Abstract
Flow Accelerated Corrosion (FAC) occurring during in-service conditions results in localized wall-thinning in the feeder pipes of CANDU. The wall-thinning of the feeder pipes is the main degradation mechanisms affecting the integrity of piping systems. In this paper, we assess the integrity of wall-thinned feeder pipes by limit load analysis. The limit loads for wall-thinning feeder pipes subjected to in-plane bending and internal pressure were determined on the basis of finte element limit analyses. The limit loads are determined from the results of limit analyses of elasticperfectly-plastic materials using the large geometry change. Closed-form approximations of limit load solutions for wall-thinning feeder pipes subjected to in-plane bending and pressure are proposed.
Original language | English |
---|---|
Pages (from-to) | 1675-1680 |
Number of pages | 6 |
Journal | Transactions of the Korean Society of Mechanical Engineers, A |
Volume | 34 |
Issue number | 11 |
DOIs | |
Publication status | Published - 2010 Nov |
Externally published | Yes |
Keywords
- Bending
- CANDU
- Circular wall-thinning
- Feeder pipe
- Internal pressure
- Limit load
ASJC Scopus subject areas
- Mechanical Engineering