Natural frequencies of brachii muscle at various contraction levels

Saki Okura, Takanori Uchiyama

Research output: Contribution to journalArticle

Abstract

The natural frequencies of the longitudinal and radial directions of the biceps brachii muscle were estimated by measuring evoked torque and muscle oscillation, respectively. The purpose of this study is to reveal the relation between the natural frequencies of longitudinal and radial directions to the biceps brachii muscle. An electrically stimulated evoked torque and mechanically stimulated evoked muscle oscillation were measured with a strain gauge load cell and myotonometer, respectively. The measurement was carried out during a resting state and an isometric contraction. The systems of the evoked torque and the muscle oscillation were identified. The natural frequency of the systems was calculated from the poles of the transfer function. In conclusion, the frequency of evoked torque and muscle oscillation increased as the muscle contraction level increased. It is suggested that the natural frequency of the axial direction might be estimated from the natural frequency of the radial direction of the muscle.

Original languageEnglish
Pages (from-to)532-533
Number of pages2
JournalTransactions of Japanese Society for Medical and Biological Engineering
Volume55
Issue numberProc
DOIs
Publication statusPublished - 2017

Fingerprint

Muscle
Natural frequencies
Torque
Strain gages
Transfer functions
Poles

Keywords

  • Biceps brachii
  • Myotonometer
  • System identification
  • Torque

ASJC Scopus subject areas

  • Biomedical Engineering

Cite this

Natural frequencies of brachii muscle at various contraction levels. / Okura, Saki; Uchiyama, Takanori.

In: Transactions of Japanese Society for Medical and Biological Engineering, Vol. 55, No. Proc, 2017, p. 532-533.

Research output: Contribution to journalArticle

@article{7fcd48671a1142b1891a24e77e6b82d1,
title = "Natural frequencies of brachii muscle at various contraction levels",
abstract = "The natural frequencies of the longitudinal and radial directions of the biceps brachii muscle were estimated by measuring evoked torque and muscle oscillation, respectively. The purpose of this study is to reveal the relation between the natural frequencies of longitudinal and radial directions to the biceps brachii muscle. An electrically stimulated evoked torque and mechanically stimulated evoked muscle oscillation were measured with a strain gauge load cell and myotonometer, respectively. The measurement was carried out during a resting state and an isometric contraction. The systems of the evoked torque and the muscle oscillation were identified. The natural frequency of the systems was calculated from the poles of the transfer function. In conclusion, the frequency of evoked torque and muscle oscillation increased as the muscle contraction level increased. It is suggested that the natural frequency of the axial direction might be estimated from the natural frequency of the radial direction of the muscle.",
keywords = "Biceps brachii, Myotonometer, System identification, Torque",
author = "Saki Okura and Takanori Uchiyama",
year = "2017",
doi = "10.11239/jsmbe.55Annual.532",
language = "English",
volume = "55",
pages = "532--533",
journal = "BME = Bio medical engineering / henshu, Nihon ME Gakkai",
issn = "1347-443X",
publisher = "Nihon M E Gakkai",
number = "Proc",

}

TY - JOUR

T1 - Natural frequencies of brachii muscle at various contraction levels

AU - Okura, Saki

AU - Uchiyama, Takanori

PY - 2017

Y1 - 2017

N2 - The natural frequencies of the longitudinal and radial directions of the biceps brachii muscle were estimated by measuring evoked torque and muscle oscillation, respectively. The purpose of this study is to reveal the relation between the natural frequencies of longitudinal and radial directions to the biceps brachii muscle. An electrically stimulated evoked torque and mechanically stimulated evoked muscle oscillation were measured with a strain gauge load cell and myotonometer, respectively. The measurement was carried out during a resting state and an isometric contraction. The systems of the evoked torque and the muscle oscillation were identified. The natural frequency of the systems was calculated from the poles of the transfer function. In conclusion, the frequency of evoked torque and muscle oscillation increased as the muscle contraction level increased. It is suggested that the natural frequency of the axial direction might be estimated from the natural frequency of the radial direction of the muscle.

AB - The natural frequencies of the longitudinal and radial directions of the biceps brachii muscle were estimated by measuring evoked torque and muscle oscillation, respectively. The purpose of this study is to reveal the relation between the natural frequencies of longitudinal and radial directions to the biceps brachii muscle. An electrically stimulated evoked torque and mechanically stimulated evoked muscle oscillation were measured with a strain gauge load cell and myotonometer, respectively. The measurement was carried out during a resting state and an isometric contraction. The systems of the evoked torque and the muscle oscillation were identified. The natural frequency of the systems was calculated from the poles of the transfer function. In conclusion, the frequency of evoked torque and muscle oscillation increased as the muscle contraction level increased. It is suggested that the natural frequency of the axial direction might be estimated from the natural frequency of the radial direction of the muscle.

KW - Biceps brachii

KW - Myotonometer

KW - System identification

KW - Torque

UR - http://www.scopus.com/inward/record.url?scp=85029857954&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85029857954&partnerID=8YFLogxK

U2 - 10.11239/jsmbe.55Annual.532