Electrochemical detection of hydrogen peroxide at platinum-modified diamond electrodes for an application in melamine strip tests

Bakhadir Rismetov, Tribidasari A. Ivandini, Endang Saepudin, Yasuaki Einaga

Research output: Contribution to journalArticle

26 Citations (Scopus)

Abstract

Electrochemical detection of hydrogen peroxide (H2O2) at a platinum-deposited boron doped diamond was studied for an application in melamine strip test. Deposition of Pt particles at a boron-doped diamond surface was performed using cyclic voltammetry method. The method was also used for electrochemical measurements. The oxidation-reduction peak currents of H 2O2 at + 0.6 V and - 0.1 V (vs. Ag/AgCl), respectively were found to be linear in the concentration range of 0.05-20 mM (R2 = 0.99). Linearity was also observed to be dependent on horseradish peroxidase (HRP) concentration in the constant concentration of H2O2. The method was then applied in immunochromatographic strip test for melamine detection to determine the activity of HRP labeled at melamine antibody. Taking an assumption that the activity of HRP was equivalent to melamine concentration, linearity of the current responses to the concentrations of standard melamine solutions in the range of 5-100 μg/ml could be achieved. Limit of detection of 0.51 μg/ml was estimated. The obtained results demonstrated that the designed biosensor for detection of H2O2 could be applied for the quantitative and selective detection of melamine.

Original languageEnglish
Pages (from-to)88-95
Number of pages8
JournalDiamond and Related Materials
Volume48
DOIs
Publication statusPublished - 2014

Fingerprint

melamine
Diamond
Melamine
Platinum
hydrogen peroxide
Hydrogen peroxide
Hydrogen Peroxide
Diamonds
strip
platinum
diamonds
Electrodes
electrodes
Horseradish Peroxidase
Boron
linearity
boron
antibodies
bioinstrumentation
Biosensors

Keywords

  • Horseradish peroxidase
  • Hydrogen peroxide
  • Immunochromatographic strip test
  • Melamine
  • Pt-modified diamond

ASJC Scopus subject areas

  • Electronic, Optical and Magnetic Materials
  • Materials Chemistry
  • Electrical and Electronic Engineering
  • Mechanical Engineering
  • Physics and Astronomy(all)
  • Chemistry(all)

Cite this

Electrochemical detection of hydrogen peroxide at platinum-modified diamond electrodes for an application in melamine strip tests. / Rismetov, Bakhadir; Ivandini, Tribidasari A.; Saepudin, Endang; Einaga, Yasuaki.

In: Diamond and Related Materials, Vol. 48, 2014, p. 88-95.

Research output: Contribution to journalArticle

@article{03d5edca8dc14ceb9a86875c0458f4c3,
title = "Electrochemical detection of hydrogen peroxide at platinum-modified diamond electrodes for an application in melamine strip tests",
abstract = "Electrochemical detection of hydrogen peroxide (H2O2) at a platinum-deposited boron doped diamond was studied for an application in melamine strip test. Deposition of Pt particles at a boron-doped diamond surface was performed using cyclic voltammetry method. The method was also used for electrochemical measurements. The oxidation-reduction peak currents of H 2O2 at + 0.6 V and - 0.1 V (vs. Ag/AgCl), respectively were found to be linear in the concentration range of 0.05-20 mM (R2 = 0.99). Linearity was also observed to be dependent on horseradish peroxidase (HRP) concentration in the constant concentration of H2O2. The method was then applied in immunochromatographic strip test for melamine detection to determine the activity of HRP labeled at melamine antibody. Taking an assumption that the activity of HRP was equivalent to melamine concentration, linearity of the current responses to the concentrations of standard melamine solutions in the range of 5-100 μg/ml could be achieved. Limit of detection of 0.51 μg/ml was estimated. The obtained results demonstrated that the designed biosensor for detection of H2O2 could be applied for the quantitative and selective detection of melamine.",
keywords = "Horseradish peroxidase, Hydrogen peroxide, Immunochromatographic strip test, Melamine, Pt-modified diamond",
author = "Bakhadir Rismetov and Ivandini, {Tribidasari A.} and Endang Saepudin and Yasuaki Einaga",
year = "2014",
doi = "10.1016/j.diamond.2014.07.003",
language = "English",
volume = "48",
pages = "88--95",
journal = "Diamond and Related Materials",
issn = "0925-9635",
publisher = "Elsevier BV",

}

TY - JOUR

T1 - Electrochemical detection of hydrogen peroxide at platinum-modified diamond electrodes for an application in melamine strip tests

AU - Rismetov, Bakhadir

AU - Ivandini, Tribidasari A.

AU - Saepudin, Endang

AU - Einaga, Yasuaki

PY - 2014

Y1 - 2014

N2 - Electrochemical detection of hydrogen peroxide (H2O2) at a platinum-deposited boron doped diamond was studied for an application in melamine strip test. Deposition of Pt particles at a boron-doped diamond surface was performed using cyclic voltammetry method. The method was also used for electrochemical measurements. The oxidation-reduction peak currents of H 2O2 at + 0.6 V and - 0.1 V (vs. Ag/AgCl), respectively were found to be linear in the concentration range of 0.05-20 mM (R2 = 0.99). Linearity was also observed to be dependent on horseradish peroxidase (HRP) concentration in the constant concentration of H2O2. The method was then applied in immunochromatographic strip test for melamine detection to determine the activity of HRP labeled at melamine antibody. Taking an assumption that the activity of HRP was equivalent to melamine concentration, linearity of the current responses to the concentrations of standard melamine solutions in the range of 5-100 μg/ml could be achieved. Limit of detection of 0.51 μg/ml was estimated. The obtained results demonstrated that the designed biosensor for detection of H2O2 could be applied for the quantitative and selective detection of melamine.

AB - Electrochemical detection of hydrogen peroxide (H2O2) at a platinum-deposited boron doped diamond was studied for an application in melamine strip test. Deposition of Pt particles at a boron-doped diamond surface was performed using cyclic voltammetry method. The method was also used for electrochemical measurements. The oxidation-reduction peak currents of H 2O2 at + 0.6 V and - 0.1 V (vs. Ag/AgCl), respectively were found to be linear in the concentration range of 0.05-20 mM (R2 = 0.99). Linearity was also observed to be dependent on horseradish peroxidase (HRP) concentration in the constant concentration of H2O2. The method was then applied in immunochromatographic strip test for melamine detection to determine the activity of HRP labeled at melamine antibody. Taking an assumption that the activity of HRP was equivalent to melamine concentration, linearity of the current responses to the concentrations of standard melamine solutions in the range of 5-100 μg/ml could be achieved. Limit of detection of 0.51 μg/ml was estimated. The obtained results demonstrated that the designed biosensor for detection of H2O2 could be applied for the quantitative and selective detection of melamine.

KW - Horseradish peroxidase

KW - Hydrogen peroxide

KW - Immunochromatographic strip test

KW - Melamine

KW - Pt-modified diamond

UR - http://www.scopus.com/inward/record.url?scp=84905400037&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84905400037&partnerID=8YFLogxK

U2 - 10.1016/j.diamond.2014.07.003

DO - 10.1016/j.diamond.2014.07.003

M3 - Article

VL - 48

SP - 88

EP - 95

JO - Diamond and Related Materials

JF - Diamond and Related Materials

SN - 0925-9635

ER -