On-site monitoring system for hazardous air pollutants using an adsorption-thermal desorption-capillary GC system equipped with a photoionization detector and an electrolytic conductivity detector

Tsuneaki Maeda, Kaoru Funaki, Yoshifumi Yanaguchi, Kouji Ichioka, Koji Suzuki, Noriko Yamamoto, Masatoshi Morita

Research output: Contribution to journalArticle

7 Citations (Scopus)
Original languageEnglish
Pages (from-to)471-474
Number of pages4
JournalHRC Journal of High Resolution Chromatography
Volume21
Issue number8
DOIs
Publication statusPublished - 1998

Fingerprint

Volatile Organic Compounds
Air Pollutants
Photoionization
Thermal desorption
Volatile organic compounds
Detectors
Adsorption
Monitoring
Air

Keywords

  • Adsorption/thermal desorption sampling instrument
  • Capillary gas chromatography
  • Electrolytic conductivity detector
  • Environmental air monitoring
  • Hazardous air pollutants
  • Photoionization detector
  • Volatile organic compounds

ASJC Scopus subject areas

  • Chemical Engineering(all)

Cite this

On-site monitoring system for hazardous air pollutants using an adsorption-thermal desorption-capillary GC system equipped with a photoionization detector and an electrolytic conductivity detector. / Maeda, Tsuneaki; Funaki, Kaoru; Yanaguchi, Yoshifumi; Ichioka, Kouji; Suzuki, Koji; Yamamoto, Noriko; Morita, Masatoshi.

In: HRC Journal of High Resolution Chromatography, Vol. 21, No. 8, 1998, p. 471-474.

Research output: Contribution to journalArticle

Maeda, Tsuneaki ; Funaki, Kaoru ; Yanaguchi, Yoshifumi ; Ichioka, Kouji ; Suzuki, Koji ; Yamamoto, Noriko ; Morita, Masatoshi. / On-site monitoring system for hazardous air pollutants using an adsorption-thermal desorption-capillary GC system equipped with a photoionization detector and an electrolytic conductivity detector. In: HRC Journal of High Resolution Chromatography. 1998 ; Vol. 21, No. 8. pp. 471-474.
@article{bffd4ab46d094f95a6e3b775f5a7d111,
title = "On-site monitoring system for hazardous air pollutants using an adsorption-thermal desorption-capillary GC system equipped with a photoionization detector and an electrolytic conductivity detector",
keywords = "Adsorption/thermal desorption sampling instrument, Capillary gas chromatography, Electrolytic conductivity detector, Environmental air monitoring, Hazardous air pollutants, Photoionization detector, Volatile organic compounds",
author = "Tsuneaki Maeda and Kaoru Funaki and Yoshifumi Yanaguchi and Kouji Ichioka and Koji Suzuki and Noriko Yamamoto and Masatoshi Morita",
year = "1998",
doi = "10.1002/(SICI)1521-4168(19980801)21:8<471::AID-JHRC471>3.0.CO;2-7",
language = "English",
volume = "21",
pages = "471--474",
journal = "Journal of Separation Science",
issn = "1615-9306",
publisher = "Wiley-VCH Verlag",
number = "8",

}

TY - JOUR

T1 - On-site monitoring system for hazardous air pollutants using an adsorption-thermal desorption-capillary GC system equipped with a photoionization detector and an electrolytic conductivity detector

AU - Maeda, Tsuneaki

AU - Funaki, Kaoru

AU - Yanaguchi, Yoshifumi

AU - Ichioka, Kouji

AU - Suzuki, Koji

AU - Yamamoto, Noriko

AU - Morita, Masatoshi

PY - 1998

Y1 - 1998

KW - Adsorption/thermal desorption sampling instrument

KW - Capillary gas chromatography

KW - Electrolytic conductivity detector

KW - Environmental air monitoring

KW - Hazardous air pollutants

KW - Photoionization detector

KW - Volatile organic compounds

UR - http://www.scopus.com/inward/record.url?scp=0031714926&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0031714926&partnerID=8YFLogxK

U2 - 10.1002/(SICI)1521-4168(19980801)21:8<471::AID-JHRC471>3.0.CO;2-7

DO - 10.1002/(SICI)1521-4168(19980801)21:8<471::AID-JHRC471>3.0.CO;2-7

M3 - Article

AN - SCOPUS:0031714926

VL - 21

SP - 471

EP - 474

JO - Journal of Separation Science

JF - Journal of Separation Science

SN - 1615-9306

IS - 8

ER -