Feasibility of mitral valve repair using the loop technique

Mikihiko Kudo, Ryohei Yozu, Kiyokazu Kokaji, Shirou Iwanaga

Research output: Contribution to journalArticle

17 Citations (Scopus)

Abstract

Purpose: The most difficult aspect of chordal replacement in a mitral valve repair using expanded polytetrafluoroethylene (ePTFE) sutures, is determining the appropriate length of artificial chorda and ligation of the ePTFE sutures without the knot sliding. Patients and Methods: We adopted a loop technique reported by Mohr et al. in 12 consecutive cases from October 2005. Nine cases were comparative broad-range prolapses of the posterior leaflet, 2 cases were anterior and the posterior leaflet and 1 case was vegetation of the anterior leaflet. Chordal replacement was done by 4 loops in 11 cases and by 8 loops in 1 case. Results: Postoperative echocardiography showed more physiological movement of the posterior leaflet than by the resection suture method. When comparing of the peak pressure gradient across the mitral valve on echocardiography between the loop technique group and the nonloop technique group, the gradient in the loop technique group (n=11) was 1.8±0.7 mmHg and in the non-loop technique group (n=18) was 3.2±1.0 mm Hg. There was a significant statistical difference between 2 groups. The loop technique also seemed to be superior procedure hemodynamically. Conclusion: This technique may be useful through both port-access minimally invasive cardiac surgery (MICS) and a conventional approach to the mitral valve, and simplifying chordal replacement. We report on the feasibility of the loop technique based on our experience.

Original languageEnglish
Pages (from-to)21-26
Number of pages6
JournalAnnals of Thoracic and Cardiovascular Surgery
Volume13
Issue number1
Publication statusPublished - 2007 Feb

Fingerprint

Mitral Valve
Sutures
Polytetrafluoroethylene
Echocardiography
Minimally Invasive Surgical Procedures
Prolapse
Thoracic Surgery
Ligation
Pressure

Keywords

  • Artificial chordae
  • Expanded polytetrafluoroethylene
  • Loop technique
  • Mitral valve repair
  • Port-access minimally invasive cardiac surgery

ASJC Scopus subject areas

  • Surgery
  • Cardiology and Cardiovascular Medicine
  • Pulmonary and Respiratory Medicine
  • Gastroenterology
  • Medicine(all)

Cite this

Kudo, M., Yozu, R., Kokaji, K., & Iwanaga, S. (2007). Feasibility of mitral valve repair using the loop technique. Annals of Thoracic and Cardiovascular Surgery, 13(1), 21-26.

Feasibility of mitral valve repair using the loop technique. / Kudo, Mikihiko; Yozu, Ryohei; Kokaji, Kiyokazu; Iwanaga, Shirou.

In: Annals of Thoracic and Cardiovascular Surgery, Vol. 13, No. 1, 02.2007, p. 21-26.

Research output: Contribution to journalArticle

Kudo, M, Yozu, R, Kokaji, K & Iwanaga, S 2007, 'Feasibility of mitral valve repair using the loop technique', Annals of Thoracic and Cardiovascular Surgery, vol. 13, no. 1, pp. 21-26.
Kudo, Mikihiko ; Yozu, Ryohei ; Kokaji, Kiyokazu ; Iwanaga, Shirou. / Feasibility of mitral valve repair using the loop technique. In: Annals of Thoracic and Cardiovascular Surgery. 2007 ; Vol. 13, No. 1. pp. 21-26.
@article{edf1f7e95de64b4b8bb24cd7a9198e34,
title = "Feasibility of mitral valve repair using the loop technique",
abstract = "Purpose: The most difficult aspect of chordal replacement in a mitral valve repair using expanded polytetrafluoroethylene (ePTFE) sutures, is determining the appropriate length of artificial chorda and ligation of the ePTFE sutures without the knot sliding. Patients and Methods: We adopted a loop technique reported by Mohr et al. in 12 consecutive cases from October 2005. Nine cases were comparative broad-range prolapses of the posterior leaflet, 2 cases were anterior and the posterior leaflet and 1 case was vegetation of the anterior leaflet. Chordal replacement was done by 4 loops in 11 cases and by 8 loops in 1 case. Results: Postoperative echocardiography showed more physiological movement of the posterior leaflet than by the resection suture method. When comparing of the peak pressure gradient across the mitral valve on echocardiography between the loop technique group and the nonloop technique group, the gradient in the loop technique group (n=11) was 1.8±0.7 mmHg and in the non-loop technique group (n=18) was 3.2±1.0 mm Hg. There was a significant statistical difference between 2 groups. The loop technique also seemed to be superior procedure hemodynamically. Conclusion: This technique may be useful through both port-access minimally invasive cardiac surgery (MICS) and a conventional approach to the mitral valve, and simplifying chordal replacement. We report on the feasibility of the loop technique based on our experience.",
keywords = "Artificial chordae, Expanded polytetrafluoroethylene, Loop technique, Mitral valve repair, Port-access minimally invasive cardiac surgery",
author = "Mikihiko Kudo and Ryohei Yozu and Kiyokazu Kokaji and Shirou Iwanaga",
year = "2007",
month = "2",
language = "English",
volume = "13",
pages = "21--26",
journal = "Annals of Thoracic and Cardiovascular Surgery",
issn = "1341-1098",
publisher = "Japanese Association for Coronary Artery Surgery",
number = "1",

