Abstract
A gas fluidic flowmeter of a new shape with a wide measuring range was developed. The major point of this development was to widen the measuring range while keeping pressure loss at a maximum flow rate within 15 mm H SUB 2O. The design incorporates a venturi shaped and a wide feedback loop. The measuring range was increased to approximately 80, and the Reynolds number at minimum flow rate with oscillation was decreased to approximately 21. (A)
Original language | English |
---|---|
Title of host publication | IN |
Subtitle of host publication | FLUID CONTROL AND MEASUREMENT, (TOKYO, JAPAN: SEP. 2-6, 1985), M. HARADA (ED.) |
Publisher | Pergamon Press |
Volume | 2 , Oxford, U.K., Pergamon Press, 1986, p.617-622. (ISBN 0-08-031681-6) |
ISBN (Print) | 0080316816, 9780080316819 |
Publication status | Published - 1986 Jan 1 |
ASJC Scopus subject areas
- Engineering(all)