Evaluation of sulfur dioxide poisoning for LSCF cathodes

F. Wang, K. Yamaji, D. H. Cho, T. Shimonosono, M. Nishi, H. Kishimoto, M. E. Brito, T. Horita, H. Yokokawa

Research output: Contribution to journalArticle

30 Citations (Scopus)

Abstract

Sulfur poisoning behavior of La0.6Sr0.4Co 0.2Fe0.8O3-δ (LSCF6428) cathode was investigated at T = 1073 K (800°C) under 0.1 ppm of SO2-air mixture gas; the amount of supplied SO2 was controlled by changing the flow rate. Two stages of the performance degradation were found: a rapid degradation at the early stage and a subsequent monotonic degradation. The elemental distributions of SrSO4 showed a strong correlation between the electrochemically active sites and SrSO4 reaction sites in the vicinity of the LSCF6428/10GDC interfaces. Considerations were made to attribute the first and the second stages of performance degradation to the SO 2 adsorption and the SrSO4 formation, respectively. The SO2 adsorption mechanism was discussed in terms of the high concentration of oxide ion vacancies in the electrochemically active region under the cathodic polarization condition.

Original languageEnglish
Pages (from-to)520-525
Number of pages6
JournalFuel Cells
Volume13
Issue number4
DOIs
Publication statusPublished - 2013 Aug 1

Keywords

  • Cathode
  • LSCF
  • Solid Oxide Fuel Cells (SOFCs)
  • Sulfur Poisoning

ASJC Scopus subject areas

  • Renewable Energy, Sustainability and the Environment
  • Energy Engineering and Power Technology

Fingerprint Dive into the research topics of 'Evaluation of sulfur dioxide poisoning for LSCF cathodes'. Together they form a unique fingerprint.

  • Cite this

    Wang, F., Yamaji, K., Cho, D. H., Shimonosono, T., Nishi, M., Kishimoto, H., Brito, M. E., Horita, T., & Yokokawa, H. (2013). Evaluation of sulfur dioxide poisoning for LSCF cathodes. Fuel Cells, 13(4), 520-525. https://doi.org/10.1002/fuce.201200172