PURPOSE: To examine the interaction of echo train length and interecho spacing and their effects on image quality and contrast in fast spin-echo sequences of the cervical spine. METHODS: Forty-three patients with suspected cervical disk disease were prospectively evaluated with fast spin-echo with varying echo train lengths and interecho spacing. A flow phantom was used to confirm findings related to cerebrospinal fluid pulsation. Parameters were manipulated to adjust contrast, signal-to-noise ratio, the effects of artifacts, and the speed of acquisition. RESULTS: In general, increasing echo train length increased homogeneity and high intensity of cerebrospinal fluid signal and reduced acquisition time; however, it decreased the signal-to- noise ratio of cerebrospinal fluid and cord and increased blurring, and, to a lesser extent, edge enhancement, and 'truncation-type' artifact. Increasing interecho space permitted the use of longer echo times but minimally decreased contrast and signal-to-noise ratio of cord and cerebrospinal fluid. In addition, increasing echo spacing increased blurring, edge enhancement, truncation-type, magnetic susceptibility, and motion artifacts. CONCLUSIONS: For cervical spine imaging, a long echo train length and short echo spacing partially compensate for cerebrospinal fluid flow and produce the best myelographic effect but must be modulated by other constraints, such as artifact production or technical capabilities.

Original languageEnglish
Pages (from-to)1203-1213
Number of pages11
JournalAmerican Journal of Neuroradiology
Volume14
Issue number5
Publication statusPublished - 1993
Externally publishedYes

Fingerprint

Cerebrospinal Fluid
Spine
Artifacts
Magnetic Resonance Imaging
Signal-To-Noise Ratio

ASJC Scopus subject areas

  • Clinical Neurology
  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology

Cite this

Fast spin-echo MR imaging of the cervical spine : Influence of echo train length and echo spacing on image contrast and quality. / Sze, G.; Kawamura, Y.; Negishi, C.; Constable, R. T.; Merriam, M.; Oshio, Koichi; Jolesz, F.

In: American Journal of Neuroradiology, Vol. 14, No. 5, 1993, p. 1203-1213.

Research output: Contribution to journalArticle

Sze, G. ; Kawamura, Y. ; Negishi, C. ; Constable, R. T. ; Merriam, M. ; Oshio, Koichi ; Jolesz, F. / Fast spin-echo MR imaging of the cervical spine : Influence of echo train length and echo spacing on image contrast and quality. In: American Journal of Neuroradiology. 1993 ; Vol. 14, No. 5. pp. 1203-1213.
@article{5eed14c4e45a4d5f95cabbb94fbaeb50,
title = "Fast spin-echo MR imaging of the cervical spine: Influence of echo train length and echo spacing on image contrast and quality",
abstract = "PURPOSE: To examine the interaction of echo train length and interecho spacing and their effects on image quality and contrast in fast spin-echo sequences of the cervical spine. METHODS: Forty-three patients with suspected cervical disk disease were prospectively evaluated with fast spin-echo with varying echo train lengths and interecho spacing. A flow phantom was used to confirm findings related to cerebrospinal fluid pulsation. Parameters were manipulated to adjust contrast, signal-to-noise ratio, the effects of artifacts, and the speed of acquisition. RESULTS: In general, increasing echo train length increased homogeneity and high intensity of cerebrospinal fluid signal and reduced acquisition time; however, it decreased the signal-to- noise ratio of cerebrospinal fluid and cord and increased blurring, and, to a lesser extent, edge enhancement, and 'truncation-type' artifact. Increasing interecho space permitted the use of longer echo times but minimally decreased contrast and signal-to-noise ratio of cord and cerebrospinal fluid. In addition, increasing echo spacing increased blurring, edge enhancement, truncation-type, magnetic susceptibility, and motion artifacts. CONCLUSIONS: For cervical spine imaging, a long echo train length and short echo spacing partially compensate for cerebrospinal fluid flow and produce the best myelographic effect but must be modulated by other constraints, such as artifact production or technical capabilities.",
author = "G. Sze and Y. Kawamura and C. Negishi and Constable, {R. T.} and M. Merriam and Koichi Oshio and F. Jolesz",
year = "1993",
language = "English",
volume = "14",
pages = "1203--1213",
journal = "American Journal of Neuroradiology",
issn = "0195-6108",
publisher = "American Society of Neuroradiology",
number = "5",

}

TY - JOUR

T1 - Fast spin-echo MR imaging of the cervical spine

T2 - Influence of echo train length and echo spacing on image contrast and quality

AU - Sze, G.

AU - Kawamura, Y.

AU - Negishi, C.

AU - Constable, R. T.

AU - Merriam, M.

AU - Oshio, Koichi

AU - Jolesz, F.

PY - 1993

Y1 - 1993

N2 - PURPOSE: To examine the interaction of echo train length and interecho spacing and their effects on image quality and contrast in fast spin-echo sequences of the cervical spine. METHODS: Forty-three patients with suspected cervical disk disease were prospectively evaluated with fast spin-echo with varying echo train lengths and interecho spacing. A flow phantom was used to confirm findings related to cerebrospinal fluid pulsation. Parameters were manipulated to adjust contrast, signal-to-noise ratio, the effects of artifacts, and the speed of acquisition. RESULTS: In general, increasing echo train length increased homogeneity and high intensity of cerebrospinal fluid signal and reduced acquisition time; however, it decreased the signal-to- noise ratio of cerebrospinal fluid and cord and increased blurring, and, to a lesser extent, edge enhancement, and 'truncation-type' artifact. Increasing interecho space permitted the use of longer echo times but minimally decreased contrast and signal-to-noise ratio of cord and cerebrospinal fluid. In addition, increasing echo spacing increased blurring, edge enhancement, truncation-type, magnetic susceptibility, and motion artifacts. CONCLUSIONS: For cervical spine imaging, a long echo train length and short echo spacing partially compensate for cerebrospinal fluid flow and produce the best myelographic effect but must be modulated by other constraints, such as artifact production or technical capabilities.

AB - PURPOSE: To examine the interaction of echo train length and interecho spacing and their effects on image quality and contrast in fast spin-echo sequences of the cervical spine. METHODS: Forty-three patients with suspected cervical disk disease were prospectively evaluated with fast spin-echo with varying echo train lengths and interecho spacing. A flow phantom was used to confirm findings related to cerebrospinal fluid pulsation. Parameters were manipulated to adjust contrast, signal-to-noise ratio, the effects of artifacts, and the speed of acquisition. RESULTS: In general, increasing echo train length increased homogeneity and high intensity of cerebrospinal fluid signal and reduced acquisition time; however, it decreased the signal-to- noise ratio of cerebrospinal fluid and cord and increased blurring, and, to a lesser extent, edge enhancement, and 'truncation-type' artifact. Increasing interecho space permitted the use of longer echo times but minimally decreased contrast and signal-to-noise ratio of cord and cerebrospinal fluid. In addition, increasing echo spacing increased blurring, edge enhancement, truncation-type, magnetic susceptibility, and motion artifacts. CONCLUSIONS: For cervical spine imaging, a long echo train length and short echo spacing partially compensate for cerebrospinal fluid flow and produce the best myelographic effect but must be modulated by other constraints, such as artifact production or technical capabilities.

UR - http://www.scopus.com/inward/record.url?scp=0027324189&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0027324189&partnerID=8YFLogxK

M3 - Article

C2 - 8237705

AN - SCOPUS:0027324189

VL - 14

SP - 1203

EP - 1213

JO - American Journal of Neuroradiology

JF - American Journal of Neuroradiology

SN - 0195-6108

IS - 5

ER -