Estimation of 3-D flow tomography through Electro Magnetic Induction

T. Katoh, S. Honda

Research output: Contribution to conferencePaperpeer-review

2 Citations (Scopus)

Abstract

Electromagnetic flowmeters, which have been one of the standard instrument to measure liquid flowrate in industry, are applied to tomographic imaging of flow velocity field. It is possible to evaluate velocity profiles through the proper design of the magnetic field. In this paper, we propose a new design of the 3-D field excitation with two sets of eight magnetic poles and of eight signal pick-up electrodes. From the simulation study under a laminar swirling flow, it is clarified that the reconstruction of 3-D velocity distribution can be achieved.

Original languageEnglish
Pages1599-1605
Number of pages7
Publication statusPublished - 2004 Dec 1
EventSICE Annual Conference 2004 - Sapporo, Japan
Duration: 2004 Aug 42004 Aug 6

Other

OtherSICE Annual Conference 2004
Country/TerritoryJapan
CitySapporo
Period04/8/404/8/6

Keywords

  • Flow tomography
  • Inverse problem
  • Magnetic Induction
  • Reconstruction

ASJC Scopus subject areas

  • Control and Systems Engineering
  • Computer Science Applications
  • Electrical and Electronic Engineering

Fingerprint

Dive into the research topics of 'Estimation of 3-D flow tomography through Electro Magnetic Induction'. Together they form a unique fingerprint.