TY - JOUR
T1 - Modified percutaneous coronary intervention-derived risk models (PARIS and CREDO-Kyoto integer scoring systems) applied to Japanese transcatheter aortic valve replacement patients
AU - Ohya, Masanobu
AU - Kohsaka, Shun
AU - Kumamaru, Hiraku
AU - Ikuta, Akihiro
AU - Nakano, Jota
AU - Shimamoto, Takeshi
AU - Watanabe, Yusuke
AU - Shimamura, Kazuo
AU - Maeda, Koichi
AU - Komiya, Tatsuhiko
AU - Fuku, Yasushi
AU - Kadota, Kazushige
N1 - Publisher Copyright:
© 2023 BMJ Publishing Group. All rights reserved.
PY - 2023/1/19
Y1 - 2023/1/19
N2 - Objective Postprocedural ischaemic and bleeding risks after transcatheter aortic valve replacement (TAVR) remain a major concern. Nevertheless, no reliable risk models incorporating both possibilities are currently available. We aimed to assess the accuracy of percutaneous coronary intervention (PCI)-derived models and the performance of a recalibrated model that included variables more applicable to TAVR. Methods This study included 26 869 patients who had been enrolled in a national registry. Ischaemic events were defined as myocardial infarction, stroke, transient ischaemic attack or peripheral embolism at 1 year. Bleeding events were defined as any bleeding based on the Valve Academic Research Consortium-2 consensus document at 1 year. Patterns of Non-adherence to Anti-Platelet Regimen in Stented Patients (PARIS) and Coronary Revascularisation Demonstrating Outcome Study in Kyoto (CREDO-Kyoto) integer scoring systems were tested. The models were recalibrated by applying new variables using the Fine and Gray method. Results The 1-year cumulative incidences for ischaemic and bleeding events were 2.7% and 3.1%. Patients with high PARIS and CREDO-Kyoto risk scores had higher incidences of both ischaemic (3.3% vs 2.4% vs 2.4%, p<0.001 and 2.8% vs 2.0% vs 0.8%, p<0.001) and bleeding events (3.3% vs 2.5% vs 0.8%, p<0.001 and 3.7% vs 3.0% vs 2.4%, p<0.001) when compared with intermediate and low-risk patients. The receiver operating characteristic area under the curves for these models were 0.53, 0.58, 0.56 and 0.55, respectively. After the models were recalibrated to incorporate variables more applicable to TAVR, the performance of ischaemic and bleeding models modestly improved (0.58 and 0.61, respectively). Conclusions The PCI-derived models demonstrated modest accuracy but was inadequate for risk stratification of TAVR patients at 1-year follow-up. Trial registration number 3395.
AB - Objective Postprocedural ischaemic and bleeding risks after transcatheter aortic valve replacement (TAVR) remain a major concern. Nevertheless, no reliable risk models incorporating both possibilities are currently available. We aimed to assess the accuracy of percutaneous coronary intervention (PCI)-derived models and the performance of a recalibrated model that included variables more applicable to TAVR. Methods This study included 26 869 patients who had been enrolled in a national registry. Ischaemic events were defined as myocardial infarction, stroke, transient ischaemic attack or peripheral embolism at 1 year. Bleeding events were defined as any bleeding based on the Valve Academic Research Consortium-2 consensus document at 1 year. Patterns of Non-adherence to Anti-Platelet Regimen in Stented Patients (PARIS) and Coronary Revascularisation Demonstrating Outcome Study in Kyoto (CREDO-Kyoto) integer scoring systems were tested. The models were recalibrated by applying new variables using the Fine and Gray method. Results The 1-year cumulative incidences for ischaemic and bleeding events were 2.7% and 3.1%. Patients with high PARIS and CREDO-Kyoto risk scores had higher incidences of both ischaemic (3.3% vs 2.4% vs 2.4%, p<0.001 and 2.8% vs 2.0% vs 0.8%, p<0.001) and bleeding events (3.3% vs 2.5% vs 0.8%, p<0.001 and 3.7% vs 3.0% vs 2.4%, p<0.001) when compared with intermediate and low-risk patients. The receiver operating characteristic area under the curves for these models were 0.53, 0.58, 0.56 and 0.55, respectively. After the models were recalibrated to incorporate variables more applicable to TAVR, the performance of ischaemic and bleeding models modestly improved (0.58 and 0.61, respectively). Conclusions The PCI-derived models demonstrated modest accuracy but was inadequate for risk stratification of TAVR patients at 1-year follow-up. Trial registration number 3395.
KW - aortic valve stenosis
KW - cardiac catheterization
KW - translational medical research
UR - http://www.scopus.com/inward/record.url?scp=85146934499&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85146934499&partnerID=8YFLogxK
U2 - 10.1136/openhrt-2022-002172
DO - 10.1136/openhrt-2022-002172
M3 - Article
AN - SCOPUS:85146934499
SN - 2053-3624
VL - 10
JO - Open Heart
JF - Open Heart
IS - 1
M1 - A3
ER -