Improved method of the MALDI-TOF analysis of DNA with nanodot sample target plate

Aki Honda, Hideki Sonobe, Akiko Ogata, Koji Suzuki

Research output: Contribution to journalArticle

8 Citations (Scopus)

Abstract

We report a new sample target plate for MALDI-TOF mass spectrometry made of SiO2 with 30 nm Pt dots for which a highly reproducible and improved DNA analysis was achieved.

Original languageEnglish
Pages (from-to)5340-5342
Number of pages3
JournalChemical Communications
Issue number42
DOIs
Publication statusPublished - 2005 Nov 14

Fingerprint

Mass spectrometry
DNA

ASJC Scopus subject areas

  • Chemistry(all)

Cite this

Improved method of the MALDI-TOF analysis of DNA with nanodot sample target plate. / Honda, Aki; Sonobe, Hideki; Ogata, Akiko; Suzuki, Koji.

In: Chemical Communications, No. 42, 14.11.2005, p. 5340-5342.

Research output: Contribution to journalArticle

Honda, Aki ; Sonobe, Hideki ; Ogata, Akiko ; Suzuki, Koji. / Improved method of the MALDI-TOF analysis of DNA with nanodot sample target plate. In: Chemical Communications. 2005 ; No. 42. pp. 5340-5342.
@article{23266ae65a794755803e771b04a69376,
title = "Improved method of the MALDI-TOF analysis of DNA with nanodot sample target plate",
abstract = "We report a new sample target plate for MALDI-TOF mass spectrometry made of SiO2 with 30 nm Pt dots for which a highly reproducible and improved DNA analysis was achieved.",
author = "Aki Honda and Hideki Sonobe and Akiko Ogata and Koji Suzuki",
year = "2005",
month = "11",
day = "14",
doi = "10.1039/b507065a",
language = "English",
pages = "5340--5342",
journal = "Chemical Communications",
issn = "1359-7345",
publisher = "Royal Society of Chemistry",
number = "42",

}

TY - JOUR

T1 - Improved method of the MALDI-TOF analysis of DNA with nanodot sample target plate

AU - Honda, Aki

AU - Sonobe, Hideki

AU - Ogata, Akiko

AU - Suzuki, Koji

PY - 2005/11/14

Y1 - 2005/11/14

N2 - We report a new sample target plate for MALDI-TOF mass spectrometry made of SiO2 with 30 nm Pt dots for which a highly reproducible and improved DNA analysis was achieved.

AB - We report a new sample target plate for MALDI-TOF mass spectrometry made of SiO2 with 30 nm Pt dots for which a highly reproducible and improved DNA analysis was achieved.

UR - http://www.scopus.com/inward/record.url?scp=27944486457&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=27944486457&partnerID=8YFLogxK

U2 - 10.1039/b507065a

DO - 10.1039/b507065a

M3 - Article

C2 - 16244748

AN - SCOPUS:27944486457

SP - 5340

EP - 5342

JO - Chemical Communications

JF - Chemical Communications

SN - 1359-7345

IS - 42

ER -