Improved leg tracking considering gait phase and spline-based interpolation during turning motion in walk tests

Ayanori Yorozu, Toshiki Moriguchi, Masaki Takahashi

Research output: Contribution to journalArticle

15 Citations (Scopus)

Abstract

Falling is a common problem in the growing elderly population, and fall-risk assessment systems are needed for community-based fall prevention programs. In particular, the timed up and go test (TUG) is the clinical test most often used to evaluate elderly individual ambulatory ability in many clinical institutions or local communities. This study presents an improved leg tracking method using a laser range sensor (LRS) for a gait measurement system to evaluate the motor function in walk tests, such as the TUG. The system tracks both legs and measures the trajectory of both legs. However, both legs might be close to each other, and one leg might be hidden from the sensor. This is especially the case during the turning motion in the TUG, where the time that a leg is hidden from the LRS is longer than that during straight walking and the moving direction rapidly changes. These situations are likely to lead to false tracking and deteriorate the measurement accuracy of the leg positions. To solve these problems, a novel data association considering gait phase and a Catmull–Rom spline-based interpolation during the occlusion are proposed. From the experimental results with young people, we confirm that the proposed methods can reduce the chances of false tracking. In addition, we verify the measurement accuracy of the leg trajectory compared to a three-dimensional motion analysis system (VICON).

Original languageEnglish
Pages (from-to)22451-22472
Number of pages22
JournalSensors (Switzerland)
Volume15
Issue number9
DOIs
Publication statusPublished - 2015 Sep 2

Fingerprint

gait
splines
Gait
Splines
interpolation
Leg
Interpolation
Sensors
Trajectories
Lasers
sensors
Risk assessment
trajectories
three dimensional motion
walking
risk assessment
occlusion
systems analysis
falling
Accidental Falls

Keywords

  • Data association
  • Gait measurement
  • Kalman filter
  • Laser range sensor
  • Spline-based interpolation
  • Timed up and go

ASJC Scopus subject areas

  • Electrical and Electronic Engineering
  • Atomic and Molecular Physics, and Optics
  • Analytical Chemistry
  • Biochemistry

Cite this

Improved leg tracking considering gait phase and spline-based interpolation during turning motion in walk tests. / Yorozu, Ayanori; Moriguchi, Toshiki; Takahashi, Masaki.

In: Sensors (Switzerland), Vol. 15, No. 9, 02.09.2015, p. 22451-22472.

Research output: Contribution to journalArticle

@article{c7709e904b7a4c68b1ac46f44fd275c1,
title = "Improved leg tracking considering gait phase and spline-based interpolation during turning motion in walk tests",
abstract = "Falling is a common problem in the growing elderly population, and fall-risk assessment systems are needed for community-based fall prevention programs. In particular, the timed up and go test (TUG) is the clinical test most often used to evaluate elderly individual ambulatory ability in many clinical institutions or local communities. This study presents an improved leg tracking method using a laser range sensor (LRS) for a gait measurement system to evaluate the motor function in walk tests, such as the TUG. The system tracks both legs and measures the trajectory of both legs. However, both legs might be close to each other, and one leg might be hidden from the sensor. This is especially the case during the turning motion in the TUG, where the time that a leg is hidden from the LRS is longer than that during straight walking and the moving direction rapidly changes. These situations are likely to lead to false tracking and deteriorate the measurement accuracy of the leg positions. To solve these problems, a novel data association considering gait phase and a Catmull–Rom spline-based interpolation during the occlusion are proposed. From the experimental results with young people, we confirm that the proposed methods can reduce the chances of false tracking. In addition, we verify the measurement accuracy of the leg trajectory compared to a three-dimensional motion analysis system (VICON).",
keywords = "Data association, Gait measurement, Kalman filter, Laser range sensor, Spline-based interpolation, Timed up and go",
author = "Ayanori Yorozu and Toshiki Moriguchi and Masaki Takahashi",
year = "2015",
month = "9",
day = "2",
doi = "10.3390/s150922451",
language = "English",
volume = "15",
pages = "22451--22472",
journal = "Sensors (Switzerland)",
issn = "1424-8220",
publisher = "Multidisciplinary Digital Publishing Institute (MDPI)",
number = "9",

}

TY - JOUR

T1 - Improved leg tracking considering gait phase and spline-based interpolation during turning motion in walk tests

AU - Yorozu, Ayanori

AU - Moriguchi, Toshiki

AU - Takahashi, Masaki

PY - 2015/9/2

Y1 - 2015/9/2

N2 - Falling is a common problem in the growing elderly population, and fall-risk assessment systems are needed for community-based fall prevention programs. In particular, the timed up and go test (TUG) is the clinical test most often used to evaluate elderly individual ambulatory ability in many clinical institutions or local communities. This study presents an improved leg tracking method using a laser range sensor (LRS) for a gait measurement system to evaluate the motor function in walk tests, such as the TUG. The system tracks both legs and measures the trajectory of both legs. However, both legs might be close to each other, and one leg might be hidden from the sensor. This is especially the case during the turning motion in the TUG, where the time that a leg is hidden from the LRS is longer than that during straight walking and the moving direction rapidly changes. These situations are likely to lead to false tracking and deteriorate the measurement accuracy of the leg positions. To solve these problems, a novel data association considering gait phase and a Catmull–Rom spline-based interpolation during the occlusion are proposed. From the experimental results with young people, we confirm that the proposed methods can reduce the chances of false tracking. In addition, we verify the measurement accuracy of the leg trajectory compared to a three-dimensional motion analysis system (VICON).

AB - Falling is a common problem in the growing elderly population, and fall-risk assessment systems are needed for community-based fall prevention programs. In particular, the timed up and go test (TUG) is the clinical test most often used to evaluate elderly individual ambulatory ability in many clinical institutions or local communities. This study presents an improved leg tracking method using a laser range sensor (LRS) for a gait measurement system to evaluate the motor function in walk tests, such as the TUG. The system tracks both legs and measures the trajectory of both legs. However, both legs might be close to each other, and one leg might be hidden from the sensor. This is especially the case during the turning motion in the TUG, where the time that a leg is hidden from the LRS is longer than that during straight walking and the moving direction rapidly changes. These situations are likely to lead to false tracking and deteriorate the measurement accuracy of the leg positions. To solve these problems, a novel data association considering gait phase and a Catmull–Rom spline-based interpolation during the occlusion are proposed. From the experimental results with young people, we confirm that the proposed methods can reduce the chances of false tracking. In addition, we verify the measurement accuracy of the leg trajectory compared to a three-dimensional motion analysis system (VICON).

KW - Data association

KW - Gait measurement

KW - Kalman filter

KW - Laser range sensor

KW - Spline-based interpolation

KW - Timed up and go

UR - http://www.scopus.com/inward/record.url?scp=84940987260&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84940987260&partnerID=8YFLogxK

U2 - 10.3390/s150922451

DO - 10.3390/s150922451

M3 - Article

VL - 15

SP - 22451

EP - 22472

JO - Sensors (Switzerland)

JF - Sensors (Switzerland)

SN - 1424-8220

IS - 9

ER -