New innovative instruments facilitate both direct-vision and endoscopic-assisted mini-mitral valve surgery

Ryohei Yozu, Kazuma Okamoto, Mikihiko Kudo, Hidenori Nonaka, David H. Adams

Research output: Contribution to journalArticle

11 Citations (Scopus)

Abstract

Objective: The efficacy of new, innovative, original instruments, including a left atrial retractor, silicon annuloplasty ring sizer, modified Cosgrove aortic clamp, and reusable clip for fixing knots of polytetrafluoroethylene (Gore-Tex; WL Gore & Associates, Inc, Flagstaff, Ariz) suture, to allow surgical exposure in an ideal operative setting of mini-mitral valve repair surgery was verified. Methods: Since 1998, a great deal of innovation has contributed to establishing mitral valve repair via right minithoracotomy as a routine surgical approach for mitral valve insufficiency in 252 cases. During the last 2 years, a newly launched left atrial retractor system attachable to the minithoracotomy spreader has been used. An additional retractor for the posterior wall of the left atrium was attached to the minithoracotomy spreader. The retractor moves flexibly and can be fixed in any favorable position to realize optimal exposure of the mitral valve. A 5 blade size was available depending on the left atrial size and target legion. By using the smallest size, even papillary muscles were exposed easily and clearly. Furthermore, a flexible silicon ring sizer, which could easily pass thorough a narrow working port without tissue damage, was used for sizing the annuloplasty ring. For the surgical technique, multiple chordal reconstructions by the loop technique with polytetrafluoroethylene (Gore-Tex CV-5 sutures) were applied. A reusable clip for fixing knots made it easy to tie the Gore-Tex suture in the correct position without slipping. Results: No operative mortality occurred. There were 2 conversions to sternotomy for correction of aortic dissection (1) and for coronary artery bypass grafting (1). There were 2 early reoperations for failure of mitral valve repair. The mean aortic crossclamp time was 163.5 ± 41.6 minutes. Annuloplasty with a ring or band was performed in all cases except one. The loop technique was used in 173 cases. Among them, a combination of the loop technique and resection and suture technique was used in 56 cases. Conclusions: Newly innovated mini-mitral valve surgical instruments and techniques facilitate both direct-vision and endoscopic-assisted approaches and accomplish a favorable surgical outcome even in the complex pathology of mitral valve insufficiency.

Original languageEnglish
JournalJournal of Thoracic and Cardiovascular Surgery
Volume143
Issue number4 SUPPL.
DOIs
Publication statusPublished - 2012 Apr

Fingerprint

Mitral Valve
Surgical Instruments
Sutures
Polytetrafluoroethylene
Mitral Valve Insufficiency
Silicon
Suture Techniques
Sternotomy
Papillary Muscles
Heart Atria
Reoperation
Coronary Artery Bypass
Dissection
Pathology
Mortality

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine
  • Surgery
  • Pulmonary and Respiratory Medicine

Cite this

New innovative instruments facilitate both direct-vision and endoscopic-assisted mini-mitral valve surgery. / Yozu, Ryohei; Okamoto, Kazuma; Kudo, Mikihiko; Nonaka, Hidenori; Adams, David H.

In: Journal of Thoracic and Cardiovascular Surgery, Vol. 143, No. 4 SUPPL., 04.2012.

Research output: Contribution to journalArticle

Yozu, Ryohei ; Okamoto, Kazuma ; Kudo, Mikihiko ; Nonaka, Hidenori ; Adams, David H. / New innovative instruments facilitate both direct-vision and endoscopic-assisted mini-mitral valve surgery. In: Journal of Thoracic and Cardiovascular Surgery. 2012 ; Vol. 143, No. 4 SUPPL.
@article{2278119cb09a4c649414b2ddc0e9454f,
title = "New innovative instruments facilitate both direct-vision and endoscopic-assisted mini-mitral valve surgery",
abstract = "Objective: The efficacy of new, innovative, original instruments, including a left atrial retractor, silicon annuloplasty ring sizer, modified Cosgrove aortic clamp, and reusable clip for fixing knots of polytetrafluoroethylene (Gore-Tex; WL Gore & Associates, Inc, Flagstaff, Ariz) suture, to allow surgical exposure in an ideal operative setting of mini-mitral valve repair surgery was verified. Methods: Since 1998, a great deal of innovation has contributed to establishing mitral valve repair via right minithoracotomy as a routine surgical approach for mitral valve insufficiency in 252 cases. During the last 2 years, a newly launched left atrial retractor system attachable to the minithoracotomy spreader has been used. An additional retractor for the posterior wall of the left atrium was attached to the minithoracotomy spreader. The retractor moves flexibly and can be fixed in any favorable position to realize optimal exposure of the mitral valve. A 5 blade size was available depending on the left atrial size and target legion. By using the smallest size, even papillary muscles were exposed easily and clearly. Furthermore, a flexible silicon ring sizer, which could easily pass thorough a narrow working port without tissue damage, was used for sizing the annuloplasty ring. For the surgical technique, multiple chordal reconstructions by the loop technique with polytetrafluoroethylene (Gore-Tex CV-5 sutures) were applied. A reusable clip for fixing knots made it easy to tie the Gore-Tex suture in the correct position without slipping. Results: No operative mortality occurred. There were 2 conversions to sternotomy for correction of aortic dissection (1) and for coronary artery bypass grafting (1). There were 2 early reoperations for failure of mitral valve repair. The mean aortic crossclamp time was 163.5 ± 41.6 minutes. Annuloplasty with a ring or band was performed in all cases except one. The loop technique was used in 173 cases. Among them, a combination of the loop technique and resection and suture technique was used in 56 cases. Conclusions: Newly innovated mini-mitral valve surgical instruments and techniques facilitate both direct-vision and endoscopic-assisted approaches and accomplish a favorable surgical outcome even in the complex pathology of mitral valve insufficiency.",
author = "Ryohei Yozu and Kazuma Okamoto and Mikihiko Kudo and Hidenori Nonaka and Adams, {David H.}",
year = "2012",
month = "4",
doi = "10.1016/j.jtcvs.2011.05.026",
language = "English",
volume = "143",
journal = "Journal of Thoracic and Cardiovascular Surgery",
issn = "0022-5223",
publisher = "Mosby Inc.",
number = "4 SUPPL.",

