Modified optical coefficient measurement system for bulk tissue using an optical fiber insertion with varying field of view and depth at the fiber tip

Haruna Nakazawa, Marika Doi, Emiyu Ogawa, Tsunenori Arai

Research output: Contribution to journalArticle

Abstract

To measure the few millimeter–scale macroscopic optical properties of biological tissue, including the scattering coefficient, while avoiding the instability that originates from sample slicing preparation processes, we performed propagated light intensity measurements through an optical fiber that punctures the bulk tissue while varying the fiber tip depth and the field of view (FOV) at the tip; the results were analyzed using the inverse Monte Carlo method. We realized FOV changes at the fiber tip in the bulk tissue using a variable aperture that was located outside the bulk tissue through a short high-numerical aperture (high-NA) multi-mode fiber with a quasi-straight shape. Using a homogeneous optical model solution, we verified the principle and operation of the constructed experimental system. A 200-μm-core-diameter silica fiber with NA of 0.5 and length of 1 m installed in a 21G needle was used. The detection fiber’s shape was maintained over a radius of curvature of 30 cm. The dependences of the detected light intensity on the FOV and the depth showed better than 1.4% accuracy versus calculated dependences based on the measured optical properties of the solution. Adaptation of the method for use with complex structured biological tissue, particularly in the presence of a thick fascia, was not completely resolved. However, we believe that our specific fiber puncture–based measurement method for use in bulk tissue based on variation of the FOV with inverse Monte Carlo method-based analysis will be useful in obtaining optical coefficients while avoiding sample preparation–related instabilities.

Original languageEnglish
JournalLasers in Medical Science
DOIs
Publication statusPublished - 2019 Jan 1

Fingerprint

Optical Fibers
Monte Carlo Method
Light
Fascia
Punctures
Silicon Dioxide
Needles

Keywords

  • Bulk tissue
  • Field of view
  • Inverse Monte Carlo method
  • Optical coefficient measurement
  • Ray tracing simulation

ASJC Scopus subject areas

  • Surgery
  • Dermatology

Cite this

Modified optical coefficient measurement system for bulk tissue using an optical fiber insertion with varying field of view and depth at the fiber tip. / Nakazawa, Haruna; Doi, Marika; Ogawa, Emiyu; Arai, Tsunenori.

In: Lasers in Medical Science, 01.01.2019.

Research output: Contribution to journalArticle

@article{36e8512820c4456e858747de684c5fe1,
title = "Modified optical coefficient measurement system for bulk tissue using an optical fiber insertion with varying field of view and depth at the fiber tip",
abstract = "To measure the few millimeter–scale macroscopic optical properties of biological tissue, including the scattering coefficient, while avoiding the instability that originates from sample slicing preparation processes, we performed propagated light intensity measurements through an optical fiber that punctures the bulk tissue while varying the fiber tip depth and the field of view (FOV) at the tip; the results were analyzed using the inverse Monte Carlo method. We realized FOV changes at the fiber tip in the bulk tissue using a variable aperture that was located outside the bulk tissue through a short high-numerical aperture (high-NA) multi-mode fiber with a quasi-straight shape. Using a homogeneous optical model solution, we verified the principle and operation of the constructed experimental system. A 200-μm-core-diameter silica fiber with NA of 0.5 and length of 1 m installed in a 21G needle was used. The detection fiber’s shape was maintained over a radius of curvature of 30 cm. The dependences of the detected light intensity on the FOV and the depth showed better than 1.4{\%} accuracy versus calculated dependences based on the measured optical properties of the solution. Adaptation of the method for use with complex structured biological tissue, particularly in the presence of a thick fascia, was not completely resolved. However, we believe that our specific fiber puncture–based measurement method for use in bulk tissue based on variation of the FOV with inverse Monte Carlo method-based analysis will be useful in obtaining optical coefficients while avoiding sample preparation–related instabilities.",
keywords = "Bulk tissue, Field of view, Inverse Monte Carlo method, Optical coefficient measurement, Ray tracing simulation",
author = "Haruna Nakazawa and Marika Doi and Emiyu Ogawa and Tsunenori Arai",
year = "2019",
month = "1",
day = "1",
doi = "10.1007/s10103-019-02756-x",
language = "English",
journal = "Lasers in Medical Science",
issn = "0268-8921",
publisher = "Springer London",

