Numerical analysis for the thermal ageing effect on fracture behaviors of CF8A pipes and piping systems under monotonic and very low cycle fatigue loading conditions

Gyo Geun Youn, Hyun Suk Nam, Yun Jae Kim

Research output: Contribution to journalConference article

Abstract

In this research, the effect of thermal ageing for CF8A is studied under displacement-controlled low cycle fatigue. Virtual tests of pipe and pipe system are considered and they have the same shape and loading conditions as the pipe and pipe systems tested in Battelle. Only material was changed from A106 Gr. B to CF8A. The pipe tests are four-point bending tests with three different load ratio (R= -1, 0, 1) having through-wall crack. The pipe system test also has through wall crack with seismic loading condition (PGA=1g). To simulate the cyclic loading and thermal ageing effect, multi-axial fracture strain energy based FE damage model and thermal ageing constant "C" was applied. From the simulation, it can be known from the virtual pipe test that crack growth rates of unaged and aged CF8A become similar when loading type is changed from monotonic to cyclic. Also, it is can be known from the virtual pipe system test that the crack growths of unaged and aged CF8A are almost same when the size of through-wall crack is 43.2 o . However, the crack growth of unaged CF8A is almost 25% smaller that aged CF8A when the size of through-wall crack is 90 o .

Original languageEnglish
Pages (from-to)1305-1311
Number of pages7
JournalProcedia Structural Integrity
Volume13
DOIs
Publication statusPublished - 2018 Jan 1
Externally publishedYes
Event22nd European Conference on Fracture, ECF 2018 - Belgrade, Serbia
Duration: 2018 Aug 252018 Aug 26

Fingerprint

Thermal aging
Piping systems
Numerical analysis
Pipe
Fatigue of materials
Cracks
Crack propagation
Prostaglandins A
Bending tests
Strain energy

Keywords

  • Separated by semicolons
  • Type your keywords here

ASJC Scopus subject areas

  • Mechanical Engineering
  • Mechanics of Materials
  • Civil and Structural Engineering
  • Materials Science(all)

Cite this

@article{860428d5339a450db80e93143eb87425,
title = "Numerical analysis for the thermal ageing effect on fracture behaviors of CF8A pipes and piping systems under monotonic and very low cycle fatigue loading conditions",
abstract = "In this research, the effect of thermal ageing for CF8A is studied under displacement-controlled low cycle fatigue. Virtual tests of pipe and pipe system are considered and they have the same shape and loading conditions as the pipe and pipe systems tested in Battelle. Only material was changed from A106 Gr. B to CF8A. The pipe tests are four-point bending tests with three different load ratio (R= -1, 0, 1) having through-wall crack. The pipe system test also has through wall crack with seismic loading condition (PGA=1g). To simulate the cyclic loading and thermal ageing effect, multi-axial fracture strain energy based FE damage model and thermal ageing constant {"}C{"} was applied. From the simulation, it can be known from the virtual pipe test that crack growth rates of unaged and aged CF8A become similar when loading type is changed from monotonic to cyclic. Also, it is can be known from the virtual pipe system test that the crack growths of unaged and aged CF8A are almost same when the size of through-wall crack is 43.2 o . However, the crack growth of unaged CF8A is almost 25{\%} smaller that aged CF8A when the size of through-wall crack is 90 o .",
keywords = "Separated by semicolons, Type your keywords here",
author = "Youn, {Gyo Geun} and Nam, {Hyun Suk} and Kim, {Yun Jae}",
year = "2018",
month = "1",
day = "1",
doi = "10.1016/j.prostr.2018.12.275",
language = "English",
volume = "13",
pages = "1305--1311",
journal = "Procedia Structural Integrity",
issn = "2452-3216",

}

TY - JOUR

T1 - Numerical analysis for the thermal ageing effect on fracture behaviors of CF8A pipes and piping systems under monotonic and very low cycle fatigue loading conditions

AU - Youn, Gyo Geun

AU - Nam, Hyun Suk

AU - Kim, Yun Jae

PY - 2018/1/1

Y1 - 2018/1/1

N2 - In this research, the effect of thermal ageing for CF8A is studied under displacement-controlled low cycle fatigue. Virtual tests of pipe and pipe system are considered and they have the same shape and loading conditions as the pipe and pipe systems tested in Battelle. Only material was changed from A106 Gr. B to CF8A. The pipe tests are four-point bending tests with three different load ratio (R= -1, 0, 1) having through-wall crack. The pipe system test also has through wall crack with seismic loading condition (PGA=1g). To simulate the cyclic loading and thermal ageing effect, multi-axial fracture strain energy based FE damage model and thermal ageing constant "C" was applied. From the simulation, it can be known from the virtual pipe test that crack growth rates of unaged and aged CF8A become similar when loading type is changed from monotonic to cyclic. Also, it is can be known from the virtual pipe system test that the crack growths of unaged and aged CF8A are almost same when the size of through-wall crack is 43.2 o . However, the crack growth of unaged CF8A is almost 25% smaller that aged CF8A when the size of through-wall crack is 90 o .

AB - In this research, the effect of thermal ageing for CF8A is studied under displacement-controlled low cycle fatigue. Virtual tests of pipe and pipe system are considered and they have the same shape and loading conditions as the pipe and pipe systems tested in Battelle. Only material was changed from A106 Gr. B to CF8A. The pipe tests are four-point bending tests with three different load ratio (R= -1, 0, 1) having through-wall crack. The pipe system test also has through wall crack with seismic loading condition (PGA=1g). To simulate the cyclic loading and thermal ageing effect, multi-axial fracture strain energy based FE damage model and thermal ageing constant "C" was applied. From the simulation, it can be known from the virtual pipe test that crack growth rates of unaged and aged CF8A become similar when loading type is changed from monotonic to cyclic. Also, it is can be known from the virtual pipe system test that the crack growths of unaged and aged CF8A are almost same when the size of through-wall crack is 43.2 o . However, the crack growth of unaged CF8A is almost 25% smaller that aged CF8A when the size of through-wall crack is 90 o .

KW - Separated by semicolons

KW - Type your keywords here

UR - http://www.scopus.com/inward/record.url?scp=85064648848&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85064648848&partnerID=8YFLogxK

U2 - 10.1016/j.prostr.2018.12.275

DO - 10.1016/j.prostr.2018.12.275

M3 - Conference article

AN - SCOPUS:85064648848

VL - 13

SP - 1305

EP - 1311

JO - Procedia Structural Integrity

JF - Procedia Structural Integrity

SN - 2452-3216

ER -