Functional visual acuity measurement in cataract and intraocular lens implantation

Takefumi Yamaguchi, Kazuno Negishi, Kazuo Tsubota

Research output: Contribution to journalArticle

13 Citations (Scopus)

Abstract

Purpose of review: Recently, functional visual acuity (FVA) measurement has been reported to be an important method of determining 'masked impairment of visual function' and assessing visual acuity in detail. This review discusses a new continuous FVA measurement system for the assessment of visual performance and introduces the application of FVA measurement in cataract and intraocular lens implantation. Recent findings: The FVA was first developed to detect impaired visual function for daily activities in dry eye syndrome. The usefulness of this new methodology has been described in patients with tear instability, undergoing laser-assisted in-situ keratomileusis surgery, with Stevens-Johnson syndrome, Sjögren syndrome and mild cataract opacities. The microstructure of the lenticular opacities is highly variable (nucleus sclerosis and/or posterior capsular cataract and/or cortical opacity) causing a combination of different effects on the incident light rays that can be refracted, reflected, absorbed or scattered. In some cases, patients have a good visual acuity but may complain of disturbances in vision quality. We reported the improvement of FVA after cataract surgery in patients with mild cataracts and visual symptomatology despite a good preoperative and postoperative conventional visual acuity. To detect visual impairment due to cataract, measurement of FVA was useful in the evaluation of vision quality and changes in kinetic vision after phacoemulsification surgery. Summary: FVA measurement is an effective and noninvasive test that reflects the complaints of blurring/glare and postoperative satisfaction in patients with mild cataract.

Original languageEnglish
Pages (from-to)31-36
Number of pages6
JournalCurrent Opinion in Ophthalmology
Volume22
Issue number1
DOIs
Publication statusPublished - 2011 Jan

Fingerprint

Intraocular Lens Implantation
Cataract
Visual Acuity
Vision Disorders
Dry Eye Syndromes
Glare
Laser In Situ Keratomileusis
Stevens-Johnson Syndrome
Phacoemulsification
Sclerosis
Tears
Patient Satisfaction
Light

Keywords

  • Cataract surgery
  • Functional visual acuity
  • Intraocular lens
  • Visual function

ASJC Scopus subject areas

  • Ophthalmology

Cite this

Functional visual acuity measurement in cataract and intraocular lens implantation. / Yamaguchi, Takefumi; Negishi, Kazuno; Tsubota, Kazuo.

In: Current Opinion in Ophthalmology, Vol. 22, No. 1, 01.2011, p. 31-36.

Research output: Contribution to journalArticle

@article{6e74c60fd655415694c8a9995c1dc010,
title = "Functional visual acuity measurement in cataract and intraocular lens implantation",
abstract = "Purpose of review: Recently, functional visual acuity (FVA) measurement has been reported to be an important method of determining 'masked impairment of visual function' and assessing visual acuity in detail. This review discusses a new continuous FVA measurement system for the assessment of visual performance and introduces the application of FVA measurement in cataract and intraocular lens implantation. Recent findings: The FVA was first developed to detect impaired visual function for daily activities in dry eye syndrome. The usefulness of this new methodology has been described in patients with tear instability, undergoing laser-assisted in-situ keratomileusis surgery, with Stevens-Johnson syndrome, Sj{\"o}gren syndrome and mild cataract opacities. The microstructure of the lenticular opacities is highly variable (nucleus sclerosis and/or posterior capsular cataract and/or cortical opacity) causing a combination of different effects on the incident light rays that can be refracted, reflected, absorbed or scattered. In some cases, patients have a good visual acuity but may complain of disturbances in vision quality. We reported the improvement of FVA after cataract surgery in patients with mild cataracts and visual symptomatology despite a good preoperative and postoperative conventional visual acuity. To detect visual impairment due to cataract, measurement of FVA was useful in the evaluation of vision quality and changes in kinetic vision after phacoemulsification surgery. Summary: FVA measurement is an effective and noninvasive test that reflects the complaints of blurring/glare and postoperative satisfaction in patients with mild cataract.",
keywords = "Cataract surgery, Functional visual acuity, Intraocular lens, Visual function",
author = "Takefumi Yamaguchi and Kazuno Negishi and Kazuo Tsubota",
year = "2011",
month = "1",
doi = "10.1097/ICU.0b013e3283414f36",
language = "English",
volume = "22",
pages = "31--36",
journal = "Current Opinion in Ophthalmology",
issn = "1040-8738",
publisher = "Lippincott Williams and Wilkins",
number = "1",