}

TY - JOUR

T1 - Modified optical coefficient measurement system for bulk tissue using an optical fiber insertion with varying field of view and depth at the fiber tip

AU - Nakazawa, Haruna

AU - Doi, Marika

AU - Ogawa, Emiyu

AU - Arai, Tsunenori

PY - 2019/1/1

Y1 - 2019/1/1

N2 - To measure the few millimeter–scale macroscopic optical properties of biological tissue, including the scattering coefficient, while avoiding the instability that originates from sample slicing preparation processes, we performed propagated light intensity measurements through an optical fiber that punctures the bulk tissue while varying the fiber tip depth and the field of view (FOV) at the tip; the results were analyzed using the inverse Monte Carlo method. We realized FOV changes at the fiber tip in the bulk tissue using a variable aperture that was located outside the bulk tissue through a short high-numerical aperture (high-NA) multi-mode fiber with a quasi-straight shape. Using a homogeneous optical model solution, we verified the principle and operation of the constructed experimental system. A 200-μm-core-diameter silica fiber with NA of 0.5 and length of 1 m installed in a 21G needle was used. The detection fiber’s shape was maintained over a radius of curvature of 30 cm. The dependences of the detected light intensity on the FOV and the depth showed better than 1.4% accuracy versus calculated dependences based on the measured optical properties of the solution. Adaptation of the method for use with complex structured biological tissue, particularly in the presence of a thick fascia, was not completely resolved. However, we believe that our specific fiber puncture–based measurement method for use in bulk tissue based on variation of the FOV with inverse Monte Carlo method-based analysis will be useful in obtaining optical coefficients while avoiding sample preparation–related instabilities.

AB - To measure the few millimeter–scale macroscopic optical properties of biological tissue, including the scattering coefficient, while avoiding the instability that originates from sample slicing preparation processes, we performed propagated light intensity measurements through an optical fiber that punctures the bulk tissue while varying the fiber tip depth and the field of view (FOV) at the tip; the results were analyzed using the inverse Monte Carlo method. We realized FOV changes at the fiber tip in the bulk tissue using a variable aperture that was located outside the bulk tissue through a short high-numerical aperture (high-NA) multi-mode fiber with a quasi-straight shape. Using a homogeneous optical model solution, we verified the principle and operation of the constructed experimental system. A 200-μm-core-diameter silica fiber with NA of 0.5 and length of 1 m installed in a 21G needle was used. The detection fiber’s shape was maintained over a radius of curvature of 30 cm. The dependences of the detected light intensity on the FOV and the depth showed better than 1.4% accuracy versus calculated dependences based on the measured optical properties of the solution. Adaptation of the method for use with complex structured biological tissue, particularly in the presence of a thick fascia, was not completely resolved. However, we believe that our specific fiber puncture–based measurement method for use in bulk tissue based on variation of the FOV with inverse Monte Carlo method-based analysis will be useful in obtaining optical coefficients while avoiding sample preparation–related instabilities.

KW - Bulk tissue

KW - Field of view

KW - Inverse Monte Carlo method

KW - Optical coefficient measurement

KW - Ray tracing simulation

UR - http://www.scopus.com/inward/record.url?scp=85062952253&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85062952253&partnerID=8YFLogxK

U2 - 10.1007/s10103-019-02756-x

DO - 10.1007/s10103-019-02756-x

M3 - Article

JO - Lasers in Medical Science

JF - Lasers in Medical Science

SN - 0268-8921

ER -