Abstract

A new percutaneous transluminal coronary angioscopic catheter has been developed for visualization of the coronary artery. A specially made balloon, fixed at the catheter tip, and an angulation mechanism made a precise coaxial alignment possible in the coronary lumen. This angioscopic catheter, 1.22 mm in outer diameter, has four channels, one for irrigation in which a 0.36 mm (0.014 in.) angioplasty guide wire can be used. With the use of this angioscope, coronary lumens in 8 dogs, thrombi that were produced with copper coils in the left anterior descending coronary artery in 11 dogs, atherosclerotic coronary arteries in 20 patients during cardiac catheterization and the sequence of transluminal coronary angioplasty in 1 patient were observed. The angioscopic catheter was introduced into the coronary artery by an 8F guide catheter. The steerable guide wire enabled the angioscopic catheter to be accurately and safely inserted into the target lesion in all cases. The inflated balloon and angulation mechanism allowed a curved coronary lumen and atheroma to be seen with a limited volume of irrigation fluid. Visualization was good (complete visualization of the inner lumen) in 46% (10 of 22 lesions), moderate (visualization of >50% of the inner lumen) in 36% (8 of 22 lesions) and poor (visualization of <50% of the inner lumen) in 18% (4 of 22 lesions) in humans. There were no major complications. These preliminary experiences in closed chest cardiac catheterization in dogs and in humans indicate the feasibility of this angioscope. The information yielded by angioscopy may be clinically useful in the study of the pathophysiologic changes in coronary disease that are not detected by coronary arteriography.

Original languageEnglish
Pages (from-to)363-368
Number of pages6
JournalJournal of the American College of Cardiology
Volume13
Issue number2
DOIs
Publication statusPublished - 1989
Externally publishedYes

Fingerprint

Angioscopes
Catheters
Coronary Vessels
Dogs
Cardiac Catheterization
Angioplasty
Angioscopy
Atherosclerotic Plaques
Coronary Disease
Copper
Angiography
Thrombosis
Thorax

ASJC Scopus subject areas

  • Nursing(all)

Cite this

Mizuno, K., Arai, T., Satomura, K., Shibuya, T., Arakawa, K., Okamoto, Y., ... Takeuchi, K. (1989). New percutaneous transluminal coronary angioscope. Journal of the American College of Cardiology, 13(2), 363-368. https://doi.org/10.1016/0735-1097(89)90513-5

New percutaneous transluminal coronary angioscope. / Mizuno, Kyoichi; Arai, Tsunenori; Satomura, Kimio; Shibuya, Toshio; Arakawa, Ko; Okamoto, Yasuhiro; Miyamoto, Akira; Kurita, Akira; Kikuchi, Makoto; Nakamura, Haruo; Utsumi, Atsushi; Takeuchi, Kiyoshi.

In: Journal of the American College of Cardiology, Vol. 13, No. 2, 1989, p. 363-368.

Research output: Contribution to journalArticle

Mizuno, K, Arai, T, Satomura, K, Shibuya, T, Arakawa, K, Okamoto, Y, Miyamoto, A, Kurita, A, Kikuchi, M, Nakamura, H, Utsumi, A & Takeuchi, K 1989, 'New percutaneous transluminal coronary angioscope', Journal of the American College of Cardiology, vol. 13, no. 2, pp. 363-368. https://doi.org/10.1016/0735-1097(89)90513-5
Mizuno K, Arai T, Satomura K, Shibuya T, Arakawa K, Okamoto Y et al. New percutaneous transluminal coronary angioscope. Journal of the American College of Cardiology. 1989;13(2):363-368. https://doi.org/10.1016/0735-1097(89)90513-5
Mizuno, Kyoichi ; Arai, Tsunenori ; Satomura, Kimio ; Shibuya, Toshio ; Arakawa, Ko ; Okamoto, Yasuhiro ; Miyamoto, Akira ; Kurita, Akira ; Kikuchi, Makoto ; Nakamura, Haruo ; Utsumi, Atsushi ; Takeuchi, Kiyoshi. / New percutaneous transluminal coronary angioscope. In: Journal of the American College of Cardiology. 1989 ; Vol. 13, No. 2. pp. 363-368.
@article{6d35bbf2325b45f897febec256f1092a,
title = "New percutaneous transluminal coronary angioscope",
abstract = "A new percutaneous transluminal coronary angioscopic catheter has been developed for visualization of the coronary artery. A specially made balloon, fixed at the catheter tip, and an angulation mechanism made a precise coaxial alignment possible in the coronary lumen. This angioscopic catheter, 1.22 mm in outer diameter, has four channels, one for irrigation in which a 0.36 mm (0.014 in.) angioplasty guide wire can be used. With the use of this angioscope, coronary lumens in 8 dogs, thrombi that were produced with copper coils in the left anterior descending coronary artery in 11 dogs, atherosclerotic coronary arteries in 20 patients during cardiac catheterization and the sequence of transluminal coronary angioplasty in 1 patient were observed. The angioscopic catheter was introduced into the coronary artery by an 8F guide catheter. The steerable guide wire enabled the angioscopic catheter to be accurately and safely inserted into the target lesion in all cases. The inflated balloon and angulation mechanism allowed a curved coronary lumen and atheroma to be seen with a limited volume of irrigation fluid. Visualization was good (complete visualization of the inner lumen) in 46{\%} (10 of 22 lesions), moderate (visualization of >50{\%} of the inner lumen) in 36{\%} (8 of 22 lesions) and poor (visualization of <50{\%} of the inner lumen) in 18{\%} (4 of 22 lesions) in humans. There were no major complications. These preliminary experiences in closed chest cardiac catheterization in dogs and in humans indicate the feasibility of this angioscope. The information yielded by angioscopy may be clinically useful in the study of the pathophysiologic changes in coronary disease that are not detected by coronary arteriography.",
author = "Kyoichi Mizuno and Tsunenori Arai and Kimio Satomura and Toshio Shibuya and Ko Arakawa and Yasuhiro Okamoto and Akira Miyamoto and Akira Kurita and Makoto Kikuchi and Haruo Nakamura and Atsushi Utsumi and Kiyoshi Takeuchi",
year = "1989",
doi = "10.1016/0735-1097(89)90513-5",
language = "English",
volume = "13",
pages = "363--368",
journal = "Journal of the American College of Cardiology",
issn = "0735-1097",
publisher = "Elsevier USA",
number = "2",