}

TY - JOUR

T1 - New innovative instruments facilitate both direct-vision and endoscopic-assisted mini-mitral valve surgery

AU - Yozu, Ryohei

AU - Okamoto, Kazuma

AU - Kudo, Mikihiko

AU - Nonaka, Hidenori

AU - Adams, David H.

PY - 2012/4

Y1 - 2012/4

N2 - Objective: The efficacy of new, innovative, original instruments, including a left atrial retractor, silicon annuloplasty ring sizer, modified Cosgrove aortic clamp, and reusable clip for fixing knots of polytetrafluoroethylene (Gore-Tex; WL Gore & Associates, Inc, Flagstaff, Ariz) suture, to allow surgical exposure in an ideal operative setting of mini-mitral valve repair surgery was verified. Methods: Since 1998, a great deal of innovation has contributed to establishing mitral valve repair via right minithoracotomy as a routine surgical approach for mitral valve insufficiency in 252 cases. During the last 2 years, a newly launched left atrial retractor system attachable to the minithoracotomy spreader has been used. An additional retractor for the posterior wall of the left atrium was attached to the minithoracotomy spreader. The retractor moves flexibly and can be fixed in any favorable position to realize optimal exposure of the mitral valve. A 5 blade size was available depending on the left atrial size and target legion. By using the smallest size, even papillary muscles were exposed easily and clearly. Furthermore, a flexible silicon ring sizer, which could easily pass thorough a narrow working port without tissue damage, was used for sizing the annuloplasty ring. For the surgical technique, multiple chordal reconstructions by the loop technique with polytetrafluoroethylene (Gore-Tex CV-5 sutures) were applied. A reusable clip for fixing knots made it easy to tie the Gore-Tex suture in the correct position without slipping. Results: No operative mortality occurred. There were 2 conversions to sternotomy for correction of aortic dissection (1) and for coronary artery bypass grafting (1). There were 2 early reoperations for failure of mitral valve repair. The mean aortic crossclamp time was 163.5 ± 41.6 minutes. Annuloplasty with a ring or band was performed in all cases except one. The loop technique was used in 173 cases. Among them, a combination of the loop technique and resection and suture technique was used in 56 cases. Conclusions: Newly innovated mini-mitral valve surgical instruments and techniques facilitate both direct-vision and endoscopic-assisted approaches and accomplish a favorable surgical outcome even in the complex pathology of mitral valve insufficiency.

AB - Objective: The efficacy of new, innovative, original instruments, including a left atrial retractor, silicon annuloplasty ring sizer, modified Cosgrove aortic clamp, and reusable clip for fixing knots of polytetrafluoroethylene (Gore-Tex; WL Gore & Associates, Inc, Flagstaff, Ariz) suture, to allow surgical exposure in an ideal operative setting of mini-mitral valve repair surgery was verified. Methods: Since 1998, a great deal of innovation has contributed to establishing mitral valve repair via right minithoracotomy as a routine surgical approach for mitral valve insufficiency in 252 cases. During the last 2 years, a newly launched left atrial retractor system attachable to the minithoracotomy spreader has been used. An additional retractor for the posterior wall of the left atrium was attached to the minithoracotomy spreader. The retractor moves flexibly and can be fixed in any favorable position to realize optimal exposure of the mitral valve. A 5 blade size was available depending on the left atrial size and target legion. By using the smallest size, even papillary muscles were exposed easily and clearly. Furthermore, a flexible silicon ring sizer, which could easily pass thorough a narrow working port without tissue damage, was used for sizing the annuloplasty ring. For the surgical technique, multiple chordal reconstructions by the loop technique with polytetrafluoroethylene (Gore-Tex CV-5 sutures) were applied. A reusable clip for fixing knots made it easy to tie the Gore-Tex suture in the correct position without slipping. Results: No operative mortality occurred. There were 2 conversions to sternotomy for correction of aortic dissection (1) and for coronary artery bypass grafting (1). There were 2 early reoperations for failure of mitral valve repair. The mean aortic crossclamp time was 163.5 ± 41.6 minutes. Annuloplasty with a ring or band was performed in all cases except one. The loop technique was used in 173 cases. Among them, a combination of the loop technique and resection and suture technique was used in 56 cases. Conclusions: Newly innovated mini-mitral valve surgical instruments and techniques facilitate both direct-vision and endoscopic-assisted approaches and accomplish a favorable surgical outcome even in the complex pathology of mitral valve insufficiency.

UR - http://www.scopus.com/inward/record.url?scp=84858333091&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84858333091&partnerID=8YFLogxK

U2 - 10.1016/j.jtcvs.2011.05.026

DO - 10.1016/j.jtcvs.2011.05.026

M3 - Article

VL - 143

JO - Journal of Thoracic and Cardiovascular Surgery

JF - Journal of Thoracic and Cardiovascular Surgery

SN - 0022-5223

IS - 4 SUPPL.

ER -