Measurements of size and velocity of particle in two-phase flow by a three beam LDA system.

Koichi Hishida, M. Maeda, J. Imaru, K. Hironaga, H. Kano

Research output: Contribution to journalArticle

Abstract

A three beam LDA optical system was developed to improve a particle sizing for measuring range up to approximately 400 MUm. The optical system makes a measuring volume with a larger beam and cross beams of smaller diameter, and they are linearly polarized in the orthogonal direction to each. Particle sizes are measured by light scattering intensity from the larger beam and particle velocities are given by Doppler signals from the cross region of two beams with a smaller volume. The experiment of calibration for particle sizing confirms that the measuring range for particle sizing is improved for a larger particle size. The measurement of particle size in free falling spherical glass particles by the three beam LDA system is in good agreement with that by microscopic measurements. (from authors' abstract)

Original languageEnglish
Journal[No source information available]
Issue number(Lisbon, Portugal: Jul. 5-7, 1982)
Publication statusPublished - 1982 Jan 1
Externally publishedYes

Fingerprint

Two phase flow
Particle size
Optical systems
Light scattering
Calibration
Glass
Experiments

ASJC Scopus subject areas

  • Engineering(all)

Cite this

Hishida, K., Maeda, M., Imaru, J., Hironaga, K., & Kano, H. (1982). Measurements of size and velocity of particle in two-phase flow by a three beam LDA system. [No source information available], ((Lisbon, Portugal: Jul. 5-7, 1982)).

Measurements of size and velocity of particle in two-phase flow by a three beam LDA system. / Hishida, Koichi; Maeda, M.; Imaru, J.; Hironaga, K.; Kano, H.

In: [No source information available], No. (Lisbon, Portugal: Jul. 5-7, 1982), 01.01.1982.

Research output: Contribution to journalArticle

Hishida, K, Maeda, M, Imaru, J, Hironaga, K & Kano, H 1982, 'Measurements of size and velocity of particle in two-phase flow by a three beam LDA system.', [No source information available], no. (Lisbon, Portugal: Jul. 5-7, 1982).
Hishida K, Maeda M, Imaru J, Hironaga K, Kano H. Measurements of size and velocity of particle in two-phase flow by a three beam LDA system. [No source information available]. 1982 Jan 1;((Lisbon, Portugal: Jul. 5-7, 1982)).
Hishida, Koichi ; Maeda, M. ; Imaru, J. ; Hironaga, K. ; Kano, H. / Measurements of size and velocity of particle in two-phase flow by a three beam LDA system. In: [No source information available]. 1982 ; No. (Lisbon, Portugal: Jul. 5-7, 1982).
@article{de3f283c8a064af792d861cc19dfabfb,
title = "Measurements of size and velocity of particle in two-phase flow by a three beam LDA system.",
abstract = "A three beam LDA optical system was developed to improve a particle sizing for measuring range up to approximately 400 MUm. The optical system makes a measuring volume with a larger beam and cross beams of smaller diameter, and they are linearly polarized in the orthogonal direction to each. Particle sizes are measured by light scattering intensity from the larger beam and particle velocities are given by Doppler signals from the cross region of two beams with a smaller volume. The experiment of calibration for particle sizing confirms that the measuring range for particle sizing is improved for a larger particle size. The measurement of particle size in free falling spherical glass particles by the three beam LDA system is in good agreement with that by microscopic measurements. (from authors' abstract)",
author = "Koichi Hishida and M. Maeda and J. Imaru and K. Hironaga and H. Kano",
year = "1982",
month = "1",
day = "1",
language = "English",
journal = "[No source information available]",
number = "(Lisbon, Portugal: Jul. 5-7, 1982)",

}

TY - JOUR

T1 - Measurements of size and velocity of particle in two-phase flow by a three beam LDA system.

AU - Hishida, Koichi

AU - Maeda, M.

AU - Imaru, J.

AU - Hironaga, K.

AU - Kano, H.

PY - 1982/1/1

Y1 - 1982/1/1

N2 - A three beam LDA optical system was developed to improve a particle sizing for measuring range up to approximately 400 MUm. The optical system makes a measuring volume with a larger beam and cross beams of smaller diameter, and they are linearly polarized in the orthogonal direction to each. Particle sizes are measured by light scattering intensity from the larger beam and particle velocities are given by Doppler signals from the cross region of two beams with a smaller volume. The experiment of calibration for particle sizing confirms that the measuring range for particle sizing is improved for a larger particle size. The measurement of particle size in free falling spherical glass particles by the three beam LDA system is in good agreement with that by microscopic measurements. (from authors' abstract)

AB - A three beam LDA optical system was developed to improve a particle sizing for measuring range up to approximately 400 MUm. The optical system makes a measuring volume with a larger beam and cross beams of smaller diameter, and they are linearly polarized in the orthogonal direction to each. Particle sizes are measured by light scattering intensity from the larger beam and particle velocities are given by Doppler signals from the cross region of two beams with a smaller volume. The experiment of calibration for particle sizing confirms that the measuring range for particle sizing is improved for a larger particle size. The measurement of particle size in free falling spherical glass particles by the three beam LDA system is in good agreement with that by microscopic measurements. (from authors' abstract)

UR - http://www.scopus.com/inward/record.url?scp=85040282270&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85040282270&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:85040282270

JO - [No source information available]

JF - [No source information available]

IS - (Lisbon, Portugal: Jul. 5-7, 1982)

ER -