doi.org/10.1149/1.2357281
Ito T, Maruyama K, Ohya S, Suzuki K. Easy fabrication of microfluidic device using photosensitive sheet. In ECS Transactions. 10 ed. Vol. 3. 2006. p. 417-425 https://doi.org/10.1149/1.2357281
Ito, Takeshi ; Maruyama, Kenichi ; Ohya, Seishiro ; Suzuki, Koji. / Easy fabrication of microfluidic device using photosensitive sheet. ECS Transactions. Vol. 3 10. ed. 2006. pp. 417-425
@inproceedings{a71a7ec9e057460b9e2da18e79bc48ed,
title = "Easy fabrication of microfluidic device using photosensitive sheet",
abstract = "We studied characteristics of a microfluidic device fabricated by using a photosensitive sheet intercalated with substrates. Chemical resistance, electrical resistance and dissolution of ions dependent on process were evaluated. Considering the results, the microfluidic device was suitable for a disposable device. For such a device, we fabricated a micro bio-reactor integrated with an electrochemical detector. As the result of measuring the concentration of glucose by using the device, analytical curve of that was linear in range from 0.1 to 10 mM. copyright The Electrochemical Society.",
author = "Takeshi Ito and Kenichi Maruyama and Seishiro Ohya and Koji Suzuki",
year = "2006",
doi = "10.1149/1.2357281",
language = "English",
volume = "3",
pages = "417--425",
booktitle = "ECS Transactions",
edition = "10",

}

TY - GEN

T1 - Easy fabrication of microfluidic device using photosensitive sheet

AU - Ito, Takeshi

AU - Maruyama, Kenichi

AU - Ohya, Seishiro

AU - Suzuki, Koji

PY - 2006

Y1 - 2006

N2 - We studied characteristics of a microfluidic device fabricated by using a photosensitive sheet intercalated with substrates. Chemical resistance, electrical resistance and dissolution of ions dependent on process were evaluated. Considering the results, the microfluidic device was suitable for a disposable device. For such a device, we fabricated a micro bio-reactor integrated with an electrochemical detector. As the result of measuring the concentration of glucose by using the device, analytical curve of that was linear in range from 0.1 to 10 mM. copyright The Electrochemical Society.

AB - We studied characteristics of a microfluidic device fabricated by using a photosensitive sheet intercalated with substrates. Chemical resistance, electrical resistance and dissolution of ions dependent on process were evaluated. Considering the results, the microfluidic device was suitable for a disposable device. For such a device, we fabricated a micro bio-reactor integrated with an electrochemical detector. As the result of measuring the concentration of glucose by using the device, analytical curve of that was linear in range from 0.1 to 10 mM. copyright The Electrochemical Society.

UR - http://www.scopus.com/inward/record.url?scp=33847032162&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33847032162&partnerID=8YFLogxK

U2 - 10.1149/1.2357281

DO - 10.1149/1.2357281

M3 - Conference contribution

VL - 3

SP - 417

EP - 425