}

TY - JOUR

T1 - Feasibility of mitral valve repair using the loop technique

AU - Kudo, Mikihiko

AU - Yozu, Ryohei

AU - Kokaji, Kiyokazu

AU - Iwanaga, Shirou

PY - 2007/2

Y1 - 2007/2

N2 - Purpose: The most difficult aspect of chordal replacement in a mitral valve repair using expanded polytetrafluoroethylene (ePTFE) sutures, is determining the appropriate length of artificial chorda and ligation of the ePTFE sutures without the knot sliding. Patients and Methods: We adopted a loop technique reported by Mohr et al. in 12 consecutive cases from October 2005. Nine cases were comparative broad-range prolapses of the posterior leaflet, 2 cases were anterior and the posterior leaflet and 1 case was vegetation of the anterior leaflet. Chordal replacement was done by 4 loops in 11 cases and by 8 loops in 1 case. Results: Postoperative echocardiography showed more physiological movement of the posterior leaflet than by the resection suture method. When comparing of the peak pressure gradient across the mitral valve on echocardiography between the loop technique group and the nonloop technique group, the gradient in the loop technique group (n=11) was 1.8±0.7 mmHg and in the non-loop technique group (n=18) was 3.2±1.0 mm Hg. There was a significant statistical difference between 2 groups. The loop technique also seemed to be superior procedure hemodynamically. Conclusion: This technique may be useful through both port-access minimally invasive cardiac surgery (MICS) and a conventional approach to the mitral valve, and simplifying chordal replacement. We report on the feasibility of the loop technique based on our experience.

AB - Purpose: The most difficult aspect of chordal replacement in a mitral valve repair using expanded polytetrafluoroethylene (ePTFE) sutures, is determining the appropriate length of artificial chorda and ligation of the ePTFE sutures without the knot sliding. Patients and Methods: We adopted a loop technique reported by Mohr et al. in 12 consecutive cases from October 2005. Nine cases were comparative broad-range prolapses of the posterior leaflet, 2 cases were anterior and the posterior leaflet and 1 case was vegetation of the anterior leaflet. Chordal replacement was done by 4 loops in 11 cases and by 8 loops in 1 case. Results: Postoperative echocardiography showed more physiological movement of the posterior leaflet than by the resection suture method. When comparing of the peak pressure gradient across the mitral valve on echocardiography between the loop technique group and the nonloop technique group, the gradient in the loop technique group (n=11) was 1.8±0.7 mmHg and in the non-loop technique group (n=18) was 3.2±1.0 mm Hg. There was a significant statistical difference between 2 groups. The loop technique also seemed to be superior procedure hemodynamically. Conclusion: This technique may be useful through both port-access minimally invasive cardiac surgery (MICS) and a conventional approach to the mitral valve, and simplifying chordal replacement. We report on the feasibility of the loop technique based on our experience.

KW - Artificial chordae

KW - Expanded polytetrafluoroethylene

KW - Loop technique

KW - Mitral valve repair

KW - Port-access minimally invasive cardiac surgery

UR - http://www.scopus.com/inward/record.url?scp=34447314241&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=34447314241&partnerID=8YFLogxK

M3 - Article

C2 - 17392666

AN - SCOPUS:34447314241

VL - 13

SP - 21

EP - 26

JO - Annals of Thoracic and Cardiovascular Surgery

JF - Annals of Thoracic and Cardiovascular Surgery

SN - 1341-1098

IS - 1

ER -