}

TY - JOUR

T1 - Functional visual acuity measurement in cataract and intraocular lens implantation

AU - Yamaguchi, Takefumi

AU - Negishi, Kazuno

AU - Tsubota, Kazuo

PY - 2011/1

Y1 - 2011/1

N2 - Purpose of review: Recently, functional visual acuity (FVA) measurement has been reported to be an important method of determining 'masked impairment of visual function' and assessing visual acuity in detail. This review discusses a new continuous FVA measurement system for the assessment of visual performance and introduces the application of FVA measurement in cataract and intraocular lens implantation. Recent findings: The FVA was first developed to detect impaired visual function for daily activities in dry eye syndrome. The usefulness of this new methodology has been described in patients with tear instability, undergoing laser-assisted in-situ keratomileusis surgery, with Stevens-Johnson syndrome, Sjögren syndrome and mild cataract opacities. The microstructure of the lenticular opacities is highly variable (nucleus sclerosis and/or posterior capsular cataract and/or cortical opacity) causing a combination of different effects on the incident light rays that can be refracted, reflected, absorbed or scattered. In some cases, patients have a good visual acuity but may complain of disturbances in vision quality. We reported the improvement of FVA after cataract surgery in patients with mild cataracts and visual symptomatology despite a good preoperative and postoperative conventional visual acuity. To detect visual impairment due to cataract, measurement of FVA was useful in the evaluation of vision quality and changes in kinetic vision after phacoemulsification surgery. Summary: FVA measurement is an effective and noninvasive test that reflects the complaints of blurring/glare and postoperative satisfaction in patients with mild cataract.

AB - Purpose of review: Recently, functional visual acuity (FVA) measurement has been reported to be an important method of determining 'masked impairment of visual function' and assessing visual acuity in detail. This review discusses a new continuous FVA measurement system for the assessment of visual performance and introduces the application of FVA measurement in cataract and intraocular lens implantation. Recent findings: The FVA was first developed to detect impaired visual function for daily activities in dry eye syndrome. The usefulness of this new methodology has been described in patients with tear instability, undergoing laser-assisted in-situ keratomileusis surgery, with Stevens-Johnson syndrome, Sjögren syndrome and mild cataract opacities. The microstructure of the lenticular opacities is highly variable (nucleus sclerosis and/or posterior capsular cataract and/or cortical opacity) causing a combination of different effects on the incident light rays that can be refracted, reflected, absorbed or scattered. In some cases, patients have a good visual acuity but may complain of disturbances in vision quality. We reported the improvement of FVA after cataract surgery in patients with mild cataracts and visual symptomatology despite a good preoperative and postoperative conventional visual acuity. To detect visual impairment due to cataract, measurement of FVA was useful in the evaluation of vision quality and changes in kinetic vision after phacoemulsification surgery. Summary: FVA measurement is an effective and noninvasive test that reflects the complaints of blurring/glare and postoperative satisfaction in patients with mild cataract.

KW - Cataract surgery

KW - Functional visual acuity

KW - Intraocular lens

KW - Visual function

UR - http://www.scopus.com/inward/record.url?scp=79954993030&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79954993030&partnerID=8YFLogxK

U2 - 10.1097/ICU.0b013e3283414f36

DO - 10.1097/ICU.0b013e3283414f36

M3 - Article

VL - 22

SP - 31

EP - 36

JO - Current Opinion in Ophthalmology

JF - Current Opinion in Ophthalmology

SN - 1040-8738

IS - 1

ER -