Abstract

This study proposes a new configuration consisting of two pairs of exciting magnetic coils and a pair of signal pickup electrodes with the higher driving frequencies than those of conventional electro-magnetic flowmeters. This rather complex configuration brings the meters a function of auto calibration and lowers the condition of the fluid conductivity. The analysis agrees well with experimental results and it clarifies the feasibility of the proposed configuration.

Original languageEnglish
Title of host publication2006 SICE-ICASE International Joint Conference
Pages4653-4658
Number of pages6
DOIs
Publication statusPublished - 2006
Event2006 SICE-ICASE International Joint Conference - Busan, Korea, Republic of
Duration: 2006 Oct 182006 Oct 21

Other

Other2006 SICE-ICASE International Joint Conference
CountryKorea, Republic of
CityBusan
Period06/10/1806/10/21

Fingerprint

Magnetic flowmeters
Pickups
Eddy currents
Calibration
Electrodes
Fluids

Keywords

  • Auto calibration
  • Electro-magnetic flowmeter
  • High frequency excitation

ASJC Scopus subject areas

  • Computer Science Applications
  • Control and Systems Engineering
  • Electrical and Electronic Engineering

Cite this

Honda, S., & Yamamoto, T. (2006). Electro-magnetic flowmeters using eddy currents. In 2006 SICE-ICASE International Joint Conference (pp. 4653-4658). [4108499] https://doi.org/10.1109/SICE.2006.315180

Electro-magnetic flowmeters using eddy currents. / Honda, Satoshi; Yamamoto, Tomoshige.

2006 SICE-ICASE International Joint Conference. 2006. p. 4653-4658 4108499.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Honda, S & Yamamoto, T 2006, Electro-magnetic flowmeters using eddy currents. in 2006 SICE-ICASE International Joint Conference., 4108499, pp. 4653-4658, 2006 SICE-ICASE International Joint Conference, Busan, Korea, Republic of, 06/10/18. https://doi.org/10.1109/SICE.2006.315180
Honda S, Yamamoto T. Electro-magnetic flowmeters using eddy currents. In 2006 SICE-ICASE International Joint Conference. 2006. p. 4653-4658. 4108499 https://doi.org/10.1109/SICE.2006.315180
Honda, Satoshi ; Yamamoto, Tomoshige. / Electro-magnetic flowmeters using eddy currents. 2006 SICE-ICASE International Joint Conference. 2006. pp. 4653-4658
@inproceedings{b2c3a59cbf4a4336a9c6bac521ac0f01,
title = "Electro-magnetic flowmeters using eddy currents",
abstract = "This study proposes a new configuration consisting of two pairs of exciting magnetic coils and a pair of signal pickup electrodes with the higher driving frequencies than those of conventional electro-magnetic flowmeters. This rather complex configuration brings the meters a function of auto calibration and lowers the condition of the fluid conductivity. The analysis agrees well with experimental results and it clarifies the feasibility of the proposed configuration.",
keywords = "Auto calibration, Electro-magnetic flowmeter, High frequency excitation",
author = "Satoshi Honda and Tomoshige Yamamoto",
year = "2006",
doi = "10.1109/SICE.2006.315180",
language = "English",
isbn = "8995003855",
pages = "4653--4658",
booktitle = "2006 SICE-ICASE International Joint Conference",

}

TY - GEN

T1 - Electro-magnetic flowmeters using eddy currents

AU - Honda, Satoshi

AU - Yamamoto, Tomoshige

PY - 2006

Y1 - 2006

N2 - This study proposes a new configuration consisting of two pairs of exciting magnetic coils and a pair of signal pickup electrodes with the higher driving frequencies than those of conventional electro-magnetic flowmeters. This rather complex configuration brings the meters a function of auto calibration and lowers the condition of the fluid conductivity. The analysis agrees well with experimental results and it clarifies the feasibility of the proposed configuration.

AB - This study proposes a new configuration consisting of two pairs of exciting magnetic coils and a pair of signal pickup electrodes with the higher driving frequencies than those of conventional electro-magnetic flowmeters. This rather complex configuration brings the meters a function of auto calibration and lowers the condition of the fluid conductivity. The analysis agrees well with experimental results and it clarifies the feasibility of the proposed configuration.

KW - Auto calibration

KW - Electro-magnetic flowmeter

KW - High frequency excitation

UR - http://www.scopus.com/inward/record.url?scp=34250769548&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=34250769548&partnerID=8YFLogxK

U2 - 10.1109/SICE.2006.315180

DO - 10.1109/SICE.2006.315180

M3 - Conference contribution

AN - SCOPUS:34250769548

SN - 8995003855

SN - 9788995003855

SP - 4653

EP - 4658

BT - 2006 SICE-ICASE International Joint Conference

ER -