Imaging of electrochemical enzyme sensor on gold electrode using surface plasmon resonance

Yuzuru Iwasaki, Tatsuya Tobita, Kazuyoshi Kurihara, Tsutomu Horiuchi, Koji Suzuki, Osamu Niwa

Research output: Contribution to journalArticle

32 Citations (Scopus)

Abstract

Three types of imaging, namely layer structure, electrochemical reaction, and enzyme sensor response, were achieved by applying surface plasmon resonance (SPR) measurement to an electrochemical biosensor. We constructed glucose oxidase based mediator type sensors on a gold electrode by spotting the mediator that contained horseradish peroxidase and spin coating the glucose oxidase film. The layer structure of the sensor was imaged by means of angle scanning SPR measurement. The single sensor spot (about 1 mm in diameter) consisted of about 100×100 pixels and its spatial structure was imaged. The multilayer structure of the enzyme sensor had a complex reflectance-incident angle curve and this required us to choose a suitable incident angle for mapping the redox state. We chose an incident angle that provided the most significant reflection intensity difference by using data obtained from two angle scanning SPR measurements at different electrode potentials. At this incident angle, we controlled the electrochemical states of the spotted mediator in cyclic voltammetry and imaged the degree to which the charged site density changed. Finally, we mapped the enzymatic activity around the mediator spot by the enzymatic reoxidation of pre-reduced mediator in the presence of glucose.

Original languageEnglish
Pages (from-to)783-788
Number of pages6
JournalBiosensors and Bioelectronics
Volume17
Issue number9
DOIs
Publication statusPublished - 2002 Sep

Fingerprint

Enzyme sensors
Electrochemical sensors
Surface Plasmon Resonance
Surface plasmon resonance
Gold
Glucose Oxidase
Electrodes
Glucose oxidase
Imaging techniques
Sensors
Enzymes
Scanning
Metrorrhagia
Spin coating
Biosensing Techniques
Horseradish Peroxidase
Biosensors
Cyclic voltammetry
Oxidation-Reduction
Glucose

Keywords

  • Enzyme
  • Glucose
  • HRP
  • Imaging
  • Os
  • Surface plasmon resonance

ASJC Scopus subject areas

  • Biotechnology
  • Analytical Chemistry
  • Electrochemistry

Cite this

Imaging of electrochemical enzyme sensor on gold electrode using surface plasmon resonance. / Iwasaki, Yuzuru; Tobita, Tatsuya; Kurihara, Kazuyoshi; Horiuchi, Tsutomu; Suzuki, Koji; Niwa, Osamu.

In: Biosensors and Bioelectronics, Vol. 17, No. 9, 09.2002, p. 783-788.

Research output: Contribution to journalArticle

Iwasaki, Y, Tobita, T, Kurihara, K, Horiuchi, T, Suzuki, K & Niwa, O 2002, 'Imaging of electrochemical enzyme sensor on gold electrode using surface plasmon resonance', Biosensors and Bioelectronics, vol. 17, no. 9, pp. 783-788. https://doi.org/10.1016/S0956-5663(02)00054-4
Iwasaki, Yuzuru ; Tobita, Tatsuya ; Kurihara, Kazuyoshi ; Horiuchi, Tsutomu ; Suzuki, Koji ; Niwa, Osamu. / Imaging of electrochemical enzyme sensor on gold electrode using surface plasmon resonance. In: Biosensors and Bioelectronics. 2002 ; Vol. 17, No. 9. pp. 783-788.
@article{cdcfdb64ea854832bed1678091517f50,
title = "Imaging of electrochemical enzyme sensor on gold electrode using surface plasmon resonance",
abstract = "Three types of imaging, namely layer structure, electrochemical reaction, and enzyme sensor response, were achieved by applying surface plasmon resonance (SPR) measurement to an electrochemical biosensor. We constructed glucose oxidase based mediator type sensors on a gold electrode by spotting the mediator that contained horseradish peroxidase and spin coating the glucose oxidase film. The layer structure of the sensor was imaged by means of angle scanning SPR measurement. The single sensor spot (about 1 mm in diameter) consisted of about 100×100 pixels and its spatial structure was imaged. The multilayer structure of the enzyme sensor had a complex reflectance-incident angle curve and this required us to choose a suitable incident angle for mapping the redox state. We chose an incident angle that provided the most significant reflection intensity difference by using data obtained from two angle scanning SPR measurements at different electrode potentials. At this incident angle, we controlled the electrochemical states of the spotted mediator in cyclic voltammetry and imaged the degree to which the charged site density changed. Finally, we mapped the enzymatic activity around the mediator spot by the enzymatic reoxidation of pre-reduced mediator in the presence of glucose.",
keywords = "Enzyme, Glucose, HRP, Imaging, Os, Surface plasmon resonance",
author = "Yuzuru Iwasaki and Tatsuya Tobita and Kazuyoshi Kurihara and Tsutomu Horiuchi and Koji Suzuki and Osamu Niwa",
year = "2002",
month = "9",
doi = "10.1016/S0956-5663(02)00054-4",
language = "English",
volume = "17",
pages = "783--788",
journal = "Biosensors",
issn = "0956-5663",
publisher = "Elsevier Limited",
number = "9",