}

TY - JOUR

T1 - New percutaneous transluminal coronary angioscope

AU - Mizuno, Kyoichi

AU - Arai, Tsunenori

AU - Satomura, Kimio

AU - Shibuya, Toshio

AU - Arakawa, Ko

AU - Okamoto, Yasuhiro

AU - Miyamoto, Akira

AU - Kurita, Akira

AU - Kikuchi, Makoto

AU - Nakamura, Haruo

AU - Utsumi, Atsushi

AU - Takeuchi, Kiyoshi

PY - 1989

Y1 - 1989

N2 - A new percutaneous transluminal coronary angioscopic catheter has been developed for visualization of the coronary artery. A specially made balloon, fixed at the catheter tip, and an angulation mechanism made a precise coaxial alignment possible in the coronary lumen. This angioscopic catheter, 1.22 mm in outer diameter, has four channels, one for irrigation in which a 0.36 mm (0.014 in.) angioplasty guide wire can be used. With the use of this angioscope, coronary lumens in 8 dogs, thrombi that were produced with copper coils in the left anterior descending coronary artery in 11 dogs, atherosclerotic coronary arteries in 20 patients during cardiac catheterization and the sequence of transluminal coronary angioplasty in 1 patient were observed. The angioscopic catheter was introduced into the coronary artery by an 8F guide catheter. The steerable guide wire enabled the angioscopic catheter to be accurately and safely inserted into the target lesion in all cases. The inflated balloon and angulation mechanism allowed a curved coronary lumen and atheroma to be seen with a limited volume of irrigation fluid. Visualization was good (complete visualization of the inner lumen) in 46% (10 of 22 lesions), moderate (visualization of >50% of the inner lumen) in 36% (8 of 22 lesions) and poor (visualization of <50% of the inner lumen) in 18% (4 of 22 lesions) in humans. There were no major complications. These preliminary experiences in closed chest cardiac catheterization in dogs and in humans indicate the feasibility of this angioscope. The information yielded by angioscopy may be clinically useful in the study of the pathophysiologic changes in coronary disease that are not detected by coronary arteriography.

AB - A new percutaneous transluminal coronary angioscopic catheter has been developed for visualization of the coronary artery. A specially made balloon, fixed at the catheter tip, and an angulation mechanism made a precise coaxial alignment possible in the coronary lumen. This angioscopic catheter, 1.22 mm in outer diameter, has four channels, one for irrigation in which a 0.36 mm (0.014 in.) angioplasty guide wire can be used. With the use of this angioscope, coronary lumens in 8 dogs, thrombi that were produced with copper coils in the left anterior descending coronary artery in 11 dogs, atherosclerotic coronary arteries in 20 patients during cardiac catheterization and the sequence of transluminal coronary angioplasty in 1 patient were observed. The angioscopic catheter was introduced into the coronary artery by an 8F guide catheter. The steerable guide wire enabled the angioscopic catheter to be accurately and safely inserted into the target lesion in all cases. The inflated balloon and angulation mechanism allowed a curved coronary lumen and atheroma to be seen with a limited volume of irrigation fluid. Visualization was good (complete visualization of the inner lumen) in 46% (10 of 22 lesions), moderate (visualization of >50% of the inner lumen) in 36% (8 of 22 lesions) and poor (visualization of <50% of the inner lumen) in 18% (4 of 22 lesions) in humans. There were no major complications. These preliminary experiences in closed chest cardiac catheterization in dogs and in humans indicate the feasibility of this angioscope. The information yielded by angioscopy may be clinically useful in the study of the pathophysiologic changes in coronary disease that are not detected by coronary arteriography.

UR - http://www.scopus.com/inward/record.url?scp=0024589301&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0024589301&partnerID=8YFLogxK

U2 - 10.1016/0735-1097(89)90513-5

DO - 10.1016/0735-1097(89)90513-5

M3 - Article

C2 - 2521505

AN - SCOPUS:0024589301

VL - 13

SP - 363

EP - 368

JO - Journal of the American College of Cardiology

JF - Journal of the American College of Cardiology

SN - 0735-1097

IS - 2

ER -