Implementation of a plasticized PVC-based cation-selective optode system into a paper-based analytical device for colorimetric sodium detection

Hiroyuki Shibata, Terence G. Henares, Kentaro Yamada, Koji Suzuki, Daniel Citterio

Research output: Contribution to journalArticle

10 Citations (Scopus)

Abstract

On the example of a colorimetric sodium assay, this work demonstrates the implementation of a classical cation-exchange optode relying on an ionophore-doped plasticized PVC membrane into a paper-based analytical device (PAD). An ion-selective optode (ISO) system has been arranged into a vertically-assembled PAD (vPAD) integrating a pH-buffering function. Capillary force-driven sample liquid transportation through the paper matrix enabled pH-adjustment prior to the optical detection of the analyte cation. Functionalized paper layers with inkjet-deposited ISO membranes were combined with whole device lamination to attain a stable ion-exchange equilibrium required for the theoretical behavior of ISOs. Whole device lamination limited rapid evaporation of sample liquid on vPADs to avoid an increase of target concentration. Sigmoidal response curves between 10-5 and 1 M of Na+ at pH 5.0-7.0 have been confirmed on vPADs, following the theory defined by the cation-exchange equilibrium reaction. Finally, the influence of the cellulosic paper substrate matrix acting as a cation-exchanger on the optode response behavior has been evaluated and compared with conventional plastic film optodes.

Original languageEnglish
Pages (from-to)678-686
Number of pages9
JournalAnalyst
Volume143
Issue number3
DOIs
Publication statusPublished - 2018 Feb 7

Fingerprint

Polyvinyl Chloride
Polyvinyl chlorides
Cations
ion exchange
cation
Positive ions
Sodium
lamination
sodium
Equipment and Supplies
Ion exchange
membrane
liquid
matrix
ion
Ion selective membranes
Ions
Ionophores
buffering
Plastic films

ASJC Scopus subject areas

  • Analytical Chemistry
  • Biochemistry
  • Environmental Chemistry
  • Spectroscopy
  • Electrochemistry

Cite this

Implementation of a plasticized PVC-based cation-selective optode system into a paper-based analytical device for colorimetric sodium detection. / Shibata, Hiroyuki; Henares, Terence G.; Yamada, Kentaro; Suzuki, Koji; Citterio, Daniel.

In: Analyst, Vol. 143, No. 3, 07.02.2018, p. 678-686.

Research output: Contribution to journalArticle

Shibata, Hiroyuki ; Henares, Terence G. ; Yamada, Kentaro ; Suzuki, Koji ; Citterio, Daniel. / Implementation of a plasticized PVC-based cation-selective optode system into a paper-based analytical device for colorimetric sodium detection. In: Analyst. 2018 ; Vol. 143, No. 3. pp. 678-686.
@article{8012b71852dc4a6db679c4a34be9f75e,
title = "Implementation of a plasticized PVC-based cation-selective optode system into a paper-based analytical device for colorimetric sodium detection",
abstract = "On the example of a colorimetric sodium assay, this work demonstrates the implementation of a classical cation-exchange optode relying on an ionophore-doped plasticized PVC membrane into a paper-based analytical device (PAD). An ion-selective optode (ISO) system has been arranged into a vertically-assembled PAD (vPAD) integrating a pH-buffering function. Capillary force-driven sample liquid transportation through the paper matrix enabled pH-adjustment prior to the optical detection of the analyte cation. Functionalized paper layers with inkjet-deposited ISO membranes were combined with whole device lamination to attain a stable ion-exchange equilibrium required for the theoretical behavior of ISOs. Whole device lamination limited rapid evaporation of sample liquid on vPADs to avoid an increase of target concentration. Sigmoidal response curves between 10-5 and 1 M of Na+ at pH 5.0-7.0 have been confirmed on vPADs, following the theory defined by the cation-exchange equilibrium reaction. Finally, the influence of the cellulosic paper substrate matrix acting as a cation-exchanger on the optode response behavior has been evaluated and compared with conventional plastic film optodes.",
author = "Hiroyuki Shibata and Henares, {Terence G.} and Kentaro Yamada and Koji Suzuki and Daniel Citterio",
year = "2018",
month = "2",
day = "7",
doi = "10.1039/c7an01952a",
language = "English",
volume = "143",
pages = "678--686",
journal = "The Analyst",
issn = "0003-2654",
publisher = "Royal Society of Chemistry",
number = "3",

}

TY - JOUR

T1 - Implementation of a plasticized PVC-based cation-selective optode system into a paper-based analytical device for colorimetric sodium detection

AU - Shibata, Hiroyuki

AU - Henares, Terence G.

AU - Yamada, Kentaro

AU - Suzuki, Koji

AU - Citterio, Daniel

PY - 2018/2/7

Y1 - 2018/2/7

N2 - On the example of a colorimetric sodium assay, this work demonstrates the implementation of a classical cation-exchange optode relying on an ionophore-doped plasticized PVC membrane into a paper-based analytical device (PAD). An ion-selective optode (ISO) system has been arranged into a vertically-assembled PAD (vPAD) integrating a pH-buffering function. Capillary force-driven sample liquid transportation through the paper matrix enabled pH-adjustment prior to the optical detection of the analyte cation. Functionalized paper layers with inkjet-deposited ISO membranes were combined with whole device lamination to attain a stable ion-exchange equilibrium required for the theoretical behavior of ISOs. Whole device lamination limited rapid evaporation of sample liquid on vPADs to avoid an increase of target concentration. Sigmoidal response curves between 10-5 and 1 M of Na+ at pH 5.0-7.0 have been confirmed on vPADs, following the theory defined by the cation-exchange equilibrium reaction. Finally, the influence of the cellulosic paper substrate matrix acting as a cation-exchanger on the optode response behavior has been evaluated and compared with conventional plastic film optodes.

AB - On the example of a colorimetric sodium assay, this work demonstrates the implementation of a classical cation-exchange optode relying on an ionophore-doped plasticized PVC membrane into a paper-based analytical device (PAD). An ion-selective optode (ISO) system has been arranged into a vertically-assembled PAD (vPAD) integrating a pH-buffering function. Capillary force-driven sample liquid transportation through the paper matrix enabled pH-adjustment prior to the optical detection of the analyte cation. Functionalized paper layers with inkjet-deposited ISO membranes were combined with whole device lamination to attain a stable ion-exchange equilibrium required for the theoretical behavior of ISOs. Whole device lamination limited rapid evaporation of sample liquid on vPADs to avoid an increase of target concentration. Sigmoidal response curves between 10-5 and 1 M of Na+ at pH 5.0-7.0 have been confirmed on vPADs, following the theory defined by the cation-exchange equilibrium reaction. Finally, the influence of the cellulosic paper substrate matrix acting as a cation-exchanger on the optode response behavior has been evaluated and compared with conventional plastic film optodes.

UR - http://www.scopus.com/inward/record.url?scp=85041313413&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85041313413&partnerID=8YFLogxK

U2 - 10.1039/c7an01952a

DO - 10.1039/c7an01952a

M3 - Article

AN - SCOPUS:85041313413

VL - 143

SP - 678

EP - 686

JO - The Analyst

JF - The Analyst

SN - 0003-2654

IS - 3

ER -