This work demonstrates the fabrication of microfluidic paper-based analytical devices (μPADs) suitable for the analysis of sub-microliter sample volumes. The wax-printing approach widely used for the patterning of paper substrates has been adapted to obtain high-resolution microfluidic structures patterned in filter paper. This has been achieved by replacing the hot plate heating method conventionally used to melt printed wax features into paper by simple hot lamination. This patterning technique, in combination with the consideration of device geometry and the influence of cellulose fiber direction in filter paper, led to a model μPAD design with four microfluidic channels that can be filled with as low as 0.5 μL of liquid. Finally, the application to a colorimetric model assay targeting total protein concentrations is shown. Calibration curves for human serum albumin (HSA) were recorded from sub-microliter samples (0.8 μL), with tolerance against �0.1 μL variations in the applied liquid volume.

Original languageEnglish
Article number80
JournalMicromachines
Volume7
Issue number5
DOIs
Publication statusPublished - 2016 Jan 1

Fingerprint

Microfluidics
Waxes
Liquids
Printing
Assays
Cellulose
Calibration
Proteins
Heating
Fabrication
Geometry
Fibers
Substrates

Keywords

  • Colorimetry
  • Inkjet printing
  • Protein assay
  • Wax printing
  • μPAD

ASJC Scopus subject areas

  • Control and Systems Engineering
  • Mechanical Engineering
  • Electrical and Electronic Engineering

Cite this

High-resolution microfluidic paper-based analytical devices for sub-microliter sample analysis. / Tenda, Keisuke; Ota, Riki; Yamada, Kentaro; Henares, Terence G.; Suzuki, Koji; Citterio, Daniel.

In: Micromachines, Vol. 7, No. 5, 80, 01.01.2016.

Research output: Contribution to journalArticle

Tenda, Keisuke ; Ota, Riki ; Yamada, Kentaro ; Henares, Terence G. ; Suzuki, Koji ; Citterio, Daniel. / High-resolution microfluidic paper-based analytical devices for sub-microliter sample analysis. In: Micromachines. 2016 ; Vol. 7, No. 5.
@article{c5e7a20e6b754df9a57ff83003450bc3,
title = "High-resolution microfluidic paper-based analytical devices for sub-microliter sample analysis",
abstract = "This work demonstrates the fabrication of microfluidic paper-based analytical devices (μPADs) suitable for the analysis of sub-microliter sample volumes. The wax-printing approach widely used for the patterning of paper substrates has been adapted to obtain high-resolution microfluidic structures patterned in filter paper. This has been achieved by replacing the hot plate heating method conventionally used to melt printed wax features into paper by simple hot lamination. This patterning technique, in combination with the consideration of device geometry and the influence of cellulose fiber direction in filter paper, led to a model μPAD design with four microfluidic channels that can be filled with as low as 0.5 μL of liquid. Finally, the application to a colorimetric model assay targeting total protein concentrations is shown. Calibration curves for human serum albumin (HSA) were recorded from sub-microliter samples (0.8 μL), with tolerance against {\"i}¿½0.1 μL variations in the applied liquid volume.",
keywords = "Colorimetry, Inkjet printing, Protein assay, Wax printing, μPAD",
author = "Keisuke Tenda and Riki Ota and Kentaro Yamada and Henares, {Terence G.} and Koji Suzuki and Daniel Citterio",
year = "2016",
month = "1",
day = "1",
doi = "10.3390/mi7050080",
language = "English",
volume = "7",
journal = "Micromachines",
issn = "2072-666X",
publisher = "Multidisciplinary Digital Publishing Institute (MDPI)",
number = "5",

}

TY - JOUR

T1 - High-resolution microfluidic paper-based analytical devices for sub-microliter sample analysis

AU - Tenda, Keisuke

AU - Ota, Riki

AU - Yamada, Kentaro

AU - Henares, Terence G.

AU - Suzuki, Koji

AU - Citterio, Daniel

PY - 2016/1/1

Y1 - 2016/1/1

N2 - This work demonstrates the fabrication of microfluidic paper-based analytical devices (μPADs) suitable for the analysis of sub-microliter sample volumes. The wax-printing approach widely used for the patterning of paper substrates has been adapted to obtain high-resolution microfluidic structures patterned in filter paper. This has been achieved by replacing the hot plate heating method conventionally used to melt printed wax features into paper by simple hot lamination. This patterning technique, in combination with the consideration of device geometry and the influence of cellulose fiber direction in filter paper, led to a model μPAD design with four microfluidic channels that can be filled with as low as 0.5 μL of liquid. Finally, the application to a colorimetric model assay targeting total protein concentrations is shown. Calibration curves for human serum albumin (HSA) were recorded from sub-microliter samples (0.8 μL), with tolerance against �0.1 μL variations in the applied liquid volume.

AB - This work demonstrates the fabrication of microfluidic paper-based analytical devices (μPADs) suitable for the analysis of sub-microliter sample volumes. The wax-printing approach widely used for the patterning of paper substrates has been adapted to obtain high-resolution microfluidic structures patterned in filter paper. This has been achieved by replacing the hot plate heating method conventionally used to melt printed wax features into paper by simple hot lamination. This patterning technique, in combination with the consideration of device geometry and the influence of cellulose fiber direction in filter paper, led to a model μPAD design with four microfluidic channels that can be filled with as low as 0.5 μL of liquid. Finally, the application to a colorimetric model assay targeting total protein concentrations is shown. Calibration curves for human serum albumin (HSA) were recorded from sub-microliter samples (0.8 μL), with tolerance against �0.1 μL variations in the applied liquid volume.

KW - Colorimetry

KW - Inkjet printing

KW - Protein assay

KW - Wax printing

KW - μPAD

UR - http://www.scopus.com/inward/record.url?scp=84971247535&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84971247535&partnerID=8YFLogxK

U2 - 10.3390/mi7050080

DO - 10.3390/mi7050080

M3 - Article

VL - 7

JO - Micromachines

JF - Micromachines

SN - 2072-666X

IS - 5

M1 - 80

ER -