}

TY - JOUR

T1 - Imaging of electrochemical enzyme sensor on gold electrode using surface plasmon resonance

AU - Iwasaki, Yuzuru

AU - Tobita, Tatsuya

AU - Kurihara, Kazuyoshi

AU - Horiuchi, Tsutomu

AU - Suzuki, Koji

AU - Niwa, Osamu

PY - 2002/9

Y1 - 2002/9

N2 - Three types of imaging, namely layer structure, electrochemical reaction, and enzyme sensor response, were achieved by applying surface plasmon resonance (SPR) measurement to an electrochemical biosensor. We constructed glucose oxidase based mediator type sensors on a gold electrode by spotting the mediator that contained horseradish peroxidase and spin coating the glucose oxidase film. The layer structure of the sensor was imaged by means of angle scanning SPR measurement. The single sensor spot (about 1 mm in diameter) consisted of about 100×100 pixels and its spatial structure was imaged. The multilayer structure of the enzyme sensor had a complex reflectance-incident angle curve and this required us to choose a suitable incident angle for mapping the redox state. We chose an incident angle that provided the most significant reflection intensity difference by using data obtained from two angle scanning SPR measurements at different electrode potentials. At this incident angle, we controlled the electrochemical states of the spotted mediator in cyclic voltammetry and imaged the degree to which the charged site density changed. Finally, we mapped the enzymatic activity around the mediator spot by the enzymatic reoxidation of pre-reduced mediator in the presence of glucose.

AB - Three types of imaging, namely layer structure, electrochemical reaction, and enzyme sensor response, were achieved by applying surface plasmon resonance (SPR) measurement to an electrochemical biosensor. We constructed glucose oxidase based mediator type sensors on a gold electrode by spotting the mediator that contained horseradish peroxidase and spin coating the glucose oxidase film. The layer structure of the sensor was imaged by means of angle scanning SPR measurement. The single sensor spot (about 1 mm in diameter) consisted of about 100×100 pixels and its spatial structure was imaged. The multilayer structure of the enzyme sensor had a complex reflectance-incident angle curve and this required us to choose a suitable incident angle for mapping the redox state. We chose an incident angle that provided the most significant reflection intensity difference by using data obtained from two angle scanning SPR measurements at different electrode potentials. At this incident angle, we controlled the electrochemical states of the spotted mediator in cyclic voltammetry and imaged the degree to which the charged site density changed. Finally, we mapped the enzymatic activity around the mediator spot by the enzymatic reoxidation of pre-reduced mediator in the presence of glucose.

KW - Enzyme

KW - Glucose

KW - HRP

KW - Imaging

KW - Os

KW - Surface plasmon resonance

UR - http://www.scopus.com/inward/record.url?scp=0036717552&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0036717552&partnerID=8YFLogxK

U2 - 10.1016/S0956-5663(02)00054-4

DO - 10.1016/S0956-5663(02)00054-4

M3 - Article

C2 - 12191926

AN - SCOPUS:0036717552

VL - 17

SP - 783

EP - 788

JO - Biosensors

JF - Biosensors

SN - 0956-5663

IS - 9

